Download Cisco MGX-FRSM-2CT3 Specifications
Transcript
Chapter 9 Switch Operating Procedures Managing NCDP Clock Sources Table 9-18 dspncdpclksrcs Command Objects (continued) Parameter Description Prs id Primary source ID (prs-id) is either 0 for external or 255 for internal.The internal primary source is the free-running oscillator on the PXM back card. (Even though the syntax line and the CLI help indicates a range, the only choice in the current release is 0 or 255.) Default: 255 Health Describes the current health of each clock source in the network. The possible health states ar described as follows. • Good—Specified clock source is the current root clock or the second best clock source, and is in good condition. • Bad—Specified clock source was the root clock at some point, but went bad and is no longer available. • Wideband-Locking—Specified clock source is being qualified by the clock manager and is in wideband-locking mode. • Narrowband-Locking—Specified clock source is being qualified by the clock manager and is in narrowband-locking mode. • Unknown—Specified clock source is not the root clock source. Display All NCDP Ports on the Switch Enter the dspncdpports command to display general details about all signaling ports for NCDP. U1.8.PXM.a > dspncdpports PortId 6:1.1:1 6:1.1:2 6:1.1:3 Clock mode disable disable disable Clock Vpi 0 0 0 Clock Vci 34 34 34 Admin Cost 10 10 10 Ncdp Vc down down down Table 9-19 describes the objects displayed by the dspncdpports command. Table 9-19 dspncdpports Command Objects Parameter Description PortId Port identifier in the format slot:bay.line:ifnum. Table 9-1 describes these parameters. Clock mode Displays whether NCDP is enabled or disabled on each port. Clock VPI Displays the VPI of the signaling channel for each port. Clock VCI Displays the VCI of the signaling channel for each port. Admin Cost Displays the routing cost of the port. NCDP VC Displays whether the Ncdp VC is up or down. Display An NCDP Port Enter the dspncdpport <portid> command to display detailed information for a specified NCDP signaling port. Replace <portid> with the port identifier in the format slot:bay.line:ifnum. Cisco MGX 8800/8900 Series Software Configuration Guide 9-38 Release 5.1, Part Number OL-6482-01, Rev. A0, January 25, 2005
Related documents
Cisco MGX 8950 Specifications
Cisco MGX 8950 Specifications
Cisco Systems MGX 8850 Reference Guide
Cisco RPM-XF Specifications
Cisco Systems MGX and SES User's Manual
Honeywell R8182F User's Manual
Cisco Systems 78-12510-02 Router User Manual
Cisco Systems RPM-XF User's Manual
Cisco Multimode LC Cable
69-0131s - ermostato economizador de combustible t8602