Error table
SHARKY 775
SHARKY 775 / SCYLAR INT 8
Error
C-1
E1
E3
E4
E5
E6
E7
E8
E9
EA
Eb
EC
Ed
Error table
SCYLAR INT 8
Error
C-1
E1
E3
E5
E8
E9
EA
Eb
EC
Ed
-48-
Error description
Basic parameters saved in flash or RAM
have been lost
Temperature range exceeds
(-9.9 °C ... 190 °C)
Cause, Remedy
Replace meter
Error description
Basic parameters saved in flash or RAM
have been lost
Temperature range exceeds
(-9.9 °C ... 190 °C)
Cause, Remedy
Replace meter
Sensor short-circuit, sensor
break
Replace sensor
Forward and return sensor reversed
Interchange forward and return
sensor
Hardware error
Transducer defective or
short-circuit
Communication not possible
Too frequent reading
Increase interval for maximum
values (see "Interval of maximum values" on page 35)
Flow direction of flow meter incorrect
Flow rate = 0
Check installation position and
ensure correct installation
No meaningful ultrasonic receive signal Air in the measuring path
Defective primary voltage (only if mains Check primary voltage and enunit used)
sure supply
Supply from backup battery
Battery nearly discharged
Replace meter
Leakage: Burst pipe detected
Check pipes and connections,
repair if necessary
Leakage: Heat meter leak detected
Check meter, replace if necessary
Leakage: Leakage pulse input 1
Check pulse input 1 and repair
leakage if necessary
Leakage: Leakage pulse input 2
Check pulse input 2 and repair
leakage if necessary
Sensor short-circuit, sensor
break
Replace sensor
Forward and return sensor reversed
Interchange forward and return
sensor
Communication not possible
Too frequent reading
Increase interval for maximum
values (see "Interval of maximum values" on page 35)
Defective primary voltage (only if mains Check primary voltage and enunit used) Supply from backup battery sure supply
Battery nearly discharged
Replace meter
Leakage: Burst pipe detected
Check pipes and connections,
repair if necessary
Leakage: Heat meter leak detected
Check meter, replace if necessary
Leakage: Leakage pulse input 1
Check pulse input 1 and repair
leakage if necessary
Leakage: Leakage pulse input 2
Check pulse input 2 and repair
leakage if necessary