Download User Manual

Transcript
OPTIMOD 6300 DIGITAL
OPERATION
Please note that it is impossible to design such a system to handle all program material without audible side effects. You will get best results if you set the MB DOWN
EXPANDER control of the noise reduction system to complement the program material you are processing. The MB DOWN EXPANDER should be set higher when the input
is noisy and lower when the input is relatively quiet. The best way to adjust the MB
DOWN EXPANDER control is to start with the control set very high. Reduce the control
setting while watching the gain reduction meters. Eventually, you will see the gain
increase in sync with the program. Go further until you begin to hear noise modulation—a puffing or breathing sound (the input noise) in sync with the input program
material. Set the MB DOWN EXPANDER control higher until you can no longer hear the
noise modulation. This is the best setting.
Obviously, the correct setting will be different for a sporting event than for classical
music. It may be wise to define several presets with different settings of the MB
DOWN EXPANDER control and to recall the preset that complements the program material of the moment.
Note also that it is virtually impossible to achieve undetectable dynamic noise reduction of program material that is extremely noisy to begin with, because the program
never masks the noise. It is probably wiser to defeat the dynamic noise reduction
with this sort of material (traffic reports from helicopters and the like) to avoid objectionable side effects. You must let your ears guide you.
Band 5 is particularly critical for noise reduction because much of the Downward Expander’s utility lies in hiss reduction. Hiss has most of its energy in band 5, while
program material typically has less energy in this band, so the B5 DOWN EXPANDER
DELTA THRESHOLD control’s setting is critical to removing hiss while minimizing removal of desired program energy.
Starting in V1.1, the Downward Expander’s dynamic frequency response is no longer
constrained to being strictly lowpass—Band 5 is now uncoupled from the lower
bands, so the band 5 downward expander can produce less gain reduction than
other bands. This can help prevent loss of desired high frequency material in the
program.
B3>B4 CPL (“Band 3>4 Coupling”) control determines the extent to which the gains
of bands 4 (centered at 3.7 kHz) and 5 (above 6.2 kHz) are determined by and follows the gain of band 3 (centered at 1 kHz). Set towards 100% (fully coupled) this
control reduces the amount of dynamic upper midrange boost, preventing unnatural upper midrange boost. The gain of band 5 is further affected by the B4>B5 CPL
control.
The COUPLING controls use an “OR” algorithm: the final gain reduction in a given
band is the higher of (1) the gain reduction that would have been produced in that
band with no coupling, OR (2) the gain reduction in the adjacent coupled band multiplied by the setting of the COUPLING control.
For example, assume that Band 4 would produce 10 dB of gain reduction with no
B3>B4 coupling. If the B3>B4 CPL control is set to 50%, Band 3 will not affect Band
4’s gain reduction unless Band 4 is producing more than 20 dB of gain reduction. At
3-53