Download Merlin Legend R1 Installation Programming and Maintenance

Transcript
Maintenance and Troubleshooting
Table 5-2 Continued
Error
Code
Screen
Description
840C
STUCK
RINGING
Possible Cause
■
■
Continuous ringing
from CO
AC power cross
Solution
Swap positions of
similar line/trunk and
station modules. If
problem follows
module, replace
line/trunk and station
module. If problem
stays at that position,
test line/trunk.
840D
INCORRECT
FIRMWARE
STATE
■
Incorrect system
module firmware
state
Turn power off for at
least 1 second and then
back on. Repeat
system programming
procedure. If problem
persists, replace
Iine/trunk and station
module.
840E
TRK UPLINK
MESSAGE
ERROR
■
Unrecognized
message from the
processor module to
the line/trunk and
station module
Turn power off for at
least 1 second and then
back on. Repeat
system programming
procedure. If problem
persists, replace
line/trunk and station
module.
Troubleshooting 5-57