Download User and reference manual
Transcript
Alarm attributes Crocus CNV 9.5 Interface alarms Refer to Section 9.2 - Introduction to the alarm attributes for the general alarm attributes. crocusIfConv<2m/Nx64><Tt/Cv>/<dteInterface>/alarmInfo The different alarms related to the <dteInterface> object together with their explanation and their default alarmMask and alarmLevel value are given in the following table: The alarm … linkDown (for RS530, V35, V36I) linkDown (for X21) linkDown (for Bridge) linkDown (for Router) 124 is generated … Default value alarmMask alarmLevel enabled 3 when no valid C signal is detected. I.e. the connection between the Crocus CNV and the DTE is down. enabled 3 when there is no connection with the LAN. I.e. the LAN is not connected or no valid LAN signals are present. enabled 3 when there is no connection between the router and the Crocus CNV. Because this connection is made by the interface connector, it is highly unlikely that this alarm will be generated. However, when it does occur it might indicate that the router interface is faulty. enabled 3 when no RTS signal is detected. I.e. the connection between the Crocus CNV and the DTE is down. The linkDown alarm is only generated if the attribute rtsControl is set to external. If the attribute rtsControl is set to internal, the linkDown alarm will never be generated. Reference manual