Programming masks Objective: To describe the basic uses and programming of masks in the ControlKeeper system ControlKeeper masks Masks change the way a switch or analog input works during a specified time of day. Since masks are tied to a specific time of day, they will need maintenance if you change the schedule times. A single mask index record may be applied to any switch or analog input in the system. Mask types There are six mask types available. If a mask is not going to be used, please set this to ‘Not Used’. • • No Offs: OFF commands from the masked input will be ignored during the period when the mask is active. Please note that if the input’s timer is counting while the mask period begins and expires during the mask period, the timer’s OFF command will occur. To make sure that expired timers will not cause the lights to go off during this period you will also need to assign a No Timer mask. No Ons: All ON commands from the masked input will be ignored during the period when the mask is active. • Ignored: All commands from the masked input will be ignored during the period when the mask is active. The control panel acts as if the link between the input and the output has been removed during the period that the mask is active. • No Timer: When an input with a timer turns ON during the period that the mask is active or if the input timer times out during the period that the mask is active, no OFF command will be issued by the timer. • • p53 No Warn: If an input that initiates a warn turns OFF during the period that the mask is active, the OFF will cause an immediate OFF rather than waiting for the warning delay. If the input is turned OFF just prior to the start of the mask and the warn off timer starts counting down into the period that the mask is active, that warning will be issued. Re-evaluate: At the mask’s END TIME the ControlKeeper re-evaluates the current status of each relay that has been controlled by the masked input. The ControlKeeper determines the correct ON or OFF state for the relays based on the status of other inputs that are linked to it, and turns the relay ON or OFF based on that evaluation. The BEGIN TIME of the mask is irrelevant other than the fact that it must occur prior to the END TIME. Please note that if other masks are set up on the switch, they will take precedence over the RE-EVALUATE mask. For instance, if a NO OFFS mask is active at the REEVALUTE mask’s END TIME and the switch is OFF when the re-evaluation occurs, the off command from the switch will not be issued. Select/refresh the panel to program Before beginning programming steps in this section, be certain to select the correct panel to program or process a panel ‘refresh’ command to update any stale data on the display. Refer to “Before you begin” on page 9 for step-by-step instructions on these procedures. Configuring the mask: 1. From the ‘Main Menu’ display, select the ‘Masks’ menu. 2. Touch the mask index you wish to program. 3. Once the mask ‘Settings’ screen loads, touch the ‘Active’ field to place an ‘X’ in it. 4. If desired, select the ‘Mask Name’ field and use the keypad to type a new 8-character name. Select the ‘Accept’ button. 5. Touch the ‘Type’ field. Select the ‘desired mask type from the list.