Download Synergy Manager User Manual - Rev S
Transcript
Synergy Manager Operating Instructions Rev S 4.6 9/15/2008 Watlow F4 Controller (WF4) A Dual Channel Controller Hardware Revision, V2.10. Communication Support Method External Hardware Needed Protocol RS232 GPIB/IEEE-488 Synergy488-GPIB Synergy488-RS232 Synergy488-TCP/IP Synergy Gateway-Ethernet 5 Synergy488-GPIB_MD 5 Synergy488-RS232_MD 5 Synergy488-TCP/IP_MD PC Comm. Port ICS 4804A / 09A,Prom Rev. 4809 R13 or Later Synergy488 Module with TE1579 Rev. 4.1 or Later firmware Synergy488 Module with TE1579 Rev. 4.1 or Later firmware Synergy488 Module with TE1579 Rev. 4.1 or Later firmware Synergy Gateway Module Synergy488 Module with TE1579 Rev. 5.1 or Later firmware Synergy488 Module with TE1579 Rev. 5.1 or Later firmware Synergy488 Module with TE1579 Rev. 5.1 or Later firmware Modbus GPIB GPIB Modbus/RS485 TCP/IP Modbus TCP RS485 Network RS485 Network RS485 Network Application Modes Full Feature Monitor Only Description Process Data SP1 SP2 C1 C2 Temperature Mode Heating / Cooling Humidity / Dehumidify Events Controller Alarms Read/Write Read/Write Read Only Read Only Read/Write Read Only Read Only Read/Write Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Channel 1 Set Point Channel 2 Set Point Channel 1 Process Variable Channel 2 Process Variable Celsius and Fahrenheit selectable PID Display PID Display Event Output Display Controller Alarm Alert Yes Yes Yes Yes Yes Yes Application Limit Check Setup Application Deviatioin Check Setup Alarms Check Setup Saving Yes Yes Yes Yes Yes Yes Yes Yes Graph process and set point data Log process and set point data Exports log data as CSV Data File Logging of external UUT data NA Yes Yes Yes NA NA Yes Yes Yes NA Temperature only mode Temperature / Temperature mode Temperature / Humidity mode Temperature / Pressure (Altitude) mode Temperature / Vibration mode Yes Yes Yes Yes NA NA Create controller profile Download to controller Start and Stop profiles 1 Yes Yes Yes Yes Yes NA Yes Yes Yes Yes Yes Controller Profile DownLoad location WF4 Autostart Step WF4 Ramp Time Step WF4 Soak Step WF4 Jump Step WF4 End Step Application Setting Limit Check Setup Deviation Check Setup Limit Check Setup Saving Data Logging Graph/Zoom Process Variable 1 Export Data UUT Data Logging 3 Controller Modes Temperature Only Temperature / Temperature Temperature / Humidity Temperature / Pressure (Altitude) Temperature / Vibration (HALT / HASS) Profiles 2,4,5,6 Profile Creation Profile Download 6 Profile Control Profile Editor Support Profile Download File 4 AutoStart Step Ramp Step Hold Step Jump Step Stop Step 2,4,5,6 154