Overview of Alarms 03/2009 HMI-Alarms Definitions: The drive unit with the bus number and slave address specified in the alarm is in 'First commissioning' state. Reaction: Alarm display. Remedy: Execute first commissioning for the affected drive unit. To do so, switch in the HMI to the dialog 'First commissioning > Drive system > Drive unit, select the affected drive unit, and follow the instructions of the HMI. Program Continuation: Internal 120403 Bus%1.Slave%2: %3: Check/acknowledge topology! Parameters: %1 = Bus number %2 = Slave address %3 = Name of the affected drive unit Definitions: The drive unit with the bus number and slave address specified in the alarm has detected an illegal difference between reference topology and actual topology during the ramp-up when checking the DRIVE-CLiQ topology. For this reason, the drive unit has stopped the ramp-up in the 'Topology error' state. Reaction: Alarm display. Remedy: - Check actual topology and possibly replug in line with the actual topology. - Check DRIVE-CLiQ cables for breakage and problems with contacts. - Test DRIVE-CLiQ components for operational functioning. Note: Under 'Commissioning > Drive system > Drive unit > Topology', HMI offers a suitable diagnosis (e.g. reference/actual value comparison). Program Continuation: Internal 120404 Setting up acyclic link %1 failed.%nSwitch off/on control, drives and HMI. Parameters: %1 = Name of connection Definitions: Setting up an acyclic link with a drive unit for file transfer from/to this drive unit has failed. The file could not be transferred from/to this drive unit. The affected drive unit has the bus number and slave address specified in the link name: /DRIVE_<Bus number>_<Slave address>. Reaction: Alarm display. Remedy: Execute the following measures in the sequence specified until the process leading to the alarm can be repeated successfully: 1. Switch off/on control, drives and HMI, and then repeat the process leading to the alarm. 2. Load PROFIBUS configuration (HW Config) with same PLC and CP-Subnet-ID in PLC and CP, switch off/on control and HMI, and then repeat the process leading to the alarm. 3. Return to factory settings of the affected drive unit, switch off/on control, drives and HMI, and then repeat the process leading to the alarm. 4. Contact Siemens AG, Industry Sector, I DT MC, Hotline (Phone/Fax: see Alarm 1000) regarding the error text. Program Continuation: Internal 120405 SINAMICS: Firmware update for DRIVE-CLiQ components is running.%nPlease wait for the firmware update to be completed! Definitions: The firmware update is being executed for at least one DRIVE-CLiQ component. Reaction: Alarm display. Remedy: None required. Please wait for the firmware update to be completed. Completion of the firmware update is signaled by alarm 120406. Program Continuation: Internal 120406 SINAMICS: Firmware update of DRIVE-CLiQ components completed.%nSwitch off/on drive system! Definitions: Firmware update of all DRIVE-CLiQ components completed. Reaction: Alarm display. 2-620 © Siemens AG 2009 All Rights Reserved SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Related documents
Manual de diagnósticos - Industry Support Siemens
Manual de diagnóstico Alarmes
Manual de diagnóstico, Alarmes - Service, Support
Manual de diagnóstico, Alarmes - Service, Support
Display - Internet
Manual de diagnóstico, Alarmes - Service, Support
Programming Manual Measuring cycles HMI sl
COMP-MALL GmbH www.comp
Manuale utente
List Manual G120C - Service, Support
List Manual G120C
Siemens SINUMERIK 802D sl Operator`s manual