Download OpenPowerNet User Manual

Transcript
OPN/51/1.5.3
Page 190 of 232
User Manual
Issue 2014-11-05
<ConductorFrom condName="TSS_5_F_r" lineID="A" trackID="1" km="5.3" />
<ConductorTo condName="CW" lineID="A" trackID="1" km="5.3" />
</Connector>
<Connector name="" z_real_Ohm="0.001" z_imag_Ohm="0">
<ConductorFrom condName="TSS_5_RF_l" lineID="A" trackID="1" km="4.7" />
<ConductorTo condName="RR" lineID="A" trackID="1" km="4.7" />
</Connector>
<Connector name="" z_real_Ohm="0.001" z_imag_Ohm="0">
<ConductorFrom condName="TSS_5_RF_r" lineID="A" trackID="1" km="5.3" />
<ConductorTo condName="RR" lineID="A" trackID="1" km="5.3" />
</Connector>
These are the connectors to the new negative feeder.
<Connector name="" z_real_Ohm="0.001" z_imag_Ohm="0">
<ConductorFrom condName="TSS_5_NF_l" lineID="A" trackID="1" km="4.7" />
<ConductorTo condName="NF" lineID="A" trackID="1" km="4.7" />
</Connector>
<Connector name="" z_real_Ohm="0.001" z_imag_Ohm="0">
<ConductorFrom condName="TSS_5_NF_r" lineID="A" trackID="1" km="5.3" />
<ConductorTo condName="NF" lineID="A" trackID="1" km="5.3" />
</Connector>
Instead of isolators we now use conductor switches. Remove the Isolators and add the XMLsnippet below.
<Switches>
<ConductorSwitch>
<Switch defaultState="open" name="TSS_5_4.8_CW"
<Position km="4.8" trackID="1" condName="CW" />
</ConductorSwitch>
<ConductorSwitch>
<Switch defaultState="open" name="TSS_5_4.8_MW"
<Position km="4.8" trackID="1" condName="MW" />
</ConductorSwitch>
<ConductorSwitch>
<Switch defaultState="open" name="TSS_5_4.8_NF"
<Position km="4.8" trackID="1" condName="NF" />
</ConductorSwitch>
<ConductorSwitch>
<Switch defaultState="open" name="TSS_5_5.2_CW"
<Position km="5.2" trackID="1" condName="CW" />
</ConductorSwitch>
<ConductorSwitch>
<Switch defaultState="open" name="TSS_5_5.2_MW"
<Position km="5.2" trackID="1" condName="MW" />
</ConductorSwitch>
<ConductorSwitch>
<Switch defaultState="open" name="TSS_5_5.2_NF"
<Position km="5.2" trackID="1" condName="NF" />
</ConductorSwitch>
</Switches>
/>
/>
/>
/>
/>
/>
After we have done the line configuration we need to add and adapt the substations.
First we add the autotransformer station ATS_0 at km 0+000.
<Substation name="ATS_0">
<Autotransformer name="T1" nomPower_MVA="5" nomPrimaryVoltage_kV="55"
nomSecondaryVoltage_kV="27.5" noLoadLosses_kW="5" loadLosses_kW="10"
relativeShortCircuitVoltage_percent="1.8" noLoadCurrent_A="0.2">
<OCSBB bbName="OCS_BB" z_real_Ohm="0.001" z_imag_Ohm="0">
<Switch name="ATS_0_T1_OCS" defaultState="close" />
</OCSBB>
<RailsBB bbName="Rails_BB" z_real_Ohm="0.001" z_imag_Ohm="0">
<Switch name="ATS_0_T1_Rails" defaultState="close" />
</RailsBB>
<NegativeFeederBB bbName="NF_BB" z_real_Ohm="0.001" z_imag_Ohm="0">
<Switch name="ATS_0_T1_NF" defaultState="close" />
</NegativeFeederBB>
</Autotransformer>
<Busbars>
<OCSBB bbName="OCS_BB">
<Connector name="ATS_0_OCS_Feeder" z_real_Ohm="0.001" z_imag_Ohm="0">
<Position condName="CW" lineID="A" trackID="1" km="0" />
</Connector>
</OCSBB>
IFB DD, UM_OPN_51_01.05.03.docx
Page 190 of 232
DMJ, 2014-11-05