Download High Performance Model QCPU(Q Mode)User`s Manual(Function
Transcript
14 SYSTEM CONFIGURATION OF MULTIPLE PLC SYSTEMS MELSEC-Q 14.2 Precautions During Multiple PLC System Configuration 14.2.1 Function versions of High Performance model QCPU, motion CPUs and PC CPU module that can be sued, and their mounting positions (1) Function versions (a) Allowable function versions and confirmation method 1) To configure a multiple PLC system, use the High Performance model QCPU and Motion CPU of function version B. 2) To use the PC CPU module, use the following High Performance model QCPU and Motion CPU. • High Performance model QCPU: "03051" or later first five digits of the serial number of function version B • Motion CPU: The first digits of the serial number must be as follows. Q172CPU ....... "H" or later Q173CPU ....... "G" or later 3) The function version of the High Performance model QCPU and Motion CPU can be checked at the following places. • Ratings nameplate of High Performance model QCPU and Motion CPU • Product data list of system monitor of GX Developer (Refer to Section 2.3 for details.) (b) Operations with different function versions Function version A High Performance model QCPUs cannot be used on a multiple PLC system. Errors like the ones shown in table 14.1 will be triggered and the multiple PLC system will not start up if function version A High Performance model QCPUs are used on a multiple PLC system. If any of the errors shown in table 14.1 are displayed with the GX Developer Version 6 or later PLC diagnosis function, replace the function version A High Performance model QCPU with a function version B High Performance model QCPU. Table 14.1 List of operations with differing function versions PLC No.1 PLC Nos. 2 to 4 Function version A Function version A Function version A Function version B Function version B Function version A Function version B Function version B Status of PLC No.1 Status of PLC Nos. 2 to 4 UNIT VERIFY ERROR SP. UNIT LAY ERROR (Error code: 2000) (Error code: 2125) UNIT VERIFY ERROR (Error code: 2000) MULTI EXE. ERROR MULTI EXE. ERROR (Error code: 7010) SP. UNIT LAY ERROR (Error code: 7010) (Error code: 2125) No error No error : The following errors may occur besides "MULTI EXE. ERROR" when the PLC is turned on or the High Performance model QCPU for PLC No.1 is reset. • CONTROL-BUS ERR. (error code: 1413, 1414) • MULTIPLE PLC DOWN (error code: 7000, 7002) 14 - 4 14 - 4
Related documents
User`s Manual (Hardware Design, Maintenance and
User Guide - William Green
USER MANUAL
Process CPU User`s Manual(Function Explanation
Model Q2AS(H)CPU(S1)User`s Manual
High Performance Model QCPU(Q Mode)User`s Manual(Function
Manual - 首頁- B&K Precision
Mitsubishi Programmable Controller Training
QSCPU CPU Module User`s Manual (Hardware)
"user manual"
MELSEC-L CPU Module User`s Manual (Function Explanation
3 - Busy Bee Tools