Di850 Solution ID Controller - no or slow print, scan failure, garbled data, lockup TAUS0703272EN* Solution Usage Description Unable to print with the three-hole punch option selected. All print jobs punch with two holes. Solution CAUSE: Three-hole punch is not selected in memory switches. SOLUTION: Perform the following procedure to enable three-hole punching: 1. Press the HELP key. 2. Press Key Operator Mode. 3. Press the down arrow and select #13 Memory Switches. 4. Scroll to memory switch #46. 5. Press Change to select 2 or 4 hole punch. SPECIAL NOTE : Solution contribution by Mark D'Attilio, Production Print/SSD Copyright 2009, Konica Minolta Business Solutions U.S.A., Inc. June 2009 3