Download RAD Data comm Optimux-106 Specifications
Transcript
Chapter 4 Configuration Installation and Operation Manual Configuring Redundancy Configuring Local Redundancy Optimux-106 Configuration>System>Redundancy>Local Redundancy 1. Force Link 2. Mode > (LINK A) (Auto) > Please select item <1 to 2> ESC-Previous menu; !-Main Menu; &-Exit Figure 4-16. Local Redundancy Menu Table 4-11. Local Redundancy Parameters Parameter Possible Values Description Force Link Link A Sets the active link. Link B Mode Note Auto When the selected Main Link (for example, Link A) fails, Optimux-106 automatically switches over to the backup Main Link (Link B, in this example). When Link A recovers, the active link returns to Link A. Manual When the selected Force Link fails, the system switches to the backup link. The backup link remains in use, even if the Force Link returns to service. Off Turns off redundancy. When the selected Main Link fails, Optimux-106 does not change over to the backup Main Link. You can set the mode for the remote device, which will then perform redundancy according to the status of its links. Configuring Remote Redundancy Optimux-106 Configuration>System>Redundancy>Remote Redundancy 1. Force Link 2. Mode > > (LINK A) (Auto) > Please select item <1 to 2> ESC-Previous menu; !-Main Menu; &-Exit Figure 4-17. Remote Redundancy Menu The parameters for configuring remote redundancy are the same as those for configuring local redundancy. For more information, see Table 4-11. 4-12 Configuring Optimux-106 for Operation Optimux-106 Ver. 6.1