Model 6220/6221 Reference Manual Delta, Pulse Delta, and Differential Conductance 5-19 Table 5-2 (cont.) Error/status codes and messages +411 Diff. Conductance step Occurs if two adjacent Diff Reduce the number of steps by Conductance values use the same increasing the step size or widen error source value. The algorithm to cal- the start-step interval. culate Diff. Cond. voltage divides by zero and generates a NAN (not a number) reading (+9.9e37). This error does not abort the test but does indicate that corrupt data has been acquired. +412 Diff. Conductance upranged The Model 6221 selects the BEST range based on the set start, stop, and step parameters. For example, if start is -20µA, stop is +20µA, and step is 1µA, the Model 6221 will select the 20µA source range. If using a Delta value that will cause the last output value to exceed 21µA, the next higher range will be selected during the arming process. This is not an error. It is only an indication that a source uprange has occurred during the arming process. +416 Step size too small Differential Conductance – Occurs if the step size is so small, it rounds down to zero. An actual step size of zero would result in a test that would never finish. Use an actual step size that does not get rounded to zero. Avoid using repeat filter that has a large filter count. Also avoid using a small start-to-stop span. When using the repeat averaging filter, the actual step size is the user entered step size value divided by the filter count value. This error occurs during the arming process. Differential Conductance will not arm. +419 Trigger Link cable not connected This error occurs during the arm process. Make sure the Trigger Link cable is properly connected. +809 Not Allowed with RS-232 Occurs when trying to :ARM Delta, Select a different interface and Pulse Delta or Differential Conduc- then arm Delta, Pulse Delta, or tance with the RS-232 interface Differential Conductance. selected for the Model 622x. Return to Section 5 topics
Related documents
Model 6220 DC Current Source Model 6221 AC and DC Current
Christie CP2000-X User manual
Model 2182/2182A Nanovoltmeter
BodyMedia FIT Operating instructions
Manual - Test Equipment Depot
Christie CP2000 User Manual
Waveforms - Artisan Technology Group
Model 2520Pulsed Laser Diode Test System User`s Manual
AT-1 / AT-1smartprint ECG unit
AEMC Model 6550 Megohmmeter Manual PDF
Models 2500 And 2502 Dual Photodiode Meter User`s Manual
USER`S MANUAL