Download NWare Device Reference - Peavey Digital Research

Transcript
NWare Device Reference
to receive.
Tip: Values in the Sub-Channel Mapping boxes may be
changed on a dynamic basis. This allows any hardware channel
number to be mapped to any bundle sub-channel(s) at any time,
greatly expanding signal routing flexibility. However, only
users familiar with advanced CobraNet practices should use
this feature.
Priority
The priority of the group of sub-channels.
Tip: You can use the priority setting to implement a
redundancy system for transmitters. Specify the priority for a
row and then, on a second device, specify the same settings, but
use a lower priority. If the transmission of the first row fails, the
lower priority row will be transmitted.
GPIO
Digital Ins
Pin x
Lit (green) when digital input is detected on the pin.
Digital Outs
Pin x
Click to enable digital output on the pin.
Clock Outputs
Word clock
Click to enable NION word clock output on pin 6 for
synchronization of external devices.
The sample rate used for this clock is the sample rate specified
for the project you are running on the NION. To view the
project sample rate, on the File menu, click Project Properties.
Frame clock
Click to enable NION frame clock output on pin 7 for
synchronization of external devices.
Vector clock
Click to enable NION vector clock output on pin 8 for
synchronization of external devices.
Analog Ins
Value
May 28, 2015
Displays a representation of the input voltage level range. The
minimum value is represented by zero and the maximum by
1.0.
Version 1.7.2.3
99