Download WinCC flexible 2008 Communication Part 1 - Internet
Transcript
Appendix 9.1 System alarms 80000 - Archive alarms Number Effect/causes Remedy 80001 The log specified is filled to the size defined (in percent) and must be stored elsewhere. Store the file or table by executing a ‘move’ or ‘copy’ function. 80002 A line is missing in the specified log. -- 80003 The copying process for logging was not successful. In this case, it is advisable to check any subsequent system alarms, too. -- 80006 Since logging is not possible, this causes a permanent loss of the functionality. In the case of databases, check whether the corresponding data source exists and start up the system again. 80009 A copying action has been completed successfully. -- 80010 Since the storage location was incorrectly entered in WinCC flexible, this causes a permanent loss of the functionality. Configure the storage location for the respective log again and restart the system when the full functionality is required. 80012 Log entries are stored in a buffer. If the values are read to the buffer faster than they can be physically written (using a hard disk, for example), overloading may occur and recording is then stopped. Archive fewer values. Or: Increase the logging cycle. 80013 The overload status no longer applies. Archiving resumes the recording of all values. -- 80014 The same action was triggered twice in quick succession. Since the process is already in operation, the action is only carried out once. -- 80015 This system alarm is used to report DOS or database errors to the user. -- 80016 The logs are separated by the system function "CloseAllLogs" and the incoming entries exceed the defined buffer size. All entries in the buffer are deleted. Reconnect the logs. 80017 The number of incoming events cause a buffer overflow. This can be caused, for example, by several copying actions being activated at the same time. All copy jobs are deleted. Stop the copy action. 80019 The connection between WinCC flexible and all -logs were closed, for example, after executing the system function "CloseAllLogs". Entries are written to the buffer and are then written to the logs when a connection is re-established. There is no connection to the storage location and the storage medium may be replaced, for example. 80020 The maximum number of simultaneously copy operations has been exceeded. Copying is not executed. Wait until the current copying actions have been completed, then restart the last copy action. 80021 An attempt was made to delete a log which is still busy with a copy action. Deletion has not been executed. Wait until the current copying actions have been completed, then restart the last action. WinCC flexible 2008 Communication Part 1 User's Manual, 07/2008, 6AV6691-1CA01-3AB0 249