Download Diagnostics Manual - Service, Support
Transcript
Overview of Alarms 03/2009 SINAMICS-Alarms Remedy: 201386 Adapting the topologies: - undo the change to the actual topology by changing over the DRIVE-CLiQ cables. - commissioning software: Go online, upload the drive unit, adapt the topology offline and download the modified project. - automatically remove the topology error (p9904). Note: Under "Topology --> Topology view" the commissioning software offers improved diagnostics capability (e.g. setpoint/actual value comparison). <location>Topology: Comparison DRIVE-CLiQ component shifted Message value: Component number: %1, Component class: %2, Component (target): %3, Connection number: %4 Drive object: All objects Reaction: NONE Acknowledge: NONE Cause: The topology comparison has detected a DRIVE-CLiQ component in the actual topology that has been shifted with respect to the target topology. Alarm value (r2124, interpret hexadecimal): ddccbbaa hex: dd = connection number cc = component number bb = component class aa = component number of the component shifted in the target topology Note: The connection in the actual topology where the shifted component was detected is described in dd, cc and bb. Component class and connection number are described in F01375. The drive system is no longer booted. In this state, the drive control (closed-loop) cannot be enabled. Remedy: Adapting the topologies: - undo the change to the actual topology by changing over the DRIVE-CLiQ cables. - commissioning software: Go online, upload the drive unit, adapt the topology offline and download the modified project. - automatically remove the topology error (p9904). Note: Under "Topology --> Topology view" the commissioning software offers improved diagnostics capability (e.g. setpoint/actual value comparison). 201387 <location>Topology: Comparison option slot component shifted Message value: Component number: %1, Component class: %2, Component (target): %3, Connection number: %4 Drive object: All objects Reaction: NONE Acknowledge: NONE Cause: The topology comparison has detected a option slot component in the actual topology that has been shifted with respect to the target topology. Alarm value (r2124, interpret hexadecimal): ddccbbaa hex: dd = connection number cc = component number bb = component class aa = component number of the component shifted in the target topology Note: The connection in the actual topology where the shifted component was detected is described in dd, cc and bb. Component class and connection number are described in F01375. The drive system is no longer booted. In this state, the drive control (closed-loop) cannot be enabled. 2-660 © Siemens AG 2009 All Rights Reserved SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Related documents
Manual de diagnósticos - Industry Support Siemens
Manual de diagnóstico Alarmes
Manual de diagnóstico, Alarmes - Service, Support
Manual de diagnóstico, Alarmes - Service, Support
Display - Internet
Manual de diagnóstico, Alarmes - Service, Support
Programming Manual Measuring cycles HMI sl
COMP-MALL GmbH www.comp
Manuale utente
List Manual G120C - Service, Support
List Manual G120C
Siemens SINUMERIK 802D sl Operator`s manual