Download Artisan Technology Group is your source for quality new and
Transcript
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment • FAST SHIPPING AND DELIVERY • TENS OF THOUSANDS OF IN-STOCK ITEMS • EQUIPMENT DEMOS • HUNDREDS OF MANUFACTURERS SUPPORTED • LEASING/MONTHLY RENTALS • ITAR CERTIFIED SECURE ASSET SOLUTIONS SERVICE CENTER REPAIRS Experienced engineers and technicians on staff at our full-service, in-house repair center WE BUY USED EQUIPMENT Sell your excess, underutilized, and idle used equipment We also offer credit for buy-backs and trade-ins www.artisantg.com/WeBuyEquipment InstraView REMOTE INSPECTION LOOKING FOR MORE INFORMATION? Visit us on the web at www.artisantg.com for more information on price quotations, drivers, technical specifications, manuals, and documentation SM Remotely inspect equipment before purchasing with our interactive website at www.instraview.com Contact us: (888) 88-SOURCE | [email protected] | www.artisantg.com User Manual TDS 340, TDS 360 & TDS 380 Digital Real-Time Oscilloscopes 070-9459-01 1lllllI nlllllllllllllll Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com - . < . . -m.-.. .--..e . TEK .INTER-OFFICE COMlvllJNlCATlON .. TO FWW M3KC.T Sohn 94-540 Martin 3:.' t Juno 25, 1991 Frank Gray, SO-PAT GIDEP permit request In response to the request to grant permission to the Industry Exchange Pro ram (GPDEP) to reproduce Tektronix operator, service and P nstruction manuals, Tektronix, Inc. hereby grant6 such permission for distribution of such documents to any GTDEP user that is a full participant in the Metrology Data Interchange Data Base of GIDEP provided that all copies of the original work include the entire copyright notice and ownership statement exactly a-& it appears in the original, together with the Legend "Reproduded with Government pemieeion,a This permission has been approved by the Intellectual Committee of Tektronix and a copy of this memo aeon% 1[ded to GIDEP to provide'the requested permission. g:&dy Group Pat&t Coun&al Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com may Table of Contents General Safety Summary .................................... Preface ................................................... vii xi slatup ........................................................ l-2 l-.3 l,-5 I-7 Getting Started Line FuseReplacemcnl............................................ SeNTcst ........................................................ FunctionalTcs1................................................... Operating Basics DisplayandPowerControls......................................... VerricalControls.................................................. HorizontalControls ............................................... TriggerControls.. ................................................ MiscellaneousControls ............................................ DisplayMap ..................................................... Inputs .......................................................... Rear-Panel Connectors.................. .......................... UsingtheMenuSystem............................................ Usinglhc Probes ................................................. UsingAutoset.................................................... lntrnduction ............... . ............................... Manipulating Waveforms ................... . ................ VerticalOperations................................................ HorizontaIOperations............................................. DisplayingMath Wavcfums ........................................ Tr&ring ...................... ._......_.................f EdgeTriggering .................................................. VidcoTriggering ................................................. TaklngMeasurements ...... ......f.....f .................... AutomatedMeasurements.......................................... Tating Measurements with Cursors................................... Controlling Acquisition .......... . .. +. .... _f ..... . ........... . ................. Controlling the Display .................... .._........ .......... UsingthePFT ........................ Description...................................................... Operation....................................................... Considerations for UsingI+Ts ...................................... Making Hard Copies (Option 14 Equipped Instruments Only) .. . . . ConfiguringHardCopyOutput ...................................... SavingaHardCopytoDisk(~S360andTDS380only) ................ TDS 340, TDS 360 & TDS 380 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com 2-l z2 2-3 24 2-5 26 2-7 2,-8 2-9 2-12 2-15 >l 3-3 3-3 36 3-s 3-11 3-11 3-14 3-17 3-17 3-21 3-25 3-27 3-31 3-31 3-32 3-36 3-41 3-41 343 I ‘T;lbleof Comcnts Saving and Recalling Waveforms 3-45 .............................................. UsingRefmenceWav&rms ............................................... 3-45 UsingtheDisk (TDS 360andTDS 380only) 347 : :: Viewinga Wdom ona Spreadsheet 349 ............................. Savin:: and Recalling Front-Panel Setups 3-51 ................................ 3-52 UsingInlemalMemory ............ ...................... UsingtheDisk(~S360and??)S380only). .......................... 3-52 Using the File System (TDS 360 and ‘CDS380 only) .............. 3-53 Ilsing the Utility Menu SettingtheDateandTime ................................................................................ Appendices Appendix A: Specifications ................................... WuramedClwxtcristics........................................................... TypicalCharacteristics ............................ NominalTraits ................................................... Appendix B: Performance Verification Conventions.. .. ........ ............................................................... TeslEquipment................. .................................. TcstRccord,.,,.,,,,,,- A-l A-l A-5 A-7 R-l B-1 B-3 B-4 PcrfOrmnceTestOvcrvicw................................................................................... n-5 SignalAcquisitionSystcrnChecks ............... ... . ................ B-5 Time BaseSystemCheeks.......... ................................ B-IO ‘%ig:er SystemChecks ..... ..................................................................... B-11 B-14 SineWaveGeneratorLcvclingProcedure Appendix C: Options and Accessories _......................... C-l Options............... C-l StandardAccessories c-3 C-3 OptionalAccessories...................................................................................................................................... AccessoryProbes................ C-4 ................................. AccessoryCables.............. ................................... Cd Appendix D: General Care and Cleaning ....................... I)-1 Gencrdcm .. ........ ..... ..................................... D--l Clcanin~~ * ........................................................ D-l Glossary index ii TDS 340, TDS 360 & TDS 380 User Manuti Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Table of Contents The ON/STBY button .............................. Line fuse removal ................................ Verifying adjustments and signal path compensation ... .,..... Hookup for functional test ................... Figure Figure Figure Figure l-l: l-2: l-3: l-4: Figure Figure Figure Figure Figure Figure Figure Figure ,,..... 2-l: Using menus ............................... .,..... 2-2: A pop-up menu ............................ ,,..... 2-3: Connecting a probe ......................... .,..... 2-4: Probe compensation setup ................... .,..... 25: Compensation waveform .................... 2-6: How probe compensation atrects signals ....... ,,..... 2-7: Location of probe compensation ad.iustment ........... ,,..... 2-8: The AUTOSET button ...................... Figure 3-l: Figure 3-2: Figure 3-3: Figure 34: Figure 3-5: Figure 34: Figure 3-7: Figure 3-8: The VERTICAI, MENU button .................... The vertical menu ................................. ...... Inverting a waveform ....................... The HORIZONTAL MENU button ................. ...... The horizontal menu ........................ The MATH button ............................... A math waveform ................................ The TRIGGER MENU button ..................... Figure 3-Y: The edge trigger menu ............................ Figure 3-10: The video trigger menu .......................... Figure 3-11: The video scan-rate menu ......................... Figure 3-12: The MEASURE button .......................... Figure 3-13: The measure menu and active measurements ........ Figure 3-14: The CURSOR button ............................ Figure 3-15: The cursor menu ................................ Figure 3-16: Paired cursor measurements of a sine wave .......... Figure 3-17: The ACQUIRE button ........................... Figure 3-18: The acquire menu ............................... Figure 3-19: The DISPLAY button ............................ Figure 3-20: The display menu ............................... Figure 3-21: System responseto an impulse .................... Figure 3-22: Define FFT waveform menu ...................... 1s 360 & TDS 380 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com l-3 1-t I-6 l-7 210 2-11 212 2-13 t-13 214 2-14 2-15 >3 3-4 >5 s6 3-6 3-8 >9 3-H 3-I,2 3-14 3-15 3-17 3-18 3-22 3-22 3-23 3-25 3-25 3-27 ~27 3-32 3-33 “,. 111 Table of Conrcnts Figure 3-23: Cursor measurement of an FFT waveform .......... Figure 3-24: FFT time domain record vs. FFT frequency domainrecord .......................................... Figure 3-25: How aliased frequendes appear in an FFT .......... Figure 3-26: Windowing the FFT time domain record ............ Figure 3-27: The HARDCOPY button ......................... Figure 3-2X: The UTILITY button ............................ ............................ Figure3-29:ThcsystemUOmenu Figure 3-30~ The reference waveform buttons ................... Figure 3-31: A reference waveform menu ...................... Figure 3-32: Save Format menu .............................. Figure 3-33: The SAVFXXECALL button ....................... Figure 3-34: The save/recall menu ............................ Figure 3-35: File utilities .................................... Figure 3-36: File system - Labelling menu ..................... Figure 3-37: The UTILITY button ............................ Figure 3-38: The utility pop-up menn .......................... Figure 3-3Y: Date and time display ............................ Figure h-l: TDS 340, TDS 360, and TDS 380 dimensions . . . . . . . . . Figure B-l: Menu locations ................................. Figure D-2: Hookup for DC voltage measurement accuracy check ................................................. Figure H-3: Hookup for analog bandwidth check ............... Figure B-4: Measuring analog bandwidth ..................... Figure B-5: Hookup for sampIe rate check .................... Figure Bd: Hookup for trigger sensitivity check ............... Figure B-7: Measuring triger sensitivity ..................... Figure B-8: Hookup for sine wave generator leveling ............ iv 3-35 3-36 3-38 3-39 341 342 342 3-15 345 3-48 3-H 3-51 3-53 3-57 3-59 3-60 361 A-11 o-2 134 B-8 B-9 U-10 B-12 H-13 B-15 -IDS 340, TDS 360 Br TDS 380 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com -‘Isblc of Contents Table 2-l: Autoset defaults ............................ .,..... 2-15 Table 3-l: Measurement definitions ........................... 3-19 Table A-l: Warranted characteristics-signal acquisition system . Table A-2: Warranted characteristics - time basesystem ........ Table A-3: Warranted characteristics - triggering system ....... Table A-i: Power Requirements .............................. .......... Table A-5: Warranted charaderistics - environmental Table A-6: Typical charactelistics - signal acquisition system .... Table A-7: Typical characteristics-triggering system .......... Table A-8: Typical characteristics -probe compensator output ... Table A-Y: Typical characteristics -data handling ............. Table A-10: Nominal traits -signal acquisition system .......... Table A-XX: Nominal traits - time base system ................. Table A-12: Nominal traits-triggering system ................ Table A-13: Nominal traits-display system ................... Table A-14: Nominal traits-I/O interface option .............. Table A-15: Nnminal traits-power distribution system ......... Table A-16: Nominal traits - mcrhanicd characteristics ........ Table A-17: Certifications and compliances .................... A-l A-2 A-3 Table R-1,: Test equipment Table%2:DCaccuracy Table C-l: Table C-Z: Table C-3: Table Cd Table C-5: Table C-6: .................................. ..................................... output connector pins ........................ International power cords ......................... Language options ................................ Standard accessories .............................. Optional accessories .............................. Accessory cables ................................. VGA 380User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com A-3 A-4 A-5 A6 A-6 A-7 A-7 A-8 A-S A-Y A-9 A-9 A-10 A-12 K-3 B-7 C-l C-‘1 C-Z c-3 c-3 C-l Y Tektronix ‘IDS 340, TDS 360, and ‘IDS 380 oscilloscopesarc digital signal processorsandare superbtools for displaying andmeasuringwaveforms.Their performanceaddressesthe needsof both benchtoplab andportable applications with the following features: Two input Chdnneb, eachwith a recordlength of 1,000samplesand X-bit vertical resolution. Both channelSacquirewaveforms simultaneously. 2 Gigasample/sccondmaximum samplerate (TDS 380); 1 Gigasamples/ secondmaximum samplerate (TDS 360); 500 McgasamplesIsecond max,imum samplerate (TDS 340). 400 MHz analogbandwidth and fastesttime basesetting of 2.5 nsidiv (‘IDS 380): 200 MHz analogbandwidth and fastesttime basesetting of 2.5 ns/div (‘IDS 360); 100MHz analogbandwidth andfastesttime base setting of5 ns/div (TDS 340). A full complementof advancedfunctions including on-screenreadout, AUTOSET, cursors,continuously updatedautomaticmeasurements,and FFT. Waveform averaging,waveform enveloping,and hardwarepeak.detection. Floppy disk drive (TDS 380 andTDS 360) for massstorageof waveforms, setups,andhard copies. A unique graphicaluser interface (GUI) and a logical front-panellayout which combine to deliver the standardin usability pioneeredby the TDS family of oscilloscopes. TDS 340, TIX 360 & TDS 380 User Mdnual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Getting Started ,,,--- - Start Up To properlyinstallandpoweron theoscilloscope, performthisprocedure. 1. Checkthatyouhavetheproperelcctticalconnections. Therearlabellists powerrequirements for all possiblevoltage’inputs. 2. Checkthefuseto bcsureit is thepropertypeandrating(Figurel-2). TDS300Seriesoscillo~copcs areshippedwith a UL-approved fuseinstalled. Fusespecifications areasfollows: Smm x 20 mm,time-lag,3.15A, 250V.or 1.25in x 0.25in, cimc-lag,3 A, 250V 3. Connecttheproperpowercordfromtherear-panel powerconnector (Figurel-2) to thepowersystem.Usethepowercordclampto securethe cordto therearpanel. 4. Leavespacefor conlmg.Do thisby verifyingthatUKair-intaksandexhaust holesonthesidesandbottomof thecabinet(wheretttc fanoperates) arefree of anyairflowobstructions. hWe at least5.1,cm (2,in) fret oneachside. 5. PresstheON/STBYbuttonto powerup theoscilloscope (seeFigure1-l). Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com ! 0n 0 0 c0 Q f OWSTBYbutton , Figure I-1:The ONISTBY button Line Fuse Replacement A! WARNING. To avoid injury or death, unplug ths line cord from the .linc voltagt power smrce b&w continuing I. Have handy a flat-bladedscrewdriver 2. Set the oscilloscopeso its bottom is down on the work SUrface facing you. and its rearis 3. Find the lint cord on the rcx cover. (SeeFigure l-2.) Unplug the line cord from its reccptaclc. 4. Find the fusedrawer beneaththe line-voltageplug on the rear :pancl.Now, pry open the drawer with a small flat-bladed screwdriver,andrremovethe line fuse. (SeeFigure l-2.) m35 340, TDS 360 & TDS 380 ‘User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com 1-4 TDs 340. ms 360 & ‘IDS 380 user ,Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Getting Started -- This procedureusesinternlll routinesto verify that the oscilloscopefunctions and passesits internal self testsand signal-pathcompensations.It also confirms that the oscilloscope wasadjusted properly at the dme it was last adjusted.No test equipmentor hookupsarerequired. EquipmentRequired:None. TimeRequired:Approximately 5 minutes. Prerequisites:Power up the oscilloscopeand allow a 20 minute warm up before doing this procedure. Procedure: 1. Pressthe front-panelbutton UTILITY. 2. Pressthe main-menubutton System to selectDiag. 3. Pressthe main-menu button Execute and thenpressthe side-menubutton OK Confirm Run Test. The internal diagnosticsverify properoscilloscope function. This vcrlfication takesabout30 seconds.While it progresses,a variety of test patternsflash on screen.When finished, statusmessages appearon the screen. 4. Check that the screenreportsno failures. If it reportsa failure, the oscilloscopehas failed the self test. Contactyour Tektronix representadvefor assistance. 5. PressCLEAR bmw. 6. PressUTILITY and thenpressthe main-menubutton SystemI:OselectCal. 7. Check that the word Passappearsin the main menu underthe ‘Voltage Reference,Timing, and Ext Trig menulabels. (Set Figure l-3.) If any of the labels readFall, the oscilloscopehas failed the self test. Contactyour Tektronix rcprcsentativefor assistance. 360& -IDS 380User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Gming Swtcd First, display lheGAL menu. Third. run a signal palh compensalm and verify Slatus is Pass. 1 Figure I-3: Verifyingadjustmentsand signal pathcompensation 8. PressSipnti Pathand thenpresstbc sidemenubuttonOK Compeasate S@II Paths.Whencompensation completes, thestatusmessage updatesto Passor Failin themaanmenu 9. Checkthat thewordPassappears underSignalPathin themainmt:nu.(See Figure l-3.) If Passdoes not appear,theoscilloscope hasfailedthe performance verification;rctumit to Tektronixfor servicing. TDS 340,T’DS360& TDS380UserManual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Getting Started Functional Test ‘kc purposeof this proccdurcis to conlkm that the oscilloscopefunctions properly. NOTE Thisprocedureverifiesfunctions; that is, ii verifies that oscilloscope feutures operate.It doesnot verify that they upcmte within limits. Therefbre, when the instructions thatfollow call for you to veriyythat a signal appears on-screen“thnl is aboutJive divisions in amplitude’” or “has a period of’about six horizontal divisions,” do NOT interpret the quantitiesgiven as limits. Operation within limits is checlledEnthepeflormance tests,which begin on pug’eB-5. 110 NOT make changesto thefront-penel settingsthat are not called out in the procedure.If you make changesto thesesettingsother than thoseculled out in theprocedure,you may obtuin invalid rest&s. In this case,just redothe vrocedurefrom stev 1. Equipment Required: One P6109B (TDS 340),P6111B(TIX 360), or I?61146 (TDS 380) probe. Time Required: Approximately 5 minutes. Procedure: 1. Install tbc probeon CB 1. Connectthe probetip to PROBE COMP on tie front panel; leave the probe groundunconncctcd.(SeeFigure IA.) Figure 1-4: Hookup for functional test TDS 340, TDS 360 & TDS 380 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com -Getting Started 2. Frcsstie front-panelbuttonSAVEmCALL, themain-menu bul:tonRecall FactorySetup,andthentheside-menu buttonOK ConfirmFactoryInit. 3. PressAUTOSET. 4. SettheVOLTS/DIVto 1 V. USClhc verticalPOSITION knobto ccntcrthe waveformverticallyonscreen. 5. SettheSEC/DIVto 250ps. 6. Checkthata squarewaveprobe-com,pen,sation signalof aboutfivedivisions in amplitudeis on screen. 7. Cheekthatoneperiodof thesquarewaveprobe-compensation signalis aboutfourhorizontaldivisionson screen. 8. CheckthatthehorizontalPOSInON knobpositionsthesignalIcft andright on screenwhenrotated. 9. Pressthefront-panelbuttonTRIGGERMENU, themain-menu button Mode,andthentheside-menu buttonNormal. 10.Checkthatthetrigger-level. readoutfor themaintriggersystemchanges with thetriggerLEVELknob. ‘Il. Cheekthatthetrigger-levelknobcantrig&r anduntriggerthesquare-wave signalasyourotateit. (Leavethesignaluntriggcred.) 12.CheckthatpressingSETLEVELTO 50%triggersthesignalthatyoujust left untriggcred. 13. Pressthefront-panelbuttonACQUIRE,themain-menu buttonMode,and rhcntheside-menu buttonSample. 14. CheckthatUKoscilloscope displaysanactivelyacquiringwaveform on-screen. (Notetbdtthereis noisepresenton thepeaksof thesquarewave.) 15.Presstheside-menu buttonPeakDetect.Cheekthattheoscilloscope displays an activelyacquiringwaveformon screenwith the.noise“peakdetcctcd.” 16. ‘Press theside-menu buttonEnvelope.Checkthattheoscilloscope displays anactivelyacquiringwaveformonscreenwith thenoisedisplayed. 17. Presstheside-menubuttonAverage.CheckthattheosciIloscope displaysan activelyacquiringwaveformon screenwith thenoisereduced. 18. PressWAVEFORMOFFto removeChannel1 from thedisplay. 19. PressCB 2 andmovetheprobeto theCH 2 input. 20. Repeatsteps3 through17for Charm&l 2. TDS 340,T!X 360& TDS380UserManual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com - Getting Stxtcd 21. Disconnectthe probe from the channel: input and the PROBE: COMP terminal. 340, TDS 360 & TDS 380 UserManual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Operating Basics This chapterbegins with tight illustrations that identify anddcscr’lbceach control and connectoron the TDS 300 Series oscilloscope.Next, 0perating Basics coverstheseadditional topics: a Using the menu system W Using probes II Using autoset Display and Power Controls I I The SideMenubuttaxi provide accessto side menusalections. See page 2-9 for m0rf.z informationaboutIho user interface. The ONETBYbutiontoggles The MainMenu buttonsprovideacces to Instrumentpower. main menuselections.See page 2-9 for mow informationabout the user intetfacs. TDS 340, TDS 360 & TDS 380 UserManual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com VerticalControls The VanicalPOSlllONknobcontrols lhs veniealpositionof the selected waveform. Tho WaveformSalectbunoosdisplay andselectwaveforms(CHi,GH2,MATH, REFl,andREF2).Alighlne~toabutton illuminateswhenthat waveformis selected. The VER-iiCAtMENUbunoncallsup the verticaloperadonsmenu. Forrnoro informationabati verticaloperations, seepage z-3. The SCALEknobcontrolsthe vefliwl scaleof the solededwaveform. Probecornpens& output.see page 2-12 for instrucrionson howto compensatethe probes. ’ The WAVEFORM OFFbutronturns off the selectedwaveform. TDS 340,TDS360&TDS380UserManual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com The HorizontalPOS~IONknobcon~r& the horizontalpositionof allwaveforms. The HORIZONTAL MENUbuttonM/ISup iho horizontaloperationsmsnu.For more informationabout horizontaloperations, see page SC The SCALEknobrnntrolsthe horizontal scaleof the activewaveforms. -IDS 340,TDS 360&~~S380UscrManual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com 2-3 Miscellaneous Controls The MEASURE button wlk upthe automated measurements menu. See page %I7 for more information about automated measuremeo,s. The UTILITY button 4s up the utiiily menu. See page 3-59 for more information about utilities. The floppy disk drive provides mass wage for waveforms, setups. and hard copies. l-he AUTOSET bullon aulomalically ss$ up rhe instrument to produce a usable display of the input signals. See page 2-15 for more information about Ihe auloset fundion. The General PurQOSe Knob controls many side-menu fundions. including the cursors. The SELECT button switches control from cursor to 0”rscI. bUllOil SlatIS quisfiion. The HARDCOPY button star% print e -41 for more The ACQUIRE button calls up the acquisition menu. See page 3-25 for more information about controlling The SAWRECALL button calls up the save/recall me”“.Seepage345for more information about saving and recalling wavefarms. See page %51 for more information about saving and recalling The CURSOR bunon ~1x11s up the cursor menu. See page >21 for information aboutmakingmeasurementswilhcursois. The DISPLAY button calls up the display menu. See page >27 for information about controlling the display. TDS 340, TDS 360 & TDS 380 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com 2-5 Display Map k Iwaveformomrd. / // Showswhat patsof Ihe waveformrecord16dlsplayed. Thevalueenteredwiththe generalpurposeknob. * Whenthe generalpurpose knobis firstassigned.Ihe knob iconappearshere. The StatusReadoutsshow triggerstatusand acquisiCon ~tat~s(modeandsamplingrare or numberof acquisitions). Cursormeasurement readouts.See pageZ-21 for moreinformationabout C”rsOrs. TriggerlevelindicatorTriggerwin! indicator The sidemew offersa choiceof specific actions. Chanoeiground indicator The Channelreadout showsIhe verticalscaleof all anive channels. The Triggerreadoulshows the triggerSDU~W and level and whetherlheuscilloscope is triggeredon the risingor failingedgeof the waveform. The mainmenu offersa choiceof majoractions. The he base readoti showsthe lime baseseffing.M indicates (M)ainlime base,0 indicates (D)elayedtime base, Whenin video-lriuaer .,_ mode, the readoutdisplayssourca and triggerfeafuru(Field1, Field2, or Lines). TDS 340, TDS 360 & TDS 380 Userh,UNd Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com The channelBNCinputs(CHl and CH2)acceptelectricalsignalsfor display. The EXTTRIGinputacceptsex~emai triggersignals.See page3-12 for more informationabout external triggering lB.7 340, TDS 360 & TDS 380 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Opcming -,--- Basics Rear-Panel Connectors The Option 14 Panel (Option 14 instruments only) allows ~ccoss 10three communi&ons interfaces: a Centronics parallel port, an US-232 interface. and a GPIE interface. It also includes a VGA videwxnparibla output pod and a power mnn~clor for Ihe optional TDS4F5Q printer upgrade kit, The power connector accepts line voltage to powerthe inslrument.SeepageC-1 for a lis! of power cord and connector options. - The fuse drawer holds the line fuse. See page 13 for fuse replacement procedures. YOUcan “so Ihe Centronics, K-232, and GPIB interfaces to Iranemil hardcopy data: see page Wl tar hard copy procedures. You can use lhe WI6 and RS-232 innixes to operateaodprogt~mtheoscilloscopefromaGPl~ controller: see Ih@ TDS 340, lDS 360 & TDS 380 ProgrammerManualfor more informaban. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com the MenuSystem TDS 300 Series0sciHoscopesuse an intuitive userinterface.This intetiacc reducesfront-panelclutter wh,ile allowing easyaccessto specializedfunctions throughthe menu st~hxe. The procedureon page2-10 illustrateshow to navigatein the menu structure. If you areunfamiliar with this menu system,you may want to run through the procedureseveraltimes to learn how you can accessfunctions and subfunctions. Refer to Figure 2-l as necessary. TDS 360 & TDS 380 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com 2-9 Operatin: Basics Tdumnjx 1 Pressany of the fmnt-panel menubutloos ‘IDS360 --we”m - ,-,, 2 Selsctankm fmmthemain(bottom) menu oruseleftmost button topopupselections. 0 0 A# ifdisplayed 3 SelodanitemfromIhesidemenu. 0 0 4 Adjudmenuitamvalues withgeneral purpose knob. Figure2-1: Usingmenus 1. Pushone of the indicated front-panelbuttons to call up a menu OSfunctions This first menu is the main menu. Sometimesthe main tienu will bc a side menu (Step3), but most main menusare bottom menus, TJX 340, TDS 360 & TDS 380 UserManual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com 2. Push a bottom menu button to selecta function, Oneof threethings result: n n n If tbc function bas no subfunctions,it becomesactive. If it is a variable function, you can now use the GeneralPurposeKnob to adjustit (step4). If the function hassubfunctions,they appearon the side menu (step3). The leftmost bottom menu button sometimesactivatesa pop-up menu (as shown in Figure 2-2). You can cycle throughthe pop-upmenu options by repeatedlypressingthe button. Each selectioncrllls up different bottom andside menus, Figure 2-2: A pop-up menu ,,::,: “‘, 3. Push a sick-menu button to select a subfunction. 4. Use the GeneralPurposeKnob to alter variable-functionor subfunction settings. 5. Pressthe CLEAR MENU button to remove a menu from the scn:en. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com TheTDS340,TIX 360,andTDS380comewilh two standard-accessory probes.Usetheseprobesto conductsignalsto theoscilloscope. For detailed probespecifications andinstructions,seetheinstructionmanualpackaged with theprobe. Connecting a Probe Toconnecta probeto theoscilloscope, attachtheBNC endof thepro:bcto &her theCH 1or CA 2 inpul.Be sureto twist theprobeendclockwiseuntil tie BNC is fully locked.SeeFigure2-3. Figure2-3: Connectinga probe Compensating a Probe Usethefollowingprocedure to compensate theprobeeverytim,cyousetupyour oscilloscope. 1. AttachtheprobeBNCconnectorto theCH 1inputandattachtheprobetip 10thePROBECOMPoutputsignalasshownin Figure24. Attach the probesound clip to theouterringof theCH 2 ENC. ‘ES 340, -IDS 360 & ‘IDS 380UserM: Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Figure2-4: Probecompensationsetup 2. PressAUTOSET. The oscilloscopedisplays the compensationwaveform. It should resemblethe waveform shown in Figure 2-5. I I-1 II II 0 0 II 0110 II II 0110 0 Figure2-5: Compensationwaveform TDS 340, TDS 360 & TDS 380 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com 2-I 3 Operating Basics --, - 3. Check that the wavefon indicatescomet compensation.isee Fi-ure 2-h). the wawfm indicates over or undercompensation,use.tie tiigkcnt tool ProvidCdwith the probe10adjust thecompensationas shown in Figure z-7, n 1-L Probecompensatedcorrectly Probeundorcompensaied ns?_ Figure 2-6: How Probe compensation affects signals Figure Z-7: Location of probe compensation adjustment Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com OperatinsBasics Using Autoset The TDS 300 Seriesautosetfeatureproducesa stable,triggereddisplay of almost any input signal. To USCautosct,connecta $@a1 to either the CH 1 or CH 2 input connector,andpressthe AUTOSET button (shown j,n Figure Z-8) Figure 2-8: The AUTOSET button Table 24 specifics the changesautosetmakesin your oscilloscopesetup. table Z-l: Autoset defaults Control Changed by autoset to Selected channel If none already displayed, numetically lowesf of the displayed channels Acauire Mode I Sam& Acquire Stop After RUN/STOPbutton only Display Style vectors Disolav ,, lntensitv , - Overall If less than 50%. set to 75% Display Format Yr Horizontal Position Centered within the graticule window Horizontal Scale 1As determined by the signal frequency Horizontal Ime Base 1Main Only Triqqer Position 1 Unchanged TriggerType Trigger Source Numerically lowest of the displayed channels (the selected channel) Triqqer Level 1 Midpoint of data for the triqqer source Tnsaer Slope I Positive Triaaer Coudina I DC TDS 340,TDS 360 & TDS 380 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com 2-15 ;; I Opcradn,n Basics Table 2-l: Autoset defaults (co,-,t.) Control T$gar Holdoff VerkcalScale - --LYF _I As dehmined by the signal level VerticalCoupling DC unless AC was previouslyset AC remains unchanged vet?iCalBandwidth Full Vertical Offset 0 volts 2-16 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com ppendix A: Specifications This appendix conrains complete spcciftcationsfor the TDS 340, TDS 360, and TDS 380. The specificationsaredivided into threesubsections,one for eachof Characteristics,Typical Churacteriscics, and thm classes of traits: Warrutted Nominal Trails. WarrantedCharacteristics Warrantedcharacteristicsare describedin terms of quantifiable performance limits that *arewarranted.This subsectionlists only warrantedcharacterktics. NOTE In these tables, those warranted characteristics that ore checked in the Pcrformancc Tests,starting on page B-5, appear in boldfnce type under lhe column Name. Performance Conclitions The electrical characteristicsfound in thesetablesof warrantedcharacteristics apply when the oscilloscopehasbeen adjustedat an ambient remperaturc between+20” C and+30” C, hashad a warn-up period of at least20 minntcs, and is operatingat an ambient temperaturebctwcen-10” C and+55’ C (unless 0 I ‘C otherwise noted). 7 Table A-l: Warranted characteristics -signal acquisition system Name Description Accuracy, DC Voltage Measurement, Average Acquisition Mode Measurement type 1DC accuracy Average of 216 waveforms i(2.0% x I(reading - Net Ofketl)l + Offset 1Accuracv+ 0.1 div\ I Delta volts between any two averages of 216 waveforms acquired under the same setup andambient conditions Accuracy, DC Gain, Sample or Average Acquisition Modes 2% Pulse Response, Peak Detect and Envelope Mode SeclDiv setting 5 sldiv - 25 wdiv TDS 340: 10 psidiv - 5 n&v TOS 360: 10 ps/div - 2.5 ns/div TDS 380: 10 psldiv - 1 nsldiv *(2-O% x lreadingl + 0.15 div + 0.3 mV) I Minimum pulse width lone The greater of 10 ns or .OZx se&iv setting TDS 340, TDS 360 & TDS 380 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Appendix A: Specifications -,- TableA-l: Warranted characteristics -signal acquisition system (Cont.) Name Description Accuracy, Offset VoltslLliv setting 1Offset accuracy 2 mVidiv- 99.5 mV/div $491, x INet Offset’l + 3 mV + 0.1 div x Vldiv setting) 100 mV/div - 995 mV/div +_(0.4%x INet Offset’1 * 30 mV + 0.1 div x V/div setting) 1 Vldiv- 10 Vldiv Analog Bandwidth, DC coupled CrossTalk (Channel isolation) Input Impedance, DC-Coupled Input Voltage, Maximum +(0.4%x INet Offset’l t 300 mV + 0.1 div x Vidiv setting) TDS 340: DC - ~100 MHz ,biL f u :,I TDS 360: DC-ZOO MHZ: DC - t180 MHz for 2 mV/div I” \ lTX 380: DC - ?400 MHz; DC - Z2250MHz for 2 mV/div ,,-.-‘5 , I. 21OO:l at 50 MHz with equal Volt&iv settings on each channel lil 0 TDS 340: 1 MR il% in parallel with 20 pF 22.0 pF TDS 360: 1 Mai1 % in parallel with 20 pF k2.0 pF <IL TDS 380: 1 MfI +I% in parallel with 12 pFi2.0 pF LL *300 V (DC or AC) CAT II; derate at 20 dB/decade above 100 kHz to 13 V peakAC!at 3 MHz and above Lower Frequency hmit, AC Coupled2 ’ 510 Hz Net Offset : Offset - (Position x Volts/Div). Net offset is the voltage level at the center of the A-D converter dynamic range. Offset Accuracy is the accuracy of this voltage level. 2 The AC Coupled Lower Frequency limits are reduced by a factor of IO when IOX, passive probes are used. Table A-2: Warranted characteristics-time base system Name Description Accuracy, Long Term Sample Rate and Delay Time *lo0 ppm over any 21 ms interval Accuracy, Delta Xme Measuremems’v 2 For single-shotacquisitions using sample acquisitionmode and a bandwidth limit setting of FULL: i(l WI + 100 ppm x IReadingl t 0.6 ns) For repetitive acquisitionsusing average acquisition mode with 216 averages and a bandwidth limit setting of FULL: 1 2 k(1 WI + 100 ppm x Reading1 c 0.4 ns) For input signals 25 divisions in amplitude and a slew rate of 22.0 diiisionslns at the delta time measurement points. Signal must be acquired at a volts/division setting 25 mV/division. The WI (waveform interval) is the time between the samples in the waveform record. Also, see the footnotes far Sample Rate Range and Equivalent Time or lnferpolated Waveform Rates in Table A-11 on page A-8. TDS 340, TDS 360 & ‘IDS 380 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com n ..+.nnAi.r A. C*nn:cnnr:r.-,. IIDescriotion her Level, DC Coupled dge-Type Trigger, DC bigger source ( Sensitivity 3H1 or CH2 ?(3% of ISetting - Net Offset’1+ 0.2 div x 1voltsldivsetting + OffsetAccuracy) Ztemal f(6% of ISettingl * 20 mV) ~xtemalll0 ?(6% of ISetting + 200 mV) kigger source Sensitivity :Hi or CH2 TDS 340: 0.35 divisionfrom DC to 20 MHz, increasing to 1 div at 100 MHz SDS 360: 0.35 divisionfrom DC to 50 MHz, increasing to 1 div at 200 MHz 1TDS 380: 0.35 divisionfrom DC to 50 MHz. increasing to 1 div at 400 MHz ixtemal TDS 340: 50 mV from DC to 20 MHz, increasing to 150 mV at lC10MHz TDS 360: 50 mV from DC ‘to50 MHz. increasing to 150 mV at 2C’OMHz TDS 380: 50 mV from DC to 50 MHz. ~increasingto5OOmVat4OOMHz .xtemal/l 0 TDS 340: 500 mV from DC:to,20 MHt, increasing to 1.5 Vat 100 MHz TDS 360: 500 mV from DC to 50 MHz, increasing to 1.5 Vat 200 IMHz TDS 380: 500 mV from DC to 50 MHz, increasino to 5.0 Vat 400 MHz MR *2% in parallel with 20 pF 22 pF :300 V (DC or AC) CAT II; demte at 20 dB/decade above 100 kHz to 13 \I peak AC at MHz and above ’ Net Offset: Offset- (Position x Volts/Div). Net Offset is the voltage level at the center of the A-D converter ‘dynamic ~~~“~~~;>~;;;,,~, (; range. Offset Accuracy is the accuracy of this voltage level. ir:‘::~.,,: ,’ ” ,‘+ / ‘,;:F::: ,‘,ii!;re:! ;::‘,, Mle A-4: Power Requirements Name I Descriwtion 90 to 132 VACRM~,continuous range, for47 Hz through 440 Hz power Cons”mptio” p,, range, for47 Hz through 63 Hz 1G5 Watts (120 VA) Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Appendix A: Specifications Table A-5: Warranted characteristics -environmental Name ckscription Atmospherics (TDS 340) 1emperature: -loo C to t55” C, operating: -51 o C to +710 C, non-operating FM&e I humidity: to 95%, at or below t40” C1or to 75% from 141’ C to 455” C rliitude: To 15,000 ft (4570 m). operating; to 40,000 ft (12190 m). non-operating Atmospherics (TDS 360 or TDS 380) bmperature without diskette in floppy disk drive: t4” C to *50” C, operating; -22” C to t60” C. non-operating $mpemture with diskette in floppy disk drive: t10” C to GO0 C, operating or non-operating lelative humidity without diskette in floppy disk drive: to 80% at or below +29” C, or to 20% fmm +30° C to t50” C, operating; to 90% at or below t40” C, or to 5% from +410 C to +SO’ C, non-operating; lelative humiditywith diskette in floppy disk drive: to 80% at or below +29’ C, or to 20% from +30” C to t50” C, operating or non-operating Muda: To 15.000 ft (4570 m), operating; to 40,000 ft (12190 m), nomoperating Dynamics landom vibration without diskette in floppy disk drive: 0.31 g n~s. from 5 to 500 Hz, 10 minutes each axis, operating; 2.46 g RMS,from 5 to 500 Hz, 10 minutes each axis, non-operating Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Appendix A: Specifications -- Typical Characteristics Typical characteristicsare describedin tCrmSof typical or averagepcrformancc. Typical characteristicsare not warranted. Table A-S: Typical characteristics -signal acquisition system Name Description Accuracy,DC Gain, Envelope AcquisitionMode T3% for secidiv settings from 5 SeclDiv to 25 t.rsec/div; &2% for secldiv settings,fmm 10 Hsidivto 5 nsldiv (TDS 340); 12% for secldiv settings from 10 Hsidivto 2.5 nsidiv (TDS 360); k2% for seddiv settinas from 10 us/div to 1 ns/div (TDS 3801 Accuracy,DC Voltage Measurement, Sample AcquisitionMode Measurement type DC accuracy Any Sample k(2.0% x (treading - Net Offset’l) + Offset Accuracy+ 0.13 div + 0.6 mV) Delta Volts between any two samples2 acquired under the same setup and ambient conditions ?(2.0% x treading1+ 0.26 div + 1.2 mV) Frequency Limit, Upper, 20 MHz Eandwidth Limited 20 MHz Step Response Settling Error VoiWDiv setting step amplitude Settling error (%)3 100 ns 20ms 2 mV/div- 99.5 mV/div <2V 51 .o 50.1 100 mV/div - 995 mV/div 520 V 21.5 so.2 1 Vldiv- IO Vldiv 5200 v a.5 SO.2 Common Mode Rejection Ratio (CMRR) 1OO:iat 60 Hz, reducing to 2O:l at SOMHz, with equal VoltslDivand Coupling settings on each channel. 1 Net Offset : Offset - (Position x VoMDiv). Net Offset is the voltage level at the center of the A-D converter dynamic range. Offset Accuracy is the accuracy of this voltage level. 2 The samples must be acquired under the same setup and ambient conditions. 3 The values given are the maximum absolute difference betieen the value at the end of a specified time interval after the mid-level crossing of the step, and the value one second after the mid-level crossing of the step, expressed as a percentage of the step amplitude, TDS 340, TDS 360 & TDS 380 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com A-5 Appendix .-,- A: Specifications Table A-7: Typical characteristics -triggering system requencies above 80 kHz. Attenuates signals below 2 The waveform interval (WI) is the time between the samples in the waveform record. Also see the footnote for the characteristics Sample Rate Rang6 and Equivalent Time or Interpolated Waveform Rates in Table A+ on page A-8. 3 The minimum sensitivity for obtaining a stable trigger. A stable trigger results in a uniform, regular display triggered on the selected slope. The trigger point must not switch between opposite slopes on the waveform, and the display must not “roll” across the screen on successive acquisitions. The TRIG’D LED stays constantly lighted when the SEC/D/DIV setting is 2 ms or faster but may flesh when the SEClOtVsetting is 10 ms or slower. 4 See the characteristic Sensitivify, Edge-Type Trigger, DC Coupledin Table A-3, which begins on page A-3. Ta’ahkA-8; Typical characteristics-probe compensator Name Description Output Voltage and Frequency, Probe Compensator Characteristic output Voltage 5.0 V (low-high) into a 1 MQ load Frequency 1 kHz TDS 340, TDS 360 g: TDS 380 User Manllal Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com rence waveforms, stored setups, and cahbrahon constants are retained when there is no power to the edby a lithium ply-carbon monofluoride battery. traits aredescribedusing simple statementsof fact suchas “Two, identical” for the trait “Input Channels,Number of,” ratherthan in terms of limits that areperformdncc requirements. Nominal Nominal traits-signal acquisition system Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Range, Sample-Rate1~2 TDS 340: 10 Samples/s to 500 MSampiesisin a 1-Z-5 sequence TDS 360: 10 Samples/s to 1 GSampleslsin a i-2-5 sequence TDS 380: 10 Samples/s to 2 GSampiesisin a l-24 sequence Range, Seconds/Div&sion Range, Time Base Delay Sime TDS 340: 5 nsidiv to 5 tidiv in a 1-2.5-S sequence IDS 360: 2.5 nsidiv lo 5 sidiv in a i-2.5-S SPOIIP~I)P TDS 380: 1 ns/div to 5 sidiv in a i-2.5-5 sequence 16.5 ns to 50 seconds Record Length 1,000 samples ’ The range of real-time rates, expressed in samples/second, at which a digitizer samples signals at its; inputs and stores the samples in memory to produce a record of time-sequential samples z The Waveform Rate (WR) is the equivalent sample rate of a waveform record. For a waveform record acquired by real-time sampling Of a single acquisition, the waveform rata is the same as the real-time sample rate; for a waveform created by interpolation of real-time samples from a single acquisition or by equivalent-time sampling of multiple acquisitions, the waveform rate is faster than the real time sample rate. For all three cases, the waveform rata is 14Waveform Interval) for the waveform record, where the waveform interval (WI) is the time between the samples in the waveform record. Table A-12: Nominal traits-triggering system Name Description Range. Hold Off 500 ns minimum to 10 seconds maximum Ranges, Trigger Level SoUrCe Range Any Channel 212 divisionsfrom center of screen External ‘-1.5 Volts ExternalI1 0 +15 Volts tine Formati and Field Rates, Video Ttigger TekProbe interface. ExternalTrigger GO0 Volts Triggers from sync-negativecomposite video, 525 to 625 lines, 50 Hz to 80 Hz, intedaced or noninterlaced systems with scan rates from 15 kHz to 65 kHz - such as NTSC, PAL,or SCAM Level one probe coding Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Description %inch UT.95 cm) diagonal, magnetic deflc . . . . .. phosphor - -. .- _._. ___,., _, J, 640 pixels horizontally by480 pixelsvertically Displayarea is 5.04 inch (12.92 cm) horizontallyby 3.7~” inrh RPpm\ ,,,“,, ICI ,“.““” .,., ~rtidlv .,_..,”-.,, A Sin& araticule 401 x 501 oixels (8 x 10 divisions. that aw nnnroximatelv . . . with divisions -...-rr -., (Icm‘bvicml ’ Nominal traits - VO interface option ( Part of Option 14 I/O interface orTD3F14A 110interface field uuarade kit: comolies with ,I 1 IEEEStd 488-1987 Part of Option 14 110interface or TD3F14A l/O interface field upgrade kit: a g-pin male DTE RS.232 interface that complies with EWTIA 574-90 Part of Option 14 110intetface or T03F14A l/O interface field upgrade kit; a 25qin, IBM 1PC.type, parallel printer interface that complieselectricallywith Centronics C332-44, DB-9 rear panel Video connector; non-intetiaced, with levels that comply with ANSI RS343A VGA compatible at a 30.6 ktlz sync rate Powersupply connector to supply power to the Option 3P Printer Pack Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Appendix A: Specifications -_,, fable A-16: Nominaltraits-mechanical characteristics Standard TDS 340 12.7 kg (28 Ibs) when packaged for domestic shipment Standard TDS 360 or TDS 360 Rackmount TDS 360 or TDS 360 6.6 kg (14.5 Ibs). plus weight of rackmount parts, forTDS 360 or TDS 360 14.7 kg (32.5 Ibs) when the rackmounted TDS 360 orTDS 380 is package shipment Rackmount conversionkit 4.5 kg (10 Ibs); 7.6 kg (17.5 Ibs) when kit is packaged for domestic shipmen Overall Dimensions Standard Instmment (Figure A-l) Height: 191 mm (7.5in) with feet and accessoriespouch installed 165 mm (6.5 in) without the accessoriespouch installed Width: 362 mm (14.25 in) with handle Depth: 471 mm (18.55 in) stand-atone instrument 490 mm (lg.28 in) with front cover installed 564 mm (22.2 in) with handle extended Height: 178 mm (7 in) Width:483mm(19in) Depth: 472 mm (18.6 in) without handles: 517 mm (20.35 in) including handles Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Appendix A: Specilications Figure A-i: TDS 340, TDS 360, and TDS 380 dimensions TDS 340, TDS 360 & TDS 380 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com A-11 -Appendix A: Specifications TableA-lf: Certificationsandcompliances EC Declaration of Conformity Meets intent of Directive8913WEEC for ElectromagneticCompatibilityand Low Voltage Directive 73/23/ECC for Product Safely. Compliance was demonstrated to the following specificationsas listed in the OfficialJournal of the European Communities: EMC Directive39/336/EEC: EN 55011 EN 50081-i Emissions: EN 60555.2 EN 50082-l Immunity: EC 801-Z IEC 801-3 lEC801-4 IEC 601.5 Class B Radiated and Conducted Emissions’ AC Power Line Hanonic Emissions ElectrostaticDischarge immunity RF EleclromagneticField Immunity2 ElectricalFast Transient/BurstImmunity Power Line Surge Immunity Low Voltage Directive 73/23/EEC: EN 61010-l Safety requirementsfor electricalequipment for measurement, control, and laboratory use To maintain emission requirements when connecting to the I/O interface of this oscilloscope, use only a high-qualiv, double-shielded (braid and foil) cable. The cable shield must have low-impedance connections to both connector housings. The VGA cable must also have a ferrite cars at both ends. Acceptable cables are listed in Table C-6 on page C-1. Performance criteria: -0.3 divisionwaveform displacement, or SO.6divisionincrease in p-p noise from 27 MHz to 500 MHz. Test conditions: both channel inputs terminated with grounding caps, both channels set to 10 mV/div, both channels set to DC Coupling, trigger source set to CH 1, acquisition mode sat to Sample, and time base set to 250 ps/div. Underwriters Laboratories listing to Standard Wlil-1 for ElectricalMeasuringand ‘Test Equipment. 34 ’ Canadian Standards Associationcertified to Standard CANICSA-C22.2No. 1010.1-92. 3 1 These standards are North Atnelican interpretations of IEC 1010. Conditions for certification:operating temperature -10” C to +55” C, maximum operating altitude 2000 m, Safety Class I (IEC 1010-I Annex HI. Overvoltaae Cataaow II (IEC 1010-l ” ” ’ ’ Annex J), Pollution Degree 2 (l&S 1010-1). imissions comply with FCC Coda of Federal Regulations 47$Pan 15, Subpart B, ClassA Limits :SA Certification includesthe prod&a and DOWWcords anorooriate for use in the Notth America oower network. All other power cords supplied are approved f&the country of use. ’ FCC Compliance CSACertified Power Cords OvervoltageCategory PollutionOeoree 2 A-l 2 ?ategory: Examples of Productsin this Category: :AT Ill Distribution-levelmains. fixed installation :AT II Local-levelmains, appliances. portable equipment :AT I Signal levels in special equipment or parts of equipment, telecommunications. electronics IO not operate in environments where conductive pollutants may be present. TDS 340, TDS 3GO & TRS 380 User Man@, Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com --~~~~~~ ppendix B: Performance Verification The procedurein this appendixverities that the ‘HIS 340, TDS 360, and TDS 380 oscilloscopesmeet warrantedspecifications.Dcpcnding on what you want to accomplish,you may prefer to perform anotherprocedureyou can find elsewherein this manual. To rapidly conCm th;lt this oscilloscopefunctions,just do the procedures underSe~~.~ts, which begin on page l-5. Advantages: This procedureis quick to do, requiresno externalequipment or signal sources,andperforms extensivefunctional and accuracyrestingto provide high confidencethat the oscilloscopeperforms propefl,y.You can use it as a quick checkbefore making a seriesof important measurements. To further check function&y, do the proceduresunderFunctional Tests chat begin on page l-7. Advantages: Thcsc proceduresrequireminimal additional time to perform, require no additional equipment other thana StandaId-aCCCSSOry probe,and more completely test the internal hardwareof this oscilloscope.You can use them to quickly determineif the oscilloscopeis suitablefor pulting into service,such as whenit is first received, . If you needa more extensivecotirmation of performance,do the Per@rmunch Tesrsin this appendix,beginning on pageB-5, after doing the Functional and .%lfTestr just referenced. Advantages: Theseproceduresadddirect checkingof warrantedspecifications. They requiremvre time andsuitable test equipment.(SeeEquipmcnllt Required on page B-3.) Conventions Throughouttheseproceduresthe following conventionsapply: Each testprocedureusesthe following generalformat: Etle of Test Equipment Required lime Required Prcrcquisites Procedure Refer to Figure B-l: “Main menu” refersto the menu that labels the seven menu buttonsunder the display. “Side menu” refers to the mcnn that labels TDS 340, TDS 360 & TDS 380 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com B-i Verification -AppendixB: Performance thefive buttonsto theright of thedisplay.“Pop-upmenu”refersto a menu thatpopsupwhena mainmenubuttonis pressed. 9 Whereinstnrctcdto usea front-panelbuttonor knob,selectCramamtin or sidemenu,or verify areadoutor status message, thenameof thebuttonor knobappears in boldfacetype. m Inst~ctionsfor menuselectionfollowthisformat:FRONT IPANEL EU1TON -+ Pop-Up(if necessary) -+ Main MenuButton -+ SideMenu Button. Forexample,“PushTRlCGER MENU -+ Type:Video+ ‘fkigger On + Lines.” Pop-UpMenu - Md Menu FigureB-l: Menulocations T’LS 340, TDS 360 & TDS 380 UserManual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Aoucndix B: PerformanceVerification Test Equipment Theseproceduresuseexternal,traceablesignal sourcesto directly check instrument perfotmancc.If your test equipmentdoes,not meet the minimum requirementslisted in Table B-l, your test resultswill be invalid. Table B-i: Test equipment Item number and description Minimum requirements Example Purpose (two required) Impedance 50 R; connectors: female ENC inpuf, male BNC Tektronixpari number 011-0049-01 Checking delaybelween channels 2. Cable, PrecisionCoaxial (Iwo required) 50 0.91 cm (36 in), male to male ENC connectors Tektronixpart number 012-0462-00 Signal interconnec!:ion 3. Connector, D&Banana Female-BNC to dual-banana Tektronixpart number 103-0090-00 Several accuracytests 4. Connector, BNCT Male-BNC to dual-female-BNC Tektronixpart number 103-0030-00 Checking trigger sensitivity 5. Coupler, Dual-Input Female-ENCto dual-male-BNC Tektronixpart number 0670525-02 Checking delay between channels 6. Generator, DC Calibration Vanable amplitude to f110 V; accurecy to 0.1% Wavetek 9100 Calibration System with Oplion 250 Checking DC offset, gain, and measurement accuracy 7. Generator, Leveled Sine Wave, Medium-Frequency 200 kHz to 250 MHz: variable amplitude from 5 mV to 4 Vpp into 50 R Wavetek9100 Calibration System with Option 250 Checking bandwidth and trigger sensitivity 6. Generator, Leveled Sine Wave, High-Frequency’ 200 kHz to 400 MHz; variable amplitude from 5 mV to 4 V,., into 50 n Rohde & Schwarr SMY with URV 35 Power Meter and NRV-Z8 Power Sensor Checking bandwidth and trigger sensitivity 9. Generator,lme Mark Variable marker frequency from 10 ms to 10 ns; accuracy within Wavetek 9100 Calibration System with Option 250 Checking sample rate and delay-lime accuracy A P6109B (TDS &IO), P6111B FDS 360), or P6114E (TDS 360) probe Tektronixnumber P6109B(TDS340),P6111E (TDS 360). or P61148 FDS 380) Signal interconnection 1. Termination 500 10. Probe, 10X. included with this instrument ’ The high frequency leveled sine wave generator is only required to verify the TDS 380, not the TOS 340 or TDS 360. If you use the example equipment, refer to Sine Wave Generator Leveling Procedure on page E-14 for information on obtaining a leveled output from an unleveled sine wave generator, If available, you can use a Tektronix 56504 Leveled Sine Wave Generatior in place of the example equipment. TDS 340, TDS 360 & ‘TDS 380 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com CH2 VOLTYDIV 1V Aat50mV 10mV 5mV +266 mV 154.6 mV -982 mV +314mV +65.4 mV -998 rnv CHI 42.5 mV N/A GH2 ,42.5 mV N/A -2.0 Div +2.0 Div stable trigger stable trigger N/A N/A Analog bandwidth Long term sample rate and delay time accuracy Edge trigger sensitivity, DC coupled Main Ttigger Main Trigger-Falling 1 2 Generator set at -0.6 V. Generator set at -0.9 V. B-4 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com : :;,; Aooendix B: Pcrformarxc Verification Performance Test Overview The proccdurcsarc in threegroupings:Signal Acquisition SystemChecks,?ime Bass SystemChecks,andTriggering SystemChecks.They check ah the characteristicsthat appearin boldface type und&Warranted Characteristicson pageA-l. Prerequisites The testsin this subsectioncomprisean extensive,valid confrrnation of performanceand functionality when the following requirementsare met: The cabinetmust bc installed. You must have performedandpassedthe proceduresunderSelf Tests,on page l-5 and thoseunderFunctional Tests,on page 1-7. The digitizing oscilloscopemust have beenoperatingfor a warm-up period of at least20 minutes, and must bc operatingat an ambient tcrnperature between-10” C and +5S” C. Signal Acquisition System Checks These procedurescheck signal acquisition systemcharacteristicsthat are listed as checkedunder WurrantedCharacteris6icsin the Specificationssccl:ion. CheckDC Voltage Measurement Accuracy n! WARNING.Pe~fom~anceof this procedurerequiresinput voltagestip to 98 VUC. Contact with live circuits could causeinjury or death.Be sure to set the DC calibration generatorto 0 vah bcforc connecting,disconnecting,and/or moving the test hookuadurinz the oerformanceofchis orocedure. Equipment Required: One dual-bananaconnector(Item 3). oneDC calibration generator(Item 6), and oneprecision coaxial cable (Item 2). Time Required: Approximately 35 minutes. Prerequisites: The oscilloscopemust meet the prerequisiteslisted on pageB-5. Procedure: 1. Set the output of a DC calibration generatorto 0 volts. TDS 340. TDS 360 & TDS 380 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com B-5 Verification -Appendix B: Pcrformancc 2. Connecttheoutputof a DC calibrationgenerator througha dual-banana connectorfollowedby a50 8 precisioncoaxialcableto CII 1. asshownin FigureB-2. DC Calibrator Coaxialcable FigureB-2:Hookup for DC voltage measurement accuracy check 3. PressSAVE/RECALL SETUP i Recall Factory Setup + OK Confirm Factory Init. 4. Press ACQUIRE -+ Mode + Average 16. 5. PressMEASURE -t Select Measurement. llllll/ i! 6. Presstic sidemenubuttonmore undlUKmenulabelMeanappears in the sidemenu.PressthesidemenubuttonMean. 7. Setthevertical SCALE to oneof thesettingslistedin TableE-2 thatyou havenot yet checked. (Start with the first setting listed.) 8. PressVERTICAL MENU-t Position 9. TurntheGeneral Purpose Knob to settheverticalpositionto thesetting listedin TableB-2. Thebaseline levelmovesoff screen. 10. Pressthemainmenu button Offset. 11. Use the General Purpose Knob to setverticaloffsetto thesettinglistedin ‘fibk B-2 for thepresentverticalscalesetting.Thebaseline levelremains off screen. B-6 TDS340,TDS360& TDS380UserManual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com 3 Appendix ,_-, B: Performancr:Va’ificution n Table B-2: DC accuracy Vertical scale setting Position setting (divs) Generator settina Offset settina Accuracv limits 1V I +5 I +lOOV 1+98V 1+97-l V to t98.9 V 200 mV I +5 I*1ov I ea.4 v 1t8.28 50 mV I -5 l-l v I-IXV I -581 mV to 419 mV 5mV IO l-l v I -990 mV I -982 mV to -998 mV V tot8.52V 12. Set the generatorto the level and polarity indicated in Table B-2 for the vertical scale,position, and of&t settingsyou havemade.The DC test level should appearon screen.(Ifit dots not rctum, the DC accuracycheekhas failed for the presentvertical scalesetting of the currentchannel.) 13. Check that the readoutfor the measurementMean readouton screenis within the limiti listed Forthe presentvertical scaleand position/offsct/gcnerator settings. 1,4. Repeatsteps7 through 13 until you have checkedall the vertical scale settingslisted in Table B-2. Recordthe measurementsfor eachof the 50 mV settings. 15. Subtract the second50 mV measurementfrom the first and comparethe result to the “A at 50 mV” limits in Table B-2. :16. Press WAVEFORM 17. OFF; then,pressCH 2 Set the generatoroutput to 0 V. 18. Move the test hookup to the CH 2 input. 19. Repeatsteps5 through I5 for channel2. 20. Set the generatoroutput to 0 V, 2X. Disconnect the cable at the CH 2 input connector. DC Gain Accuracy Offset Accuracy i DC gain accuracyis verified by successfulcompletion of the self tesI:s and the DC voltage measurementaccuracy(in the previous procedure). Offset accuracyis verified by successfulcompletion of the Self Testsandthe DC voltage measurementaccuracy(in the previous proccdurc). TDS 340, TDS 360 & ‘I’D.5380 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com B-7 precisioncable(ItemZ), and one50B termination(Item 1). TimeRequired:Approximately 20 minutes. Prerequisites:SeepageB-5. Procedure: 1. Connect,througha 50 !J precisioncableanda 50 9 terminalion, thesine waveoutputof a kvekd sinewavegenerator to CH 1 (seeFigureB-3). Set theoutputof thegeneratorto a reference frequencyof 50Hz. NOTE Iiyou areverifying a TDS 380, you needa leveledsine wavegenerator wit/za 400MHz oztputfrequency.He&rto SineWaveGenerator Leveling Procedure on pageB-14jbr in@wation on obtaining a leveledoutput&m, an unlcvekd sine uwe generam L Leveled Sine Wave Generator owul b- SO R Terminalion Figure B-3: Hookupfor analogbandwidthcheck 1. PressSAVE/lZECAI,LSETUP+ RecallFactorySetup-+ OK Confirm FactoryInit. 2. SetthehorizontalSCALEJO10ps/div. 3. PressTRIGGER MENU -+ Coupling-+ NoiseRej. 4. PressACQUIRE + Mode+ AverageX6. 5. PressMEASURE-+ High-Low Setup-+ Min-Mar. 6. PressthemainmenubuttonSelectMeasurement.Now pressthesidemenu buttonmore untilthemenu labelPk-Pkappears in thesidemenu.Pressthe sidemenubuttonPk-Pk. 7. SettheverticalSCALEto 10mV/div. TDS340,TDS360& TDS380UserManual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Appendix B: PerformanceVerification 8. Set the generatoroutput so the CHx Pk-Pk readoutequals60 :mV. 9. PressSET LEVEL TO 50% as necessaryto trigger the display. 10. Increasethe frequencyof the generatoroutput to 100 MHz (TDS 340), 200 MHz (TDS 360). or 400 MHz (TDS 380). 11. Set the horizontal SCALE to 5 ns/div (TDS 340), 2.5 ns/div (TDS 360), or 2.5 ns/div (TDS 380). 12. PressSET LEVEL TO 50% as necessaryto trigger the display. 13. Cheek that the Pk-Pk readouton screen(as shown in Figure B-l) is 2 42.5 mV First. increase the reference frequency IDrhe fesl frequency; then decrease the horizontal scale. Second. read Ihe resutls from the readout of measuremenf Pk.Pk. FigureB-4: Measuringanalogbandwidth 14. When fmishcd checking,set the horizontal SCALE back to the 10 @div setting, and set the generatoroutput frequency back to 50 kHz. 15. PressWAVEFORM OFF to remove Channel 1 from the display. 16. PressCH 2 and move the hookup to the CH 2 input. 17. PressTRIGGER MENU + Source + CH 2. 18. Repeatsteps6 through 13 for CH 2. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com AppendixB: Performance Veritication -,I_ 19. Disconnect thetesthookup from theCH 2 inputconnector. Time BaseSystemChecks Thisprocedure chec!~thosecharacteristics that.relateto theMainandDelayed time basesystemandarelistedascheckedunder Warrankd Chamctoirtics in theSpcci$cations section. Check Long-Term Sample Rate and Delay Time Accuracy EquipmentRequired:Onetime-markergenerator(Item9), oneprecision coaxialcable,(Item2) andone50 Q termination(Item 1). Time Required:Approximntcly5 minutes. Prerequisites:SeepageB-5. Procedure: 1. Connect,througha 50 Q precisioncoaxialcableanda50 Q termination,the time-mtukoutputof a time-markergenerator to CH 1, asshownin Fibwe B-5. Settheoutputof thegeneratorfor 10msmarkers. bl - SO II Termioafion Figure B-5: Hookupfor sampleratecheck 2. PressSAVE/RECALLSETUP-+ Recall FactorySetup-+ OK Confirm FactoryInit. 3. SettheverticalSCALEto 500mV/div. 4. PressSETLEVEL TO ,SO%:usethevcrticti POSITION knobto center thetestsignalonscreen. 5. SetthehorizontalSCALEto 1 ms/div. 6. PXSSHORIZONTAL MENU-t Trigger Position-t Setto 10%. TDS340,TDS360& TDS380UserManual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Appendix B: PerformanceVcrii%at,ion 7. Adjust the horizontal POSITION to move the trigger T to the right andon to the screen.Continue to position the trigger T to align it to the cenler vertical gaticulc lint. x. Pressthe main menu button Time Rase;thenpressthe side menu button Delayed Only. Y. Set the hodzontal SCALE of the D (delayed)time baseto 1 ms/div. Then usechcGeneral Purpose knob to set delay time to 10 ms. ‘10. Set the horizontal SCALE of the D (dclaycd)time baseto 500 ns/div. NOTE Whenyou changethe SECDIV in step 10, the delay time readout changesto IO.00001or 9.99999.This is normal and has rzza effecton the verijication 11. Check that the rising edgeof the marker crossesthe centerhorizontal graticule line at a point within ti.0 divisions of the gratlcule cerner. NOTE Onedivision ofdisplacementfrom the centergraticule correspondsto a SOppm time baseerrox 12. Disconnectthe test hookup. DeltaTimeMeasurement Della time measurcmcntaccuracyis verified by successfulcompletion of the Accuracy previousprocedure. Trigger System Checks Theseprocedurescheck thosecharacteristicsthat relate to the trigger systemand arelisted as checkedunder WarrantedCharacteristicsin the Spccificacnlions section CheckEdgeTrigger Sensitivity,DCCoupled Equipment Required: One leveled sine wave gcncrator(Item 7 or 8), two precision 50 SZcoaxial cables(Item 2), one 50 Q tcrmlnation (Item I), andone BNC T connector(Item 4). Time Required: Approximately 10 minutes. Prerequisites: SeepageB-5. TDS 340, TDS 360 & ‘IDS 380 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com B-11 Verification -,AppendixB: Performance 1. PressSAVE/RECALLSETUPJ RecallFactorySetup+ OK Confrm FactoryInit. 2. SettheverticalSCALE to 500mV/div. 3. Settie horizontalSCALEto 10n&iv. 4. PressTRIGGER MENU + Made-+ Nnmal. 5. PressACQUIRE -t Mode-+ Average16. 6. Connectone50 Q cableto theoutputof thesinewavegenerator. Attacha BNC T connectortv theotherendof thecable.Connecta second50 Q cable to theochersideof theBNC T connector. 7. ConnecttheBNC T connectorto CH 1; connecttic cableto theEXTTRIG inputthrougha 50 9 terminationasshownin FigureB-6. ToEfl Trigger 50 n Terrninah FigureB-6:Hookup for triggersensitivitycheck 8. Scrthegeneratorfrequencyto 100MHZ (Trx 340).200MH;: (TDS360).or 400 MHZ (TDS 3SO). 9. PressMEASURE-t High-Low Setup-+ Min-Max 10. PressthemainmenubuttonSelectMeasurement. 11. Pressthesidemenubutton-more- until Amplitudeappears in theside menu.PressthesidemenubuttonAmplitude. 12. PressSETLEVEL TO 50%. 13. Setthetestsignalamplitudefor aboutonedivisiononscreen,Fineadjustthe generator outputuntil theCH I Amplitudereadoutindicates theamplitude is 500mV.(Readoutmayfluctuatearound500mV) 14. PressTRKGGERMENU + Slope. TDS 340, ‘IDS 360 & TDS380UserManual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com 15. PKSSSET LEVEL TO 50%. Check that a stabletrigger is obtainedfor the test waveform on both the positjve andnegativeslopes(seeEi~uccB-7). (Use the side menu to switch betweentrigger slopes;usethe trigger LEVEL knob to stabilize the trigger if required.) ,. Second, checkfor a Sable-’ ’ FigureB-7: Measuringtrigger sensitivity X6. PressWAVEFORM OFF. 17. PressCH 2. 1X. PressTRIGGER MENU + Source + Ch2. 19. Disconnectthe hookup from CEI 1 andcormectit to CH 2. 20. Set the vertical SCALE to 500 mV/ciiv. 21. RepeatstepsI4 and 15 for Channel2. 22. PressTRIGGER MENU -3 Source + EXT/lO. 23. PressMEASURE + Select Measrmnt + Amplitude. 24. Incrcascthe generatoramplitude until the amplitude measurementreads 1.5 V if you are checking a IDS 340 or TDS 360. Increasethe generator amplitude until the amplitude measurementreads4.0 V if you are checking a TDS 380. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com 1,. Connectthe equipmentas shown in Figure B-8. 2. Set the sine wave generatorto a referencefrequencyof 50 Wz. 3. me sine wave gcncramr amplitude to tic requirednumberof divisions as measuredby the oscilloscope. 4. Note the reading on the level meter. 5. Changethe sine wave generatorto the desirednew frequency. 6. Input the correction factor for the new frequencyinto the level meter. I. ,&djuS[ Adjust the sine wave _~cncrabr amplitude until the level mMH again the value notedin step4. The signal amplimde is now correctly set new frequency. B-14 TDS 310, ‘IDS 360 & TD: Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Appendix 6: Pcrfomance Vetification FigureB-8: Hookupfar sine wave generatorleveling ‘IDS 340, TDS 360 8~TDS 380 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com This appendixdcscribcsthe various options as well asthe standardand optional accessuriesthat areavailable for the TDS 340. TDS 340, andTDS 380. Options Options include the following. Option14: l/O Interfaces This option includes GPIB, RS-232, and Centronicsinterfaces,VGA video output, and power for the DPU 411 printer. It also includesthe TDS 340, TDS 360 & TDS 380 Programmer Manual. You can connecta remotedisplay to the VGA 9.pin D cotmccmr on the rear panel. Table C-6 on pageCA gives the part numberof a properly shielded cable that is commercially available. Becausedisplay manufacturersuse diffcrcnt pin combinationsand connectors, you may find Ihe information in Table C-l helpful. Table C-l: VGA output connector pins Pin Signal 2 1Video (monochrome analog) I 4 1Horizontal sync @ 31.5 kHz (VGA rate) 5 I Verticalsync I 6. 7.6 OptionsAi-AS: InternationalPowerCords Ground Besidesthe standardNorth American, 110V, 60 Hz power cord, Tektronix ships any of five alternatepower cord configurationswith the oscilloscopewhen ordcrcd by the customer(seeTable C-2). Table C-2: International TDS 340, TDS 360 & TDS 380 powercords Option Al Power Cord Universal European - 220 V, 50 Hz A2 UK- 240 V, 50 Hz A3 Australian- 240 V, 50 Hz user hhnUd Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com -AppendixC: OptionsandAccessories Table C-2: international LanguageOptions power cords (Cont.) Option Power Cord A4 North American - 240 V.60Hz A5 Switzerland - 220V,50Hz .. Language optionsprovideuserdocumentation in followinglocallanguages (see TableC-3 for optionsandmanualpartnumbers): Table C-3: Language options Warranty-Plus Service Options User manual Language option / Language Std I”1 L3 L4 L5 L7 LR LQ English French 1Gem-w Spanish Japanese Simple Chinese Standarc! Chinese Korean / 070-9459-u 070.9431 -xx I 070-9432-u 07O+I33~xy 070-9440-Xx 070.Q&7-xx ,.~ 070.9438-Xx 070.9439xX Reference 070.94wxx 070.9441-XX Thek~hwin~ optionsaddto theservicesavailablewith thesYdndard, warranty. (Thestandardwarrantyappears immediatelyfollowingthetitle pagein this manual.) n n n OptionM2: Tektronixprovidestbrceyearsof warrantyplustwo years remedialservice. Option M3: Tektronix providestbrceyearsof warrantyplustwo years remedialserviceandfourOscilloscope calibrations. OptionM8: Tektronixprovidesfour calibrations andfour performance verifications,oneof eachin the secondthroughthefifth yearsof service. TDS 340,‘IDS 360& TDS380UserManual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Accessories The standardaccessorieslisted in Table C-4 come with the TDS 340, TIE 360, andTDS 380. (Refer to Table C-3 for manual part numbers.) Table C-4: Standard accessories ACCWOry Reference User Manual U.S. Power Cord Probes (quantity two) PGIOSB10X Passive (TDS340) Probes (quantity two) P611lB 10X Passive(TDS 360) Probes (quantihtwo) P6114B 10X Passive (TDS 380) ional Accessories You can order the optional accessorieslisted in Table C-5. Table C-5: Optional accessories Accessory Part number Scope Camera C9. Option 4, (includesAdapter Hood 016-1154-01) OscilloscopeCart Rackmount Kit (for field conversion) 016-1166-00 Soft-Sided CarryingCase 016-1156-01 Carrying Case 016-0792-01 Deluxe Transit Case 016-1157~00 Front Cover 200-3232-02 AccessonesPouch 016-1159.00 I/O Interface Field Upgrade Kit TD3F14A Docuwave waveform capture utilitysoftware for the PC S60 DWAV Printer,bubble-jet, 360 dpi, 63 cps, plain paper HC 220 Printer,portable thermal, 112 mm paper DPU 411 Paper for DPU 411 minter. package of five Tolls I 006-7560.00 Programmer Manual 1070.9442-xX Service Manual I 070”9435-XX Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Appendix C: Options and Accessories Accessory Probes Thesearc other types of probesyou can use with the TDDS340,TDS 360, and TDS 380. You can orderthe following probesseparately: I n P61OlB 1X PassiveProbe P6129B Switchable 1X-10X PassiveProbe(not recommendedfor the TDS 360 or TDS 380) n P6408 ‘IT Logic Probe n PS 100 High Voltage Probe q P5200 High-Voltage Differential Probe m AM503S DC/AC Current ProbeSystem m P6561AS SMD Small-Geometry Probe Accessory Cables Table C-6 lists cables you can use with the TDS 340, TDS 360, and‘IDS 380. You can order them separately. TableC-6: Accessorycables Cabletype Part number GPIE.1 meter (3.3 feet) 012-0991-01 GPIE, 2 meter (6.6 feet) K-232, e-pin female to g-pin female connectors, null modem, 76 inch (for AT style computers) RS-232. g-pin female to 25pin female connectors, null modem, 76 inch (for PC style compwers) K-232, S-pinfemale to 25pin male connectors, null modem, 9 feet (forserial interface plinks) 012.1298-00 135-232. g-pin female to 25.pin male connectors, 15 feet (for modems) Centronics, 25.pin male to 36.pin Centronics, 2.4 meter (8 feet) (for parallel printer interfaces) 012.1214-00 NEW VGA video cable. (Use an appropriate adapter when other than a e-pin monitor connection is needed.) TDS 340, TDS 360 & TDS 380 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com User ManUd D: General Care and Cleaning Protect tic oscilloscopefrom adverseweatherconditions.The oscilloscopeis not waterproof. A! CAUTION.To avoid damageto the oscilloscope,do not exposeit to sprays, liauids. or solvennt~. Inspectthe oscilkcope as often as operatingCOnditionS oscilloscopeexterior,perform the following steps: A! rCqUire. To clean the 1. Remove loose dust on the outsideof the oscilloscopewith a lint-free cloth. Use careto avoid scratchingtic clear plastic display filter. 2. Use a soft cloth or papertowel dampcncdwith waterto cleanthe oscilloscope.You can use a 75% isopropyl alcohol solution for more efficient cleaning. CAUTION.i71awid damageto the surfhce of the oscilloscope,do not USL’nny abrasive or chemical cleaninn apent,s. 3&l DS 380 User Mzmual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment • FAST SHIPPING AND DELIVERY • TENS OF THOUSANDS OF IN-STOCK ITEMS • EQUIPMENT DEMOS • HUNDREDS OF MANUFACTURERS SUPPORTED • LEASING/MONTHLY RENTALS • ITAR CERTIFIED SECURE ASSET SOLUTIONS SERVICE CENTER REPAIRS Experienced engineers and technicians on staff at our full-service, in-house repair center WE BUY USED EQUIPMENT Sell your excess, underutilized, and idle used equipment We also offer credit for buy-backs and trade-ins www.artisantg.com/WeBuyEquipment InstraView REMOTE INSPECTION LOOKING FOR MORE INFORMATION? Visit us on the web at www.artisantg.com for more information on price quotations, drivers, technical specifications, manuals, and documentation SM Remotely inspect equipment before purchasing with our interactive website at www.instraview.com Contact us: (888) 88-SOURCE | [email protected] | www.artisantg.com