3 SPECIFICATIONS MELSEC-Q (c) When the trouble code = 0200H For a slave trouble information occurrence (error code = 0200H), the slave trouble information is stored in the detailed data. The communication trouble area configuration for this case is shown below. In addition, the expansion communication trouble information is stored in buffer memory 2096 to 2110 for only the latest trouble information of the error code = 0200H trouble information. For information regarding the expansion communication trouble information refer to Section 3.4.2 (6). Error code = slave trouble information occurrence Detailed data length = 3 Detailed data 1 Master address ( 1) Slave address ( 2) Detailed data 2 Trouble information Detailed data 3 Slave ID ( 3) 1 The station address of the master station that controls the slave station in which this trouble information occurred is stored. However, FFH is stored when the trouble information shows the exchange with the slave is failed. 2 The station address of the slave station in which this trouble information occurred is stored. 3 Individual slave inherent ID No. from the PNO is stored. However, FFH is stored for trouble information that shows that the exchange with the slave failed. The trouble information is shown in a 16-bit bit string, and the bits that correspond to the respective trouble occurrences are set. A description of the error information is given below. bit Description 15 Controlled by another master. 14 The parameter transmitted by the master is incorrect. The response from the slave is incorrect. The function requested by the master is not supported. Expansion trouble information exists. The I/O byte size parameter received from the master does not match that of the slave. The slave is not ready to exchange. 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Communication state Multiple masters are trying to communicate with the same slave, so recheck the parameter. Check the parameter. Check the slave or network status. Check the slave specifications. Especially if global control is supported. Check the slave status. (refer to Section 3.4.2 (6).) Check the slave parameter. Exchange with the slave cannot be conducted. Separated from the cyclic exchange by the parameter setting. 0 (reserved) The slave has entered the SYNC mode. The slave has entered the FREEZE mode. Watchdog monitoring is being conducted in the slave. 0 (fixed) Diagnostic data read request. Parameter allocation request from a slave. Processing This trouble information will always occur at exchange start, so it can be ignored. If this trouble occurs during exchange, check the slave status and communication circuit. Check the slave status and communication circuit. And check the parameter. This trouble information will always occur at exchange start, so it can be ignored. Check if the parameter on the network was changed by a class 2 master. (Normal operation) (Normal operation) (Normal operation) Setting station Master Slave Master Slave Master Slave Slave Master Master Slave Slave Slave Slave Slave Check the slave statue. Slave This error information will always occur at exchange start, so Slave it can be ignored. If this error occurs during exchange, check the slave status and communication circuit. : Exchange continues even if trouble occurs. 3 - 24 3 - 24