Download Diagnostics Manual - Service, Support
Transcript
Overview of Alarms 03/2009 NCK alarms 16949 Correspondence between marker of channel %1 and channel %2 is invalid. Parameters: %1 = Channel ID %2 = Channel ID Definitions: This channel defines a WAIT marker with other channels, which on their part have no correspondence with this wait marker. This channel's WAIT marker has no explicit counterpart in the other channel; i.e. the channels do not mutually wait. ============================================================ Example Ch 3Ch 5Ch 7 WAITM(99,3,5) WAITM(99,3,5) WAITM(99,5,7) The wait markers in channels 3 and 5 mutually wait for each other and channel 7 only waits for channel 5. Therefore, channel 7 may continue when 5 and 7 have reached the wait marker, but channel 3 is still far in front of the wait marker. When it continues, channel 7 deletes its wait marker. When wait marker 99 is reached again, you can no longer determine the behavior precisely. ============================================================ Reaction: Alarm display. Remedy: In each wait marker, list all channels with which you want to synchronize, or suppress the alarm with MD11410 $MN_SUPPRESS_ALARM_MASK, bit 23. ============================================================ Sample solution A: Ch 3Ch 5Ch 7 WAITM(99,3,5,7) WAITM(99,3,5,7) WAITM(99,3,5,7) ============================================================ Sample solution B: Ch 3Ch 5Ch 7 WAITM(99,3,5) WAITM(99,3,5) WAITM(88,5,7) WAITM(88,5,7) ============================================================ Sample solution C: Ch 3Ch 5Ch 7 WAITM(88,5,7) WAITM(88,5,7) WAITM(99,3,5) WAITM(99,3,5) Program Continuation: Clear alarm with the Delete key or NC START. 16950 [Channel %1: ] Search run with hold block Parameters: %1 = Channel ID Definitions: Informational alarm. The search run was not performed on the interruption block, instead, it touches down shortly before that. This so-called "hold block" is generated by the part program command IPTRLOCK, or implicitly defined by MD22680 $MC_AUTO_IPTR_LOCK. This is to prevent you from performing a search run in critical program areas (e.g. gear hobbing). The alarm also displays that, instead of searching for the block that actually was interrupted before, another block is being searched for. This behavior is desired and the alarm serves only informational purposes. Reaction: Alarm display. Remedy: MD11410 $MN_SUPPRESS_ALARM_MASK, MD22680 $MC_AUTO_IPTR_LOCK and language command IPTRLOCK Program Continuation: Clear alarm with the Delete key or NC START. 16951 [Channel %1: ] Search run in a protected program section. Parameters: %1 = Channel ID Definitions: A part programmer can define protected part program sections with the language commands IPTRLOCK and IPTRUNLOCK. Every search run in these program sections will then be acknowledged with alarm 16951. In other words: When the alarm appears, the user has started a search run (Serupro type) and the search target lies in a protected area. A protected area can also be defined implicitly with the MD22680 $MC_AUTO_IPTR_LOCK. 2-284 © Siemens AG, 2009. All Rights Reserved SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Related documents
Manual de diagnósticos - Industry Support Siemens
Manual de diagnóstico Alarmes
Manual de diagnóstico, Alarmes - Service, Support
Manual de diagnóstico, Alarmes - Service, Support
Display - Internet
Manual de diagnóstico, Alarmes - Service, Support
Programming Manual Measuring cycles HMI sl
COMP-MALL GmbH www.comp
Manuale utente
List Manual G120C - Service, Support
List Manual G120C
Siemens SINUMERIK 802D sl Operator`s manual