Transcript
System Messages Number 20011 Effect/Cause Remedy An error has occurred in a script called in by the script specified. Execution of the script function has, therefore, been terminated in the subscript. Select the scripts from the configuration which were directly or indirectly called in via the specified script. In this case, it is advisable to check any previous system messages too. Check Tags, whether the types used are permissible. Check Functions, whether the number and types of parameter are correct. 20012 Inconsistent configuration data is present. Therefore, the script could not be created. Compile the configuration again. 20013 VBScript.dll is not correctly installed. Therefore, no scripts Re-install ProTool/Pro RT. can be executed. 20014 A value is returned by the script function which is not written in any configured return tag. Select the specified script in the configuration. Check whether the script name has been assigned a value. 20015 Too many scripts have been triggered in quick succession. If more than 20 scripts are queued to be processed, any subsequent scripts are rejected. In this case, the script indicated in the message is not executed. Check where the scripts are being triggered from. Extend the times, e.g. the polling time of the tags, which trigger the scripts. 30010 The tag could not accept the function result, e.g. in the case of exceeding the value range. Check the tag type of the function parameter. 30011 A function could not be executed because the function was assigned an invalid value or type in the parameter. Check the parameter value and tag type of the invalid parameter. If a tag is used as a parameter, check its value. 40010 The function could not be executed since the parameters could not be converted to a common tag type. Check the parameter types in the configuration. 40011 The function could not be executed since the parameters could not be converted to a common tag type. Check the parameter types in the configuration. 50000 The operating unit receives data faster than it is capable of – processing. Therfore, no further data is received until the data currently available has been processed. Data exchange then resumes. 50001 Data exchange has been resumed. 60000 This message is generated by the function “Display system – messages”. The text to be displayed is transferred to the function as a parameter. 60010 The file could not be copied in the direction defined because Restart the function or check the paths either one of the two files is currently open or the source/tar- of the source/target files. get path is not available. Using Windows NT with NTFS: The It is possible that the Windows NT user has no access rights user executing ProTool/Pro RT must be granted access rights for the files. to one of the two files. Communication for Windows-based Systems User’s Manual Release 01/99 – A-3