Download SILVERMAX COMMANDS
Transcript
Initialization Commands MAXIMUM TEMPERATURE TRIP (MTT) Description: Sets the temperature at which SilverMax will shut down the motor. This is used to prevent internal over-heating of the motor electronics. The value is entered in degrees Celsius integer units. (Example “70” for 70 degrees Celsius). The maximum temperature error condition is OR-ed with the motor driver over temperature condition. Either active will cause an Over Temperature status condition in the Internal Status Word. The temperature can be read using the ANALOG READ INPUT command. Command Info: Command Name Maximum Temperature Trip (MTT) Command Type Program (Class “D”) Example: Command Code (Hex) 214 (0xD6) Parameter Range (Hex) <Temperature> Temperature in °C 0 = Don’t Check 1 to 70 (1 to 0x46) [2 Words] QuickControl Example: Set Motor to give an error at 70 degrees C @16 214 70 (CR) SilverMax Response: ACK only Response Example: * 10 (CR) SilverMax Command Reference Command Parameters Page 62