Download Communication for Windows

Transcript
System Messages
Number
20011
Effect/Cause
Remedy
An error has occurred in a script called in by the script
specified. Execution of the script function has, therefore,
been terminated in the subscript.
Select the scripts from the configuration which were directly or indirectly
called in via the specified script.
In this case, it is advisable to check any previous system
messages too.
Check Tags, whether the types used are
permissible.
Check Functions, whether the number
and types of parameter are correct.
20012
Inconsistent configuration data is present. Therefore, the
script could not be created.
Compile the configuration again.
20013
VBScript.dll is not correctly installed. Therefore, no scripts Re-install ProTool/Pro RT.
can be executed.
20014
A value is returned by the script function which is not
written in any configured return tag.
Select the specified script in the configuration.
Check whether the script name has
been assigned a value.
20015
Too many scripts have been triggered in quick succession.
If more than 20 scripts are queued to be processed, any
subsequent scripts are rejected.
In this case, the script indicated in the message is not
executed.
Check where the scripts are being triggered from.
Extend the times, e.g. the polling time
of the tags, which trigger the scripts.
30010
The tag could not accept the function result, e.g. in the
case of exceeding the value range.
Check the tag type of the function parameter.
30011
A function could not be executed because the function was
assigned an invalid value or type in the parameter.
Check the parameter value and tag type
of the invalid parameter.
If a tag is used as a parameter, check its
value.
40010
The function could not be executed since the parameters
could not be converted to a common tag type.
Check the parameter types in the configuration.
40011
The function could not be executed since the parameters
could not be converted to a common tag type.
Check the parameter types in the configuration.
50000
The operating unit receives data faster than it is capable of –
processing. Therfore, no further data is received until the
data currently available has been processed. Data exchange
then resumes.
50001
Data exchange has been resumed.
60000
This message is generated by the function “Display system –
messages”. The text to be displayed is transferred to the
function as a parameter.
60010
The file could not be copied in the direction defined because Restart the function or check the paths
either one of the two files is currently open or the source/tar- of the source/target files.
get path is not available.
Using Windows NT with NTFS: The
It is possible that the Windows NT user has no access rights user executing ProTool/Pro RT must
be granted access rights for the files.
to one of the two files.
Communication for Windows-based Systems User’s Manual
Release 01/99
–
A-3