Download AFE Controller User`s Manual

Transcript
Functional Description
2.4.2 Calibrate
The Calibrate state is used to calibrate system hardware as applicable. Power hardware is not
operable while in the Calibrate state. Following successful calibration, the state machine will
auto-transition to the Precharge state.
2.4.3 Precharge
The Precharge state is used to wait for a valid AC line interface before attempting to begin the
DC link charging process. As long as the operating mode is not stand alone voltage mode, the
state machine will remain in the Precharge state indefinitely, transitioning either on a fault or
upon detecting a valid AC line. Power hardware is not operable while in the Precharge state. If
stand alone voltage mode is selected, the state machine will transition directly to the Idle state.
2.4.4 Charge
The Charge state is used to charge the DC link capacitance in a controlled manner before
directly connecting to the AC line. Once the DC link is charged, the state machine will sequence
to the Idle state. Power hardware is not operable while in the Charge state.
2.4.5 Idle
Once in the Idle state the AFE is ready for use. The state machine will remain in the Idle state
indefinitely, transitioning either on a fault, a turn-on command, or upon detecting an invalid AC
line. If the operating mode is switched from stand alone to either DC Link voltage regulation
mode or current regulation mode the state machine will transition back to the Precharge state.
2.4.6 On
While in the On state the AFE is processing power and controlling either the AC line current or
the DC link voltage, depending on the configuration. The state machine will remain in the On
state indefinitely, transitioning either on a fault or a turn-off command. When a turn-off
command is received, the state machine will immediately go to the Idle state if in voltage
regulation mode or to the Turn Off state if in current regulation mode.
2.4.7 Turn Off
The Turn Off state is only used when the AFE is operating in current regulation mode and was
commanded to turn off. This state is used to wait for the current to ramp down to zero based
on the user-specified rate set in the Turn Off Current Slew Rate configuration register (PID
0x8093). Once the current reaches zero the state machine will then transition to the Idle state.
2.4.8 Low DC Link
If the controller is in the Idle state and configured for stand alone operation, the state machine
will transition to this Low DC Link state if the measured DC link voltage falls below the value
Publication UM-0021
11