Download ISDN Basic Rate Interface Feature Fundamentals

Transcript
330 ISDN BRI features
Meridian Mail Trunk Access Restriction
This feature does not support Call Transfer from ISDN BRI sets.
Message Center
A call originating by an ISDN BRI terminal to a non-ISDN BRI terminal
can be redirected to Network Message Service - Message Center. The
associated MIK/MCK and the lamp states are not supported for the
corresponding ISDN BRI terminal.
Multifrequency Compelled Signaling features
R2 and MFC signaling on DID and TIE trunks This feature allows
line and register signaling on DID and TIE trunks, using an MF sender
and receiver card. Each forward signal sent to the Central Office is
acknowledged by a backward signal. This feature also allows the system
to request Calling Number Identification (CNI) information, to be shown
on the originating terminal’s display.
The register signaling part of this feature is supported for ISDN BRI. The
CNI display is not supported.
Multifrequency Signaling for Socotel (MFE) Multifrequency Signaling
for Socotel (MFE) is similar to R2 Multifrequency Compelled (MFC)
Signaling, but is not compelled in the same way. Instead of each signal
being answered by another signal of some meaning, each signal is
answered by a control frequency which indicates to the other end of the call
that the signal has been received and its transmission can cease. In this
way, signals can originate at either end of the call.
R2 MFC Signaling operates by answering each forward signal from
the originating end, with a backward signal from the terminating end.
Each signal must be interpreted using the appropriate table. Unlike R2
MFC Signaling, backward and forward signals use the same frequency
combinations. The need for the concept of an incoming or outgoing
sender/receiver is replaced by an MFE sender/receiver, which can act in
both directions during any single call.
Pulsed signals, which are used in R2 MFC Signaling to indicate a message
being initiated from the CO which normally replies, are no longer necessary
with the new MFE card.
The sequence of messages sent to and received from the CO is transparent
to the ISDN BRI terminal.
Multiple Appearance Directory Number
Multiple ISDN BRI terminals on the same DSL can have the same DN. An
ISDN BRI and a non-ISDN BRI terminal cannot have the same DN.
Nortel Communication Server 1000
ISDN Basic Rate Interface Feature Fundamentals
NN43001-580 01.02 Standard
Release 5.0 20 June 2007
Copyright © 2003-2007, Nortel Networks
.