Download Tecumseh VSAG522ZXTHM Performance Data Sheet

Transcript
VSAG522ZXTHM
TPC___preliminary
October 14, 2011
Parts/Specifications
STANDARD
Unit BOM
Unit MODEL
32L5442-2E
VSAG522ZXTHM
Refrigeration RANGE
Design Pressure Low
Design Pressure High
Volts - HZ - Ph
Voltage Range
Min. Circuit Ampacity
Max. Fuse Size
-40°F to 10°F
181
450
200-230V 3~ 60HZ
180 - 253
24.52
40
Compressor MODEL
Compressor BOM
Compressor LRA
Compressor RLA
VSAG518ZXT
VS119RT-006-A4
153
16.41
OverLoad
Relay
Run Capacitor
Run Capacitor Rating
Start Capacitor
Start Capacitor Rating
Contactor
INTERNAL
Unit Drawing
Wiring no Fan controls
DGU1950-L302
WD23-2XT2L
91014B
OPTIONAL
Fan Motor
Fan Motor Qty
Fan Motor RLA
Fan Blade
Fan Guard
Shroud
810S186B40
2
1.9
51528-3
70832
70611-1
Adjustable Fan Ctrl (A)
LAFC-001
Defrost Timer (Tn)
LTCG-T2
Receiver Heater (R)
LHR-223
High Pressure switch
Low Pressure Control
Dual Pressure Conrol
84095-2L
84026-2
Solenoid Valve (S)
KSVC-285
Disconnect (D)
KDSG-601
Condenser
Head Master Valve
Check Valve
Process Valve
Liquid Valve
Suction Valve
50777-6
70107-1
56627
Receiver
Receiver Qty
Accumulator
Liquid Filter
Sight Glass
Suction Filter
51084
1
TK00044000
52000-164D
70084-2
70822-5S
CrankCase Heater
14947870
BOM INDEX DESCRIPTION
32xYYYY- 2ERA(F)TnDS
E Enclosure
R Receiver Heater
A Adjustable fan control
F Fixed fan Control
T1 Defrost timer option
T2 Defrost timer & Defrost Heaters Contactor
D Disconnect
S Solenoid liquid Valve (supplied loose)
31529-2
NOTES
IMPORTANT:
COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD
PROTECTOR. ALLOW TIME FOR RESET.
USE COPPER CONDUCTORS ONLY.
(EMPLOYER DES CONDUCTEUERS DE CUIVER
SEULEMENT.)
4
3
X
N
1
2
DEFROST CONTROL
RANCO
8145-xx
PRECISION 6145-xx
FAN 1
DEFROST
HEATERS
CONTACTOR COIL
FIELD WIRING NOTES
1.
ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL
APPLICABLE LOCAL AND NATIONAL CODES.
2. CONNECT INCOMING POWER LEADS FROM POWER SUPPLY
TO L1, L2, AND L3 IN COMPRESSOR CONTACTOR OR TO L1, L2 AND L3 IN
DISCONNECT SWITCH (IF PROVIDED). USE COOPER CONDUCTORS
ONLY. (EMPLOYER DES CONDUCTEURS DE CUIVER SEULEMENT.)
PROVIDE EQUIPMENT GROUNDING CONDUCTOR.
USE 75°C (MIN.) WIRING
3. DEFROST HEATERS LOADS SHOULD NOT BE HIGHER THEN THE
MAXIMUM HEATERS LOAD INDICATED ON THE UNIT LABEL.
DEFROST HEATERS TO BE CONTROLLED WITH A CONTACTOR AS SHOWN
ON THE DIAGRAM.
COMPRESSOR CONTACTOR
NC AUXILIARY SWITCH
FAN 2
GENERAL NOTES:
SOLENOID
LIQUID INJECTION
A. CONTACTOR COIL CIRCUIT IS FACTORY CONNECTED TO 230 V SOURCE IN
PANEL AS SHOWN
B. COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR.
ALLOW TIME FOR RESET.
COMPRESSOR CONTACTOR
NO AUXILIARY SWITCH
FC
COMPRESSOR
CONTACTOR COIL
see note A
HP
LP
FAN CONTROL
DT
LP
LOW PRESSURE CONTROL
TERMINAL
BOARD
P1
RECEIVER
HEATER
L2
L1
L3
T1
T3
F1
F2
HP
THERMOSTAT
HIGH PRESSURE SWITCH
POWER SUPPLY
208-230 / 60 / 3
L3
T3
L2
T2
L1
T1
DT
DISCHARGE LINE THERMOSTAT
FACTORY COMPONENTS
GRD
CRANK CASE
HEATER
COMPRESSOR
CONTACTOR
L1
L2
L3
T1
T2
T3
DEFROST
HEATERS
CONTACTOR
L1
L2
L3
T1
T2
T3
OPTIONAL FACTORY COMPONENTS
OPTIONAL FIELD COMPONENTS
BLACK
C
S
R
RED
YELLOW
CONDENSING UNIT WIRING, 230V 60Hz 3 Ph,
Liquid Injection Solenoid,
Fan control,
T1 & T2 defrost options
REL
REVISION
MAR. 11, 2011
COMPRESSOR
TERMINAL
WD23-2XT2L
L:\~ Andreea temp\ZZ Low Temp Scroll Datasheets\WORD_datasheets\Outdoor units\VSAG522ZXTHM_preliminary.doc
14/10/2011