F221 F221 RX Torque Reference Setpoint #2 Direct Access Number — F221 Program ⇒ Torque Setting Parameters ⇒ Setpoints ⇒ RX Parameter Type — Numerical Factory Default — 100.00 This parameter is used to set the gain and bias of the RX input terminal when the RX terminal is used as the control input while operating in the Torque Control mode. This is accomplished by establishing an associated V/f output pattern for a given RX input level. Changeable During Run — Yes Minimum — -250.00 Maximum — 250.00 Units — % See RX Speed Reference #1 for further information on this setting. This parameter sets RX Torque Reference Setpoint #2 and is the output torque value that is associated with setting of RX Speed Reference #2 while operating in the Torque control mode. HX7 ASD Programming and Operation Manual 83