Download Installation and operating instructions
Transcript
Operating mode, boiler status / Settings report, system parameters Operating mode Boiler status Boiler status 0 Standby 1 Emission test mode 2 Soft start 3 Heat demand (heating mode) 5 Heat demand with cycle block 6 Cycle block 7 Frost protection – heating 8 Soft start 11 DHW draw-off 12 DHW reheating 13 Minimum combi time 14 DHW quick start reheating 15 Cylinder mode 16 Frost protection – cylinder 17 Pump run-on – cylinder 18 Boil dry 19 dt output reduction 20 Parallel cylinder mode 21 Max. cylinder heating time exceeded 22 Sensor operating mode 2, contact closed 23 Sensor operating mode 3, contact closed Wolf recommends you complete the settings report carefully and to keep it safe to enable a quick solution to be found during service and in case of a full reset. Parameter A00 A01 A02 A03 A04 A05 A06 A07 A08 A09 A10 A11 A12 A13 60 Setting range Room influence 1 to 20 K / K Heat-up optimisation 0/1 Max. heat-up time 0 to 180 min Required heat-up time Adjusted outside temp. sensor 0 to 24 h Room sensor matching -5 to +5 K External room temp. sensor 0 to 1 Pasteurisation function 0 to 8 Service message 0 to 104 weeks Frost protection level -20 to +10 °C Parallel DHW operation 0/1 Room temperature-dependent OFF / ON summer/winter changeover Setback stop OFF, -39 to 0°C Minimum DHW temp. 0 to 60 °C Factory setting 4K/K 0 0 3h 0K 1 0 0 +2 °C 0 ON Individual setting - -16 °C 40 °C 30 61 872_0407