Download Xantech 791-44 Manual
Transcript
INSTALLATION INSTRUCTIONS 791-44 AMPLIFIED CONNECTING BLOCK 791-44 IR IN S TAT U S +12 VDC HIGH IR OUT GND EMITTERS AMPLIFIED CONNECTING BLOCK ® IR RCVR 12 VDC Talk-back LED Fig. 1 Model 791-44 SPECIFICATIONS • 4-screw plug-in terminal for +12VDC, GND, STATUS, & IR IN. • Quick connect "IR RCVR" input (3.5mm mini stereo jack). • Red talk-back LED flashes with IR input signal. • Ten EMITTER output ports, parallel driven (3.5mm mini mono jacks). • HIGH IR OUT port for emitter expansion (3.5mm mini mono jack). See Fig. 5. • Use of included jumpers connect either a 100 or a 470-Ohm resistor in series with each emitter jack for high or low power operation. • 282/283/284/286 series of Emitters may be used in any combination. • Power requirements: 12 volts DC. Uses 781RG or 782-00 Power Supplies (see item 3 below). • 2.1 mm coaxial power jack. • Dimensions: 6" W x 2-1/4" D x 15/16" H INSTALLATION Fig. 2, next page, illustrates a typical installation of a 791-44 in an IR repeater system. A variety of Xantech IR Receivers and a keypad are shown. When configuring a system, please keep the following items in mind: 1. More IR receivers may be wired in parallel, in the same manner as shown, up to a maximum of twelve. More than twelve is not recommended because IR noise picked up by the many IR receivers may cause erratic operation and reduce remote control range. NOTE: This restriction does not apply to Xantech Smart Pads. These may be added virtually without limit, provided power supply requirements are taken into consideration. See item 3. 791-44 1 Modules & Connecting Blocks The Model 791-44 is an Amplified Connecting Block that permits up to 10 single or 10 dual emitters (or any combination thereof) to be driven directly at high or low power levels. Up to 100 emitter ports may be driven using 790-00 passive connecting blocks 'daisy chained' from the HIGH IR OUT port. The 791-44 interfaces all Xantech IR Receivers and Keypads to the emitters along with a power supply in an infrared repeater system. It can also serve to provide emitter expansion at the output port of other Xantech devices, such as the 590 Programmable Controller, the 710 Fone Link™ and the 796 Zone Expander. A floating terminal is provided for "STATUS" line connections. 2. Be sure to connect the +12V, Output and Gnd of each IR receiver and keypad to the respective +12VDC, IR IN and GND of the connecting block as shown. 3. Power Supply Requirements. You may combine many Xantech keypads, IR receivers, controllers and emitters in a system. Having sufficient power supply voltage and current available is critical for proper operation. Be sure to take the following factors into consideration: a) The maximum current for proper operation from a 781RG Power Supply is 120 mA (milliamps). b) The maximum current from a 782-00 Power Supply is 1000 mA. c) Most IR receivers draw 2 mA without signal and 10 mA with signal (check specs. on actual model). d) Each 730 Smart Pad draws 7 mA without signal and 65 mA with signal. e) Each Smart Pad2 or 3 draws 85 mA with or without signal. f) Each emitter draws 3 mA in low power mode and 12 mA in high power mode. g) Add 10 mA for each 794 or 797 Interface module used, if they are powered from the 791-44. h) When using combinations of these devices, add up the currents as shown in the following example. Then choose the power supply or supplies. Do not exceed their maximum current capabilities as noted above! 490-00 Series 480-00 GND IR OUT +12V S +12V 3-Wire Cable IR OUT IR RCVR CB12 Connecting Block 291-10 X Hidden Link™ IR Receiver 780-10 7 Foot Quick Connect Cable J-Box IR Receiver +12V IR OUT Red Stripe 780-10 XANTECH Dinky Link™ IR Receiver +12V 3-Wire Cable ROOM 4 +12V GND J-BOX RECEIVER Micro Link™ IR Receivers ROOM 3 PWR OUT ROOM 2 V G ROOM 1 IR OUT GND GND 490-30 Series Micro Link™ IR Receivers Red Stripe IR OUT Satellite Receiver Amplified Connecting Block Smart Pad2 or 3 GND 791-44 282M Mouse Emitter HIGH IR OUT IR OUT GND ST +12V CAUTION: VCR See text, item 5. IR RCVR 282M Emitter GND S TAT U S IR IN ® 12 VDC For example, the power supply needed for the system shown in Fig. 2 is arrived at as follows: 283M 791- 44 7 Foot 3-Conductor Cable with Quick Connect Stereo Mini Plug AMPLIFIED CONNECTING BLOCK See Item 4 below Laser Disc EMITTERS +12 VDC Blink-IR™ AV Receiver 283M Blink-IR™ CD Changer GND +12 VDC 286M XANTECH 1 2 3 4 5 6 7 8 910 1 2 3 4 5 6 7 8 9 10 ON 794 1 (ON) 0 (OFF) Cassette DecK +12V OUT SENDER/ EMITTER 794-60 Universal Interface UNIVERSAL INTERFACE To 120 VAC (unswitched) Dual Blink-IR™ IR IN b) Assuming a Smart Pad2 or 3 keypad, the with or without signal current is = 85 mA. GND2 Power Supply +12V 781RG GND1 a) The no signal current for the five IR receivers is 5 x 2 = 10 mA. 286M Dual Blink-IR™ Dimmer Control Note: Since only one IR source can operate at a time, the lower current IR receivers (and 730 keypads if used) do not need to have their "with signal" currents included. Makita Drape Controller 282M Mouse Emitter MAIN ROOM, EQUIPMENT CABINET, ETC. Fig. 2 A typical 791-44 System c) The current for one 794 Interface module = 10 mA. d) The current for six emitters is 6 x 3 = 18 mA (in the low power mode. Also the 286 dual emitters count as only one, since they are in series). 2 791-44 e) Now add up all the currents from steps 1 through 4. 10 mA + 85 mA + 10 mA + 18 mA = 123 mA total. Therefore, in this case, one 781RG power supply can be used. NOTE: To avoid current "hogging", never connect regulated supplies, such as the 781RG or the 782-00, in parallel! CAUTION: Do not use unregulated 12V power supply adapters from other manufacturers. These may deliver excessive voltage to the IR receivers and cause them to “latch-up”. When this occurs, the “talk-back” LEDs and 283 Blink IR's (if used) will stay on continuously! 5. The "IR RCVR" jack on the 791-44 allows the 490-30 (and other Xantech IR Receivers outfitted with a 3.5 mm stereo mini plug) to be plugged directly into the 791-44. You can do this when the 791-44 Connecting Block is within reach of the IR receiver's cable -- such as when installing the 490-30 in a cabinet where the controlled equipment is behind closed doors. CAUTION: Plug only Xantech IR Receivers equip-ped with a stereo mini plug into the IR RCVR jack. Do not plug in emitters or other devices. To do so will destroy emitters and damage power supplies! CAUTION For Shielded Wire and Long Lead Lengths When using long lengths (> 50 feet) of inter-room shielded cable, it may be necessary to connect a 470 Ohm 1/8 Watt resistor between IR IN (signal) and GND at the 4-screw terminals of the 791-44. Refer to Fig. 3. The resistor discharges the cable capacitance more quickly, allowing IR codes of high bit rates to pass without data loss for consistent command executions. Ground Shield as shown +12 VDC GND Emitter Output Ports - High and Low Power Settings S TAT U S 791-44 Input Terminals IR IN Shielded Cable(s) The emitter ports are driven in parallel with a choice of 470 Ohm to remote room(s) resistor either a 100 Ohm or a 470 Ohm resistor connected in series with each port. The 100 Ohm choice delivers high Fig. 3 Using a 470 Ohm Capacitance power output and the 470 Ohm setting is lower power. Discharge Resistor The high power setting is achieved by plugging a small jumper (10 are supplied) onto the pair of pins adjacent to the desired emitter port, as shown in Fig. 4 below. The low power option is with the jumper removed. NOTE: The 791-44's are shipped from the factory with the jumpers removed (low power position). Consider the following factors when choosing high or low power modes: 1. In the majority of cases, when you mount an emitter on the IR sensor window of the controlled device, you would use the low power mode (jumpers removed). This prevents overload of high gain sensor circuits and allows proper operation. Emitter Ports Low Power Mode - Jumper Removed Carefully insert jumper on vertical pair of pins when higher power is needed. See note 2 below. High Power Mode - Jumper Installed 791-44 3 Modules & Connecting Blocks 4. For clarity, connections in this illustration are shown going to a 3-conductor bus in a "daisy chain" fashion. In an actual installation, however, it is recommended that 4-conductor "home-runs" be pulled from each room to the 791-44 Connecting Block in the main room. This maintains higher power supply voltage to each IR receiver and keypad for best operation (plus a spare lead). 2. The high power mode may be used in installations where you mount the emitters on an adjacent cabinet wall or door a short distance from the unit's sensor. Another instance is when you place an emitter inside the device, but cannot place it close to the IR sensor. In such cases, you may need the extra power of the high power mode to blast through printed circuit boards or around chassis structures. In addition, when using the lower output 283 and 286 Blink IR's, you may need the high power mode for some devices that have less sensitive IR sensors. 3. The resistors also provide current sharing to each emitter and allow the use of dual emitters in combination with single emitters. You may, therefore, connect any combination of the 282, 283, 284, & 286 series of emitters in the same system, such as that illustrated in Fig. 2, to drive the desired number of devices. When using less than 10 of the emitter ports, you may plug into any of them without regard to order. Emitter Expansion If more than 10 emitter ports are needed, you may daisy chain from the HIGH IR OUT port on the 791-44 to the IN/OUT port on a model 790 passive connecting block as follows: AMPLIFIED CONNECTING BLOCK IR RCVR 790 CONNECTING BLOCK ® ® HIGH HIGH IR OUT OUT HIGH IR IR IN +12 VDC S TAT U S 791-44 GROUND EMITTERS EMITTERS GND You may daisy chain up to a maximum of 9 model 790's for 100 emitter ports total as shown in Fig. 5. Be sure to use an adequate power supply. CAUTION: Never plug emitters directly into the HIGH IR OUT or HIGH IN/OUTports. To do so will destroy the emitters! 12 VDC HIGH IR IN / OUT SIG GND HIGH IR IN / OUT Connect to additional 790's in the same way, if required. Fig. 5 Emitter Expansion Using The "STATUS" Terminal on the 791-44 Fig. 6 illustrates a single zone system where the Status indicator on a Xantech 780-80 IR Receiver and on a Smart Pad2 or 3 in a remote room, shows the ON/OFF status of an A/V receiver. The STATUS and GND terminals on the 791-44 provide convenient tie points for the voltage that drives STATUS indicators on certain Xantech products (such as the 780-80 IR Receiver & Smart Pad2 or 3). To connect such a system, proceed as follows: 1. Unplug all power plugs for the A/V system. 2. Plug a 12V adapter, such as the Xantech 786-00 Power Supply, into a switched AC Outlet on the back of the A/V receiver (or integrated amplifier, preamp, etc.). 3. Cut the attached plug off the 12V adapter and connect the two leads to the STATUS and GND terminals on the 791-44 ("+" to STATUS, "–" to GND). 4. Connect the 4-conductor inter-room cable between the 791-44, the Smart Pad2 or 3 and the 780-80 as shown in Fig.6. 5. If you wish to adjust the brightness of the Status LED on the 780-80, place a resistor in series with the STATUS lead as shown in Fig. 6. Use a value that achieves the desired brightness level (usually 1k Ohm to 10k Ohm, 1/8 watt). NOTE: The brightness of the STATUS LEDs (bank indicators) on the Smart Pad2 or 3 cannot be adjusted! Do not use a resister in series with them! 4 791-44 ROOM 1 IR RCVR S +12V V G 780-80 IR RECEIVER ® +12V STATUS GND IR OUT IR OUT PWR OUT ROOM 2 +12V GND CB12 Connecting Block 291-10 X Hidden Link™ IR Receiver 780-80 7 Foot Quick Connect Cable J-Box IR Receiver STATUS GND IR OUT 490-30 Series Micro Link™ IR Receivers Satellite Receiver Amplified Connecting Block 282M GND STATUS IR OUT +12V HIGH IR OUT Mouse Emitter VCR CAUTION: See text, item 5, Pg 2. IR RCVR 282M Emitter IR IN (+) ® Positive Lead (+) 12 VDC Fig. 6 Using the STATUS terminal in a typical system 283M 791-44 (–) AMPLIFIED CONNECTING BLOCK Add resistor in series with Status line to adjust brightness, if desired. (See step 5, this page). Laser Disc EMITTERS +12 VDC GND S TAT U S Blink-IR™ CD Changer 283M Blink-IR™ Cassette DecK 782-00 Power Supply 283M To 120 V AC (unswitched) Status Voltage (12V @ 10mA) Blink-IR™ AV Receiver 786-00 283M Power Supply Blink-IR™ Mouse Emitter Plug into a Switched AC Outlet on A/V Receiver (see text) MAIN ROOM, EQUIPMENT CABINET, ETC. MOUNTING The 791-44 can be conveniently mounted to a wall or shelf by using the two sheet-metal screws supplied. You may also apply the 4 self adhesive rubber feet (supplied) if you wish to place the unit on a finished surface. The unit may be mounted in any orientation to accommodate the installation. 9-15-00 791-44 5 Modules & Connecting Blocks Smart Pad2 or 3 791-44