DET NORSKE VERITAS Report No: 2005-3246, rev. 01 TECHNICAL REPORT Clause Requirement - test intruder alarm conditions Result Verdict IAS zone response time measured to be approximately 50ms < 400ms. NX-4: IAS zone response time measured to be approximately 50ms < 400ms. NX-216: IAS zone response time measured to be approximately 285ms < 400ms. Intruder alarm messages are being processed as intruder alarm conditions = OK 8.9.2 Hold-up signals or messages • 400mS • Hold-up messages shall be processed as hold-up alarm conditions NX-4/6/8: P IAS zone response time measured to be approximately 50ms < 400ms. NX-216: IAS zone response time measured to be approximately 285ms < 400ms. Hold-up alarm messages are being processed as hold-up alarm conditions = OK 8.9.3 Tamper signals or messages • 400mS • Tamper messages shall be processed as tamper alarm conditions NX-4/6/8: P IAS zone response time measured to be approximately 50ms < 400ms. NX-216: IAS zone response time measured to be approximately 285ms < 400ms. Tamper alarm messages are being processed as tamper alarm conditions = OK Page 28 Reference to part of this report which may lead to misinterpretation is not permissible. 2005-3246 final.doc