Download OpenPowerNet User Manual
Transcript
OPN/51/1.5.3 Page 190 of 232 User Manual Issue 2014-11-05 <ConductorFrom condName="TSS_5_F_r" lineID="A" trackID="1" km="5.3" /> <ConductorTo condName="CW" lineID="A" trackID="1" km="5.3" /> </Connector> <Connector name="" z_real_Ohm="0.001" z_imag_Ohm="0"> <ConductorFrom condName="TSS_5_RF_l" lineID="A" trackID="1" km="4.7" /> <ConductorTo condName="RR" lineID="A" trackID="1" km="4.7" /> </Connector> <Connector name="" z_real_Ohm="0.001" z_imag_Ohm="0"> <ConductorFrom condName="TSS_5_RF_r" lineID="A" trackID="1" km="5.3" /> <ConductorTo condName="RR" lineID="A" trackID="1" km="5.3" /> </Connector> These are the connectors to the new negative feeder. <Connector name="" z_real_Ohm="0.001" z_imag_Ohm="0"> <ConductorFrom condName="TSS_5_NF_l" lineID="A" trackID="1" km="4.7" /> <ConductorTo condName="NF" lineID="A" trackID="1" km="4.7" /> </Connector> <Connector name="" z_real_Ohm="0.001" z_imag_Ohm="0"> <ConductorFrom condName="TSS_5_NF_r" lineID="A" trackID="1" km="5.3" /> <ConductorTo condName="NF" lineID="A" trackID="1" km="5.3" /> </Connector> Instead of isolators we now use conductor switches. Remove the Isolators and add the XMLsnippet below. <Switches> <ConductorSwitch> <Switch defaultState="open" name="TSS_5_4.8_CW" <Position km="4.8" trackID="1" condName="CW" /> </ConductorSwitch> <ConductorSwitch> <Switch defaultState="open" name="TSS_5_4.8_MW" <Position km="4.8" trackID="1" condName="MW" /> </ConductorSwitch> <ConductorSwitch> <Switch defaultState="open" name="TSS_5_4.8_NF" <Position km="4.8" trackID="1" condName="NF" /> </ConductorSwitch> <ConductorSwitch> <Switch defaultState="open" name="TSS_5_5.2_CW" <Position km="5.2" trackID="1" condName="CW" /> </ConductorSwitch> <ConductorSwitch> <Switch defaultState="open" name="TSS_5_5.2_MW" <Position km="5.2" trackID="1" condName="MW" /> </ConductorSwitch> <ConductorSwitch> <Switch defaultState="open" name="TSS_5_5.2_NF" <Position km="5.2" trackID="1" condName="NF" /> </ConductorSwitch> </Switches> /> /> /> /> /> /> After we have done the line configuration we need to add and adapt the substations. First we add the autotransformer station ATS_0 at km 0+000. <Substation name="ATS_0"> <Autotransformer name="T1" nomPower_MVA="5" nomPrimaryVoltage_kV="55" nomSecondaryVoltage_kV="27.5" noLoadLosses_kW="5" loadLosses_kW="10" relativeShortCircuitVoltage_percent="1.8" noLoadCurrent_A="0.2"> <OCSBB bbName="OCS_BB" z_real_Ohm="0.001" z_imag_Ohm="0"> <Switch name="ATS_0_T1_OCS" defaultState="close" /> </OCSBB> <RailsBB bbName="Rails_BB" z_real_Ohm="0.001" z_imag_Ohm="0"> <Switch name="ATS_0_T1_Rails" defaultState="close" /> </RailsBB> <NegativeFeederBB bbName="NF_BB" z_real_Ohm="0.001" z_imag_Ohm="0"> <Switch name="ATS_0_T1_NF" defaultState="close" /> </NegativeFeederBB> </Autotransformer> <Busbars> <OCSBB bbName="OCS_BB"> <Connector name="ATS_0_OCS_Feeder" z_real_Ohm="0.001" z_imag_Ohm="0"> <Position condName="CW" lineID="A" trackID="1" km="0" /> </Connector> </OCSBB> IFB DD, UM_OPN_51_01.05.03.docx Page 190 of 232 DMJ, 2014-11-05