Download R&S®ESPI Operating Manual
Transcript
R&S ESPI Instrument Functions Analyzer Mode NEXT MIN The NEXT MIN softkey sets the active marker/delta marker to the next higher minimum of the selected trace. Remote command: NEXT MIN RIGHT The NEXT MIN RIGHT softkey sets the active marker/delta marker to the next higher minimum right of the current marker position on the selected trace. Remote command: NEXT MIN LEFT CALC:MARK:MIN:LEFT CALC:DELT:MIN:LEFT The EXCLUDE LO softkey limits the frequency range for the marker search functions or disables the limit. activated Because of the feed through of the first local oscillator to the first intermediate frequency at the input mixer, the LO is represented as a signal at 0 Hz. To avoid the marker jumping to the LO at 0 Hz with the peak function when setting the display range, this frequency is excluded. The minimum frequency to which the marker jumps, is ≥ 6 × resolution bandwidth (RBW). deactivated No restriction to the search range. The frequency 0 Hz is included in the marker search functions. Remote command: PEAK EXCURSION CALC:MARK:MIN:RIGH CALC:DELT:MIN:RIGH The NEXT MIN LEFT softkey sets the active marker/delta marker to the next higher minimum left of the current marker position on the selected trace. Remote command: EXCLUDE LO CALC:MARK:MIN:NEXT CALC:DELT:MIN:NEXT CALC:MARK:LOEX ON The PEAK EXCURSION softkey enables – for level measurements – the entry of a minimum level value by which a signal must rise or fall so that it will be identified as a maximum or a minimum by the NEXT PEAK and NEXT MIN search functions. Valid entries are from 0 dB to 80 dB; the resolution is 0.1 dB. Remote command: CALC:MARK:PEXC 10dB The default setting for the peak excursion is 6 dB. This value is sufficient for the NEXT PEAK and NEXT MIN functions since, in this mode, the next lower maximum or next higher minimum will always be detected. If NEXT PEAK LEFT or NEXT PEAK RIGHT is selected, these functions search for the next relative maximum left or right of the current marker position irrespective of the current signal amplitude. Relative maximum is understood to mean a decrease of the signal amplitude by a defined value – i.e. the peak excursion – right and left of the amplitude peak. The 6 dB level change set as a default value may be attained already by the inherent noise of the instrument. In such a case, the R&S ESPI would identify noise peaks as maxima or minima. The value entered for the PEAK EXCURSION should therefore be higher than the difference between the highest and the lowest value measured for the displayed inherent noise. The following example illustrates the effect of different settings of the PEAK EXCURSION. Operating Manual 1164.6607.12 - 02 4.133
Related documents
R&S®FSG Operating Manual
FSQ Operating Manual English FW 4.55
R&S ESR EMI Test Receiver User Manual
R&S®FSQ User Manual - Rohde & Schwarz Colombia
Note - MATsolutions
R&S®FSU Operating Manual
R&S ESR EMI Test Receiver - Rohde & Schwarz Middle East and
R&S®FSP Operating Manual
R&S FSV-K54 EMI Measurement Application User Manual
HP 8970B Option 020 Service Manual Supplement
R&S FSV-K54 EMI Measurement Application User Manual
R&S