Download FlexTest SE Controller Service
Transcript
Cabling Model 493.42 System I/O Connections J54 Digital Inputs Connector J54 Dig In accommodates up to three digital signals from external devices. You can use digital input signals to trigger test events with your controller applications. • All of the inputs are optically isolated. • Channel inputs can be 3 volts (minimum) and 26 volts (maximum) from an external voltage source. . J54 Connector Pin Assignments NAME PIN 1 dig in 24V 24 V through 6.6K resistor 2 dig in 1 high High side of opto-isolator (opto on = logic 1) 3 dig in 1 low Low side of opto-isolator 4 dig in 2 high High side of opto-isolator (opto on = logic 1) 5 dig in 2 low Low side of opto-isolator 6 dig in 3 high High side of opto-isolator (opto on = logic 1) 7 dig in 3 low Low side of opto-isolator 8 dig in com 24V common 9 dig in com 24V common Cable specification 68 FUNCTION The cabling information shown assumes a single cable destination (with an overall shield). In other applications, the cable may have more than one destination. For these applications an overall shield is not practical and non-EMI connectors and back shells are permissible. • 9 pin contact type D male EMI connector • Back shell–EMI metallized plastic • Cable–shielded twisted pairs as required (24 AWG minimum) with drain wire(s) connected to the metallized backshell at the chassis. Model 493.02 Controller Service