Transcript
PA-4000 User Manual Ch2: Rev.1-1/05 2. Tutorials This chapter presents tutorials on electroporation and the various types of equipment used in the electroporation field. 2.1 Electroporation Electroporation is the name for the use of a trans-membrane electric field pulse to induce an effective state of poration in a bio-membrane. The pores formed by this process are commonly called electropores. Their presence allows molecules, ions, and water to pass from one side of the membrane to the other. As Figure 2-1 shows, the electropores are located primarily on the surfaces of cells that are closest to the electrodes. If the electric field pulse has the proper parameters, then the ‘’electroporated’’ E cells can recover (the electropores reseal spontaneously) and cells will continue to grow and express their genetic material. + - A B Figure 2-1: Electropores The use of electroporation became very popular through the 1980s because it was found to be an exceptionally practical way to place drugs, genetic material (e.g., DNA), or other molecules into cells. In the late 1980s, scientists began to use electroporation protocols with multi-cellular tissue as well as cell suspensions. Total Pore Area Though cell-to-cell biological variability causes some cells to be more sensitive to electroporation than other cells, pore formation, number, and effective diameter is generally a function of the product of the pulse amplitude and the pulse duration (Figure 2-2). In order for pores to form, this product has to be above a threshold. In Figure 2-2 lines ‘’A’’ and ‘’B’’ identify thresholds where pore formation begins. Additionally, pore number and effective pore diameter increase with the product of pulse amplitude and pulse duration. Although other factors are involved, this threshold is now understood to be largely dependent on the reciprocal of cell size. If the upper limit threshold is reached (lines ‘’C’’ and ‘’D’’), pore diameter and total pore area become too large for the cell to repair by any spontaneous or biological process. Therefore the cell is irreversibly damaged. To prevent this damage, pulse protocols are empirically developed to be at some point above threshold and below lethality. Since the mechanism of electroporation is not well understood, the development of protocols for a particular application to a previously uncharacterized cell or tissue have usually been achieved by empirically adjusting pulse parameters such as amplitude, duration, number, and inter-pulse interval. A B C D Pulse Amplitude x Pulse Duration Initial Pulse Figure 2-2: Pore Area Cyto Pulse Sciences, Inc., P. O. Box 609, Columbia, MD 21045 USA 410-787-1890 2-1