03/2009 Overview of Alarms SINAMICS-Alarms Remedy: 201421 Adapting the topologies: - check the component soft-wired connections against the hardware configuration of the drive unit in the commissioning software and correct differences. - parameterize the topology comparison of all components (p9906). - parameterize the topology comparison of one components (p9907, p9908). Note: Under "Topology --> Topology view" the commissioning software offers improved diagnostics capability (e.g. setpoint/actual value comparison). <location>Topology: Comparison different components Message value: Component number: %1, component class target: %2, component class actual: %3, fault cause: %4 Drive object: All objects Reaction: NONE Acknowledge: NONE Cause: The topology comparison has detected differences in the actual and target topologies in relation to one component. The component class, the component type or the number of connections differ. Alarm value (r2124, interpret hexadecimal): ddccbbaa hex: aa = component number of the component, bb = component class of the target tolopology, cc = component class of the actual topology, dd = fault cause dd = 01 hex = 1 dec: Different component class. dd = 02 hex = 2 dec: Different component type. dd = 03 hex = 3 dec: Different Order No. dd = 04 hex = 4 dec: Different number of connections. Note: Component class, component type and connection number are described in F01375. The drive system is no longer booted. In this state, the drive control (closed-loop) cannot be enabled. Remedy: Check the component soft-wired connections against the hardware configuration of the drive unit in the commissioning software and correct differences. Note: Under "Topology --> Topology view" the commissioning software offers improved diagnostics capability (e.g. setpoint/actual value comparison). 201425 <location>Topology: Comparison serial number of a component is different Message value: Component number: %1, Component class: %2, Differences: %3 Drive object: All objects Reaction: NONE Acknowledge: NONE Cause: The topology comparison has detected differences in the actual and target topologies in relation to one component. The serial number is different. Alarm value (r2124, interpret hexadecimal): ddccbbaa hex: cc = number of differences bb = component class aa = component number of the component Note: The component class is described in F01375. The drive system is no longer booted. In this state, the drive control (closed-loop) cannot be enabled. © Siemens AG 2009 All Rights Reserved SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009 2-663
Related documents
Manual de diagnósticos - Industry Support Siemens
Manual de diagnóstico Alarmes
Manual de diagnóstico, Alarmes - Service, Support
Manual de diagnóstico, Alarmes - Service, Support
Display - Internet
Manual de diagnóstico, Alarmes - Service, Support
Programming Manual Measuring cycles HMI sl
COMP-MALL GmbH www.comp
Manuale utente
List Manual G120C - Service, Support
List Manual G120C
Siemens SINUMERIK 802D sl Operator`s manual