5. GPO Connector
A subD 15 pin socket provides a general purpose connection with 7 general purpose
opto-isolated outputs. The connections must be wired according to the following
diagram:
PIN
1
2
3
4
5
6
7
SIGNAL
Output 1
Output 2
Output 3
Output 4
Output 5
Output 6
Output 7
PIN
9
10
11
12
13
14
15
SIGNAL
GND1
GND2
GND3
GND4
GND5
GND6
GND7
Technical specifications
Icmax = 50 mA.
Vcemax= 70 V ; Vecmax = 7 V.
Pmax = 150 mW.
6. Alarm Relay Reset switch
There is a switch on the frontal panel to reset the alarm relay located on the rear
panel. The switch only has effect if the alarm condition is finished.
7. Indicators on the Control Module
The control module has three LEDs on its front panel.
S
LAN
M
24
Status of the Control Card:
Green: Ok
Red: Not Ok.
Status of the Ethernet
connection:
Green: Connected to LAN.
Red: No connection.
Not used.