SDM-300L3 Satellite Modem Remote Control Operation Receive Signal Level Status Command: Response: Revision 0 MN/SDM300L3.IOM <add/RSL_'cr' >add/RSL_xsnn.ndBm'cr''lf'] Where: x = < or > (data modifier to indicate that the receive signal level is less than or greater than the returned value). s = + or - (receive signal level sign, plus or minus). nn.n = 0.0 to 99.9 (receive signal level magnitude). Notes: 1. The 'x' (< or >) parameter is only returned if the level has exceeded the computational resolution of the system. 2. 'No Data' is returned if the level cannot be calculated. 3. Sampling' is returned if not enough data is currently available to calculate the level. Interface Buffer Fill Status LNB Current Monitor Status Command: Response: <add/IBFS_'cr' >add/IBFS_nn%'cr''lf'] Where: nn = 1 to 99 (relative to buffer depth). Command: Response: <add/LNBC_'cr' >add/LNBC_nnn'cr''lf'] Where: nnn = 0 to 500 (in 1 mA steps) ODU Current Monitor Status Command: Response: <add/ODUC_'cr' >add/ODUC_nnnn'cr''lf'] Where: nnn = 0 to 4000 (in 1 mA steps) Notes: 1. The 'x' (< or >) parameter is only returned if the level has exceeded the computational resolution of the system. 2. 'No Data' is returned if the level cannot be calculated. 3. Sampling' is returned if not enough data is currently available to calculate the level. Current Sweep Value Command: Response: <add/CSV_'cr' >add/CSV_xsnnnnn’cr’ CD_yyy'cr''lf] Where: x = < or > (data modifier to indicate that the sweep offset value is less than or greater than the returned value). s = + or - (sweep offset from center). nnnnn = 0 to 75000. yyy = OK or FLT (decoder lock status OK or FAULT). Notes: 1. The 'x' (< or >) parameter is only returned if the level has exceeded the computational resolution of the system. 2. 'No Data' is returned if the level cannot be calculated. 3. Sampling' is returned if not enough data is currently available to calculate the level. Notes: 1. The 'x' (< or >) parameter is only returned if the level has exceeded the computational resolution of the system. 2. 'No Data' is returned if the level cannot be calculated. 3. 'Sampling' is returned if not enough data is currently available to calculate the level. A–27
Related documents
SLM-7650 - MetFY3x Processor software
SDM-300L SATELLITE MODEM
Comtech EF Data SDM-309B Specifications
intext:Bedienungsanleitung filetype:pdf
Cisco 3200 Series Specifications
Modicon TSX Compact and TIO for Rail(way
Paradise RA 5785 User's Manual
Comtech EF Data SDM-650B Specifications
Comtech EF Data SDM-100A Specifications
Evolution Series Handbook
BVQ user`s guide-v15-20131129_0622