Download The DatasheetArchive - Datasheet Search Engine

Transcript
Calculating SLIC Transfer Functions
Run # 1
B-FILTER calculation results
Reference impedance for optimization:
ZLRP1 = .000
ZLCP1 = .000
ZLRP2 = .000
ZLRS = 600.
ZLCS = .000
ZLCP2 = .000
Calculated and quantized coefficients:
XB
=
–.14825
–.09832
XBQ =
–.14453
–.09766
2nd part of bytes
1st part of bytes
–.71061
–.25357
.15054
.05259
.01320
.07862 –.07985
.03775
–.71875
–.25342
.15234
.05273
.01318
.07861 –.08008
.03711
B-Filter (0B):
00,35,C1,32,24,65,2B,AB
B-Filter (03):
4B,2B,23,AB,B6,19,BB,23
TRANS HYBRID LOSS
FREQ
(Hz)
100.
200.
300.
400.
500.
600.
700.
800.
900.
1000.
1100.
1200.
1300.
1400.
1500.
1600.
1700.
1800.
1900.
loss
(dB)
34.515
28.677
34.913
43.719
52.062
42.911
39.398
37.744
36.977
36.864
37.292
38.247
39.698
41.846
44.876
48.419
48.770
45.555
42.603
FREQ
(Hz)
2000.
2100.
2200.
2300.
2400.
2500.
2600.
2700.
2800.
2900.
3000.
3100.
3200.
3300.
3400.
3500.
3600.
3700.
3800.
loss
(dB)
40.546
39.164
38.275
37.712
37.445
37.399
37.484
37.598
37.641
37.537
37.359
37.168
36.982
36.732
36.160
34.939
33.277
31.896
32.162
Additional B-filter delay (in seconds): .625E–04
Bytes for B-filter delay (18):
19,19,11,19
Semiconductor Group
319