Download Cisco MGX-FRSM-2CT3 Specifications
Transcript
Chapter 9 Switch Operating Procedures Managing Redundant APS Lines Table 9-6 Options for cnfapsln Command (continued) Option Description -dr The direction option, which specifies the communication paths to be switched when a failure occurs. The options are unidirectional or bidirectional. When the unidirectional option is selected, only the affected path, either transmit or receive, is switched. When the bidirectional option is selected, both paths are switched. To set this option, replace the <direction> variable with 1 for unidirectional operation or 2 for bidirectional operation. -rv The revertive option, which defines how the switch should operate when a failed line recovers. The options are revertive and nonrevertive. When the -rv option is configured for revertive operation and the working line recovers, the switch will switch back to the working line after the period specified by the -wtr option. If the line is configured for nonrevertive operation, a failure on the working line will cause the switch to use the protect line until a manual switchover is initiated as described in “Switching APS Lines.” To set this option, replace the <revertive> variable with 1 for non-revertive operation or 2 for revertive operation. -proto The protocol option, which determines whether the switch will use the standard Bellcore protocol, or the ITU protocol. Switching APS Lines To switch between two APS lines, enter the switchapsln command as described in the following procedure. Step 1 Establish a configuration session using a user name with GROUP1_GP privileges or higher. Step 2 Enter the switchapsln command as follows: mgx8830a.1.PXM.a > switchapsln <bay> <line> <switchOption> <serviceSwitch> Select the working line to switch by replacing <bay> with the bay number of the working line, and replacing <line> with the line number for the working line. Table 9-7 describes the other options you can use with this command. Table 9-7 Options for switchapsln Command Option Value Description switchOption 1 Clear 2 Lockout of protection 3 Forced working->protection 4 Forced protection->working 5 Manual working->protection 6 Manual protection->working; applies only to 1+1 mode 0 or 1 0 switches specified line. 1 switches all lines. serviceSwitch Cisco MGX 8800/8900 Series Software Configuration Guide Release 5.1, Part Number OL-6482-01, Rev. A0, January 25, 2005 9-25
Related documents
Cisco MGX 8950 Specifications
Cisco MGX 8950 Specifications
Cisco Systems MGX 8850 Reference Guide
Cisco RPM-XF Specifications
Cisco Systems MGX and SES User's Manual
Honeywell R8182F User's Manual
Cisco Systems 78-12510-02 Router User Manual
Cisco Systems RPM-XF User's Manual
Cisco Multimode LC Cable
69-0131s - ermostato economizador de combustible t8602