Download Coral-i Solutions

Transcript
TLP-3C User Manual
tio
ns
1. Overview
or
2M measurement
l 75Ω and 120Ω line interfaces
C
1)
al
-i
So
lu
2M Transmission Analyzer is a multi-functional and full- featured digital
transmission system test device, designed for the installation test, engineering
check and acceptance, daily maintenance of digital networks, mainly performing
channel test, alarm analysis, fault finding and signalling analysis. In addition,
this instrument further provides various protocol converters with one-way and
bi-directional bit error test function. These capabilities make it ideal for
field use.
——————————————
1
——————————————
TLP-3C User Manual
l HDB3 and AMI line codes
ns
l Out-of-service 2Mb/s, N×64kb/s BER testing
tio
l In-service framed and unframed double-channel testing
So
l Frame data control and monitoring
lu
l “PCM simulator” mode testing
l Timeslot activity monitoring, FAS, N-FAS, TS16MFO analysis
-i
l Built-in 64kb/s tone channel listen capability
al
l CAS and CCS signaling generation and monitoring
or
l Round trip delay measurement
l APS delay measurement
C
l Extensive error and alarm generation
——————————————
2
——————————————
TLP-3C User Manual
l VF tone generation and measurement
ns
l Level measurement
tio
l Pulse mask measurement
lu
l Clock slip measurement
So
l Up to ±999ppm transmit clock deviation
l Clock source: Internal, Interface or External 2M clock/signal
or
2) Datacom measurement
al
-i
l Real-time transmit circuit open/short indication
C
l Datacom (V.24, V.35, V.36, X.21, RS-449, RS-485, EIA-530 and EIA-530A)
interfaces BER Testing
——————————————
3
——————————————
TLP-3C User Manual
l DTE or DCE emulation
lu
l SYNC clock source and sense selection
tio
l SYNC BER testing with data rate 300b/s~8Mb/s
ns
l ASYNC BER testing with baud rate 300b/s~38..4Kb/s
So
l Frequency measurement
al
G.703 CO measurement
or
l G.703 CO 64kb/s BER testing
l Octet timing control and monitoring
Clock source: Internal, Interface selectable
C
3)
-i
l Handshaking signals control and monitoring
——————————————
4
——————————————
4)
Protocol converter measurement
lu
l 2M-G.703 CO SYNC 64kb/s BER testing
tio
l 2M-Datacom SYNC 64k or N×64kb/s BER testing
ns
TLP-3C User Manual
So
l Frequency and offset measurement
l Handshaking signals monitoring
or
Other functions
l Real-time clock
l Test pattern: PRBS, Fixed Code and 16-BIT User Word
C
5)
al
-i
l 2M frame data and alarm monitoring
——————————————
5
——————————————
TLP-3C User Manual
l Error injection: Single and Fixed Rate
ns
l Manual and auto-timer measurement
lu
tio
l ITU-T G.821, G.826, and M.2100 performance analysis
So
6) Optional Teting functions
Jitter measurements to ITU-T standard O.172
or
al
-i
Frequency and offset measurement
C
l
——————————————
6
——————————————
ns
TLP-3C User Manual
tio
2. Appearance
So
lu
2.1 Front Panel
① Status、Alarm LEDs
② LCD Display
-i
③ Speaker
④ Power
al
⑤ Operating Key
C
⑦ Cursor Move Key
or
⑥ Functional Key
——————————————
7
——————————————
TLP-3C User Manual
C
or
al
-i
So
lu
tio
ns
Figure2.1. Front Panel
——————————————
8
——————————————
TLP-3C User Manual
2.1.1 Status,Alarm LED Indicators
ns
As Figure 2.2, the LEDs indicate the port status of Rx1 or DATA.
The LEDs of right side indicate current status,the LEDs which light
tio
green indicate normal conditons,and the LEDs which light red indicate
that any error or alarm conditions occur.When the event finish,the LEDs
lu
are turned off.
The LEDs of left side indicate history record,when the event occur,the
So
correspond LED lights yellow even the event finish,until clear by
al
-i
pressing the key CLR HIS.
POWER
or
C
LED Indicators:
Figure2.2 LEDs Indicator
Power indicator.the LED light green indicates that tester power is supplied by
——————————————
9
——————————————
TLP-3C User Manual
built-in batteries or power charger normally, light red indicates that the power is supplied
by power charger and the built-in batteries is recharging.
Rx1 or DATA Signal status indicator.
FRAME
Rx1 signal Frame indicator
MFRAME
Rx1 signal Multiframe indicator
CRC-4
Rx1 signal structure indicator
PATTERN
Rx1 or DATA signal Pattern indicator
AIS
Rx1 or DATA Alarm Indication Signal indicator
RA
Rx1 signal Remote Alarm indicator
MRA
Rx1 signal Multiframe Remote Alarm indicator
al
-i
So
lu
tio
SIGNAL
ns
by built-in batteries and the power is low,light orange indicates that the power is supplied
CODE ERR Rx1 signal Code Error indicator
Rx1 signal FAS Error indicator
CRC ERR
Rx1 signal CRC Error indicator
C
or
FAS ERR
EBIT ERR Rx1 signal EBit Error indicator
——————————————
10
——————————————
TLP-3C User Manual
PAT SLIP Rx1 or DATA signal pattern slip indicator
Rx1 or DATA signal Bit Error indicator
ns
BIT ERR
LCD Display is made up of three parts, shown as
2
lu
Figure 2.3
tio
2.1.2 LCD Display
So
① Status Display
1
The Status Display part is at the upper side of LCD
Display,day and time is displayed at the right
Figure 2.3 LCD Display
al
-i
side.The icons at the left side indicate the status of tester.
or
The tester power is supplied by built-in batteries,and indicate the left power of the
batteries.
C
The tester power is supplied by power charger.
The tester is not testing.
——————————————
11
——————————————
3
TLP-3C User Manual
The automatic test timer has been set and indicates the timer tester will start the
ns
automatic test testing function at the specified time.
The tester is running test.
tio
Error Code is being injected
When Code Error or Alarm is detected,the speaker will beep out a warning
lu
Viewing saved Setting or Result record
Printing
The keypad is locked,only key
.
al
The screen is locked.
work, you can unlock the keypad by
and key
-i
pressing key
So
Open Com for communication with PC
② Main Display
Function Key and 和
Function Extend Key Display
C
③
or
The Main Display part display test settings and results.
The Function Key Display part is at the buttom of LCD Display, every function key correspond
——————————————
12
——————————————
TLP-3C User Manual
ns
to the function display at the Function Key Display area, the Function Extend Key extend more
is shortcut functional key.
tio
function of the function key.
2.1.3 Speaker
lu
Listen in the channel, the volume can be adjusted at the menu “listen”or “Audio”.
2.1.4 Keypad
So
The Keypad is made up of 4 parts, power key, function key, operating key and cursor move key,
C
or
al
-i
shown as Figure 2.4
Figure 2.4 Keypad
——————————————
13
——————————————
TLP-3C User Manual
Power key
ns
①
Power on or off the tester
Clear History, clear the alarm history.
tio
②Operating key
lu
Error Injection, inject errors when sending signal.
Set/Test switch, switch between Settings and Results interface.
So
Run/Stop, run testing or stop testing.
Escape key, escape to the upper interface, finally return to the main interface
Enter key, perform the F1 key function.
-i
③Functional key
al
Functional Key(short for F key)。The function correspond to the Function
Key Display.
C
or
Function Extend Key, Extend the Function Key.
④Cursor Move Key
——————————————
14
——————————————
TLP-3C User Manual
ns
Move the Cursor towards the direction.
tio
2.2 Back Panel
lu
� Tester Information
� Carrying Case
C
or
al
-i
So
� Reset Hole: Reset the tester
——————————————
15
——————————————
TLP-3C User Manual
3 Side Panel
2.
2.3
2
3
So
lu
tio
1
ns
Figure 2.5 Back Panel
Figure 2.6 Side Panel
-i
① External Power Supply socket.
al
② RS232, communicating with printer or PC
C
or
③ DATACOM,can be switch to various standard interface via switch cable.
——————————————
16
——————————————
2
3
5
4
tio
1
6
-i
So
lu
2.4 Upper Panel
ns
TLP-3C User Manual
Upper Panel
or
al
Figure 2.7
C
② ④ ⑥ Unbalanced interface
——————————————
17
——————————————
ns
TLP-3C User Manual
tio
3. Main Interface
⑴ Power On
C
or
al
-i
So
⑵ Press Escape Key once or more times
lu
You can enter Main Interface by performing below operation
——————————————
18
——————————————
TLP-3C User Manual
ns
Figure 3.1 Main Interface
tio
3.1 Interface select
So
lu
You can enter the follow interface from Main Interface:
Settings
Move the cursor to the place of Settings, press Enter into the Settings Interface. When
-i
the cursor is at the place of Settings, you can set the Work Mode as Normal Test, or Through
al
Test, or Delay Test, or Audio Test, or APS Test by pressing corresponding F key.
Results`
or
Move the cursor to the place of Results, press Enter into the Result interface.when the
cursor is at the place of Results, you can enter the Results, TS Analysis, Listen, G.703
C
interface by pressing corresponding F key.
——————————————
19
——————————————
TLP-3C User Manual
FileMngr
ns
Move the cursor to FileMngr, you can enter the SetMngr or RsltMngr interface by pressing
corresponding F key。
tio
MeterCfg
Move the cursor to MeterCfg, you can set the configration of Display, Printset and
lu
Datetime in this interface.
PC Connect
turn on the connection, and the icon
Update
So
Move the cursor to PC Connect, press Enter or F1 to turn off the connection, press F2 to
is displayed at the Status Display.
C
or
al
-i
Move the cursor to Update, press Enter or F1 to enter the Update introduction interface.
——————————————
20
——————————————
TLP-3C User Manual
ns
3.2 Shortcut
tio
You can enter some main interface from any interface fast,additionally you can perform keypad
lock function by shortcut.
lu
is displayed at the
Function Extend Key area, press
,the left buttom
So
In any interface, when
of the LCD Display will popup a shortcut menu, press
C
or
al
-i
again, the menu disappear.
——————————————
21
——————————————
TLP-3C User Manual
ns
Figure 3.2 Shortcut Menu
tio
Move the cursor to the item in the menu, press Enter or F1 select KeyPad Lock or enter the
So
lu
interface Settings, Results, SetMngr, RsltMngr or MeterCfg.
al
-i
4. Settings
C
or
In this interface, you can set the test items and parameters.
——————————————
22
——————————————
TLP-3C User Manual
tio
It is the
ns
4.1 Tx/Rx1/DATACOM
interface of 2Mbit/s, Tx is on the left
So
lu
side and Rx is on the right side, shown as Figure 4.3.
C
or
al
-i
Figure 4.1 2Mbit/s
——————————————
23
——————————————
TLP-3C User Manual
It is the interface of DATACOM, Tx is on the left side
So
lu
tio
ns
and Rx is on the right side, shown as Figure 4.2.
-i
al
4.1.1 Interface Information
Figue 4.2 DATACOM
Move the cursor to InfcInfo, you can select PrePage, NxtPage or ProSet.this interface is made
C
or
up of 4 parts: Tx/Rx1/DATACOM, Clk/Rx2, OtherSet, PrintSet.
——————————————
24
——————————————
TLP-3C User Manual
Move the cursor to Work Mode,you can select the item below:
ns
4.1.2 Work Mode
Normal Test: Normal Test is used for testing Error Code, Slip, Channel etc.
Audio Test:
tio
Through Test:Set the Work Mode as Through Test.
Set the Work Mode as Audio Test, you can test the Frequency, Level of the TS
Delay Test:
lu
channel.
Test 2Mbit/s, n × 64kbit/s, V interface channel for Round
APS Test:`
So
measurement.
trip delay
APS Test is used for testing Auto Protect Second
-i
4.1.3(Tx)、( Rx)
al
Move the cursor to the Rx,you can select the item below
Rx: Tx is independent of Rx parameter, can be set individually.
or
Rx parameter is same as Tx, when Tx is changed, Rx will be changed as Tx.
C
Rx=Tx:
4.1.4 Interface Mode
——————————————
25
——————————————
TLP-3C User Manual
Move the cursor to the Interface Mode, you can select the item below. The InfcMode of Rx is
2Mbit/s:
ns
same as the one of Tx.
Test 2Mbit/s channel
V.24:
Test V.24 data channel
X.21:
Test X.21 data channel
RS449:
Test RS449 data channel
4.1.5 Signal Form
lu
Test V.35 data channel
So
V.35:
tio
Codirectional 64k:Test 64kbit/s channel
-i
Move the cursor to Signal Form at Tx side, you can set item value below:
Unframed signal form
PCM31:
31 signal form
PCM31CRC:
31 signal form with CRC-4
PCM30:
30 signal form, TS 16 transmit code
PCM30CRC:
30 signal form, TS 16 transmit code with CRC-4
C
or
al
Unframed:
——————————————
26
——————————————
4.1.6 DATA Port
75Ω unbalanced interface.
G.703(120Ω):
120Ωbalanced interface.
lu
G.703(75Ω):
tio
Move the curor to Data Port, you can select the item below:
ns
TLP-3C User Manual
So
4.1.7 Clock Mode
Move the curor to the Clock Mode, you can select the item below:
Clock source is from Internal Clock.
Clock Derived :
Clock source is the clock derived form input signal.
External Clock:
Clock source is from External Clock. External Clock signal is 2.048MHz or
al
-i
Internal Clock:
C
4.1.8 Pattern
or
2.048Mbit/s.
Move the curor to the Pattern of Tx, you can select the item below:
——————————————
27
——————————————
TLP-3C User Manual
2e9-1:
Set Pattern as 2e9-1. As ITU—T0.151 define.
ns
2e11-1: Set Pattern as 2e11-1.
2e15-1: Set Pattern as 2e15-1.。
Set Pattern as 8bit code. When select the item WORD, the function of F1 is set 1, and
or
to move cursor, press F key to set value.
lu
the function of F2 is set 0. press
tio
WORD:
4.1.9 Pattern Porality
-i
Pattern Loss Test are unavailable.
So
Online Test: It is used for 2Mbit/s Error Code Online Test, and Bit Error、Pattern Slip and
al
Move the cursor to Pattern Porality, you can select the item below
The Pattern direction is codirectional as ITU—T0.151 defined.
Inverted:
The Pattern direction is inverted as ITU—T0.151 defined.
C
or
Codirectional:
——————————————
28
——————————————
TLP-3C User Manual
Move the cursor to Wave Form, you can select the item below
Input signal line code is HDB3.
AMI:
Input signal line code is AMI.
tio
HDB3:
ns
4.1.10 Wave Form
lu
4.1.11 Time Slot Select
below
All TS: Press F2 to select All TS.
So
Move the cursor to TS Select, you can select the item
al
form is PCM30CRC or PCM30;
-i
it will set 30 timeslot as test channel while signal
it will set 31 timeslot as test channel while signal
C
or
form is PCM31CRC or PCM31.
——————————————
Figure 4.7 TS Settings
29
——————————————
TLP-3C User Manual
Press F1 to select n*64k, choose any timeslot as test channel.
shown as Figure 4.7。
tio
Perform n*64k select function to enter TS Config interface
ns
n*64k:
lu
Set Timeslot:
Move the cursor to the timeslot you want to set, press F1 to select the timeslot, the
So
timeslot No. is displayed black. Press F2 to deselect the timeslot, the timeslot No. is
display white.press F3 to select all timeslots, press F4 to clear all timeslot. The pattern
Set Timeslot code
al
-i
will be injected into the selected timeslot.
Move the cursor to the bit you want to set in the timeslot code, press F1 to set it 1,
C
or
press F2 to set it 0.
4.1.12 Signal Port
——————————————
30
——————————————
TLP-3C User Manual
Move the cursor to Signal Port, you can select the item below
ns
Terminal:Signal input impedance is 75 Ω or 120Ω.
Bridge: 75Ω或 120Ω.Signal input impedance is high, more than 75 Ω or 120Ω.
tio
Monitor: Signal input impedance is 75 Ω or 120Ω and 26 dB plus for input signal.
lu
4.1.13 Emulation Mode
Move the cursor to Emulation Mode, you can select the item below.
So
DTE:Emulation DTE mode.
DCE:Emulation DCE mode.
-i
4.1.14 Speed
PreSpeed:Speed decrease.
C
or
NxtSpeed:Speed increase.
al
Move the curor to Speed, you can select the item below:
4.1.15 Clock Porality
——————————————
31
——————————————
TLP-3C User Manual
Move the cursor to Clock Porality, you can select the item below:
ns
CoDirect:Clock porality is codirectional.
tio
Inverted:Clock porality is inverted.
4.1.16 Control Signal
Control signal is connected.
Disconnect:
Control signal is disconnectd.
al
-i
So
Connect:
lu
Move the cursor to Control Signal, you can select the item below:
or
4.2 CLK/Rx2 Settings
C
Clk/Rx2 setings is shown as Figure 4.8.
——————————————
32
——————————————
-i
So
lu
tio
ns
TLP-3C User Manual
C
4.2.1 Work Mode
or
al
Figure 4.8 ClK/Rx2 Settings
Move the cursor to Work Mode, you can select the item below.
——————————————
33
——————————————
TLP-3C User Manual
Clock Input: Clk/Rx2 port is set as external clock input, and the Signal Form and Wave Form
Clk/Rx2 port is the second port to perform 2Mbit/s testing.
tio
2M Test:
ns
is unavailable.
4.2.2 Signal Form
lu
Move the cursor to Signal Form at Tx side, you can set item’s value below:
Unframed signal form
PCM31:
31 signal form
PCM31CRC:
31 signal form with CRC-4
PCM30:
30 signal form, TS 16 transmit code
PCM30CRC:
30 signal form, TS 16 transmit code with CRC-4
al
-i
So
Unframed:
4.2.3 DATA Port
G.703(120Ω):
75Ω unbalanced interface.
C
G.703(75Ω):
or
Move the curor to Data Port, you can select the item below:
120Ωbalanced interface.
——————————————
34
——————————————
TLP-3C User Manual
ns
4.2.4 Signal Port
Move the cursor to Signal Port, you can select the item below
tio
Terminal:Signal input impedance is 75 Ω or 120Ω.
lu
Bridge: Signal input impedance is high, more than 75 Ω or 120Ω.
4.2.5 Wave Form
So
Move the cursor to Wave Form, you can select the item below
Input signal line code is HDB3.
AMI:
Input signal line code is AMI.
C
or
al
-i
HDB3:
——————————————
35
——————————————
TLP-3C User Manual
-i
So
lu
tio
ns
4.3 OtherSet
or
4.3.1 Error Code Injection
al
Figure 4.10 OtherSet
None:
C
Move the cursor to Error Code Injection, you can select the item below
No Error Code injection.
——————————————
36
——————————————
TLP-3C User Manual
Bit ERR: Select Bit Error injection, and the injection mode you can select Single or Speed.
ns
the Speed range is 1×10-2~1×10-6.
PAT Slip:
Select PAT Slip injection, and the injection mode you can select Single.
FAS ERR:
Select
Error
injection,
and
single,continuous 2, continuous 3,continuous 4.
the
injection
mode
you
can
select
tio
FAS
lu
While select Error injection, if the injection mode is single, or continuous 2, or continuous
3, continuous 4, then press Key ERR INJ once, 1, or 2, or 3, or 4 Error Codes will be
is displayed for 0.5 second, and then disappears. If the injection
So
injected, and the icon
mode is speed, then press Key ERR INJ once, Error Code is being injected, and the icon
being displaying. Press
4.3.2 Alarm Injection
disappears.
al
-i
Key ERR INJ again, Error Code injection stops, and the icon
or
Move the cursor to Alarm Injection, you can select the item below.
No Alarm injection
AIS:
Select AIS injection
C
None:
——————————————
37
——————————————
is
TLP-3C User Manual
Select RA injection
MRA:
Select MRA injection
tio
RA:
ns
FAS Loss:Select FAS Loss injection
4.3.3 Timing Test
lu
Move the cursor to Timing Test, you can select the item below
Turn off the function of Timing Test.
On:
Turn on the function of Timing Test, and the icon
When the function is on, the icon
is display at Status Area.
is display at Status Area. And when the timer is up,
-i
test will start automatically.
So
Off:
al
4.3.4 Test Time
Move the cursor to Test Time, you can select the item below
Turn off the function of Test Time.
On:
Turn on the function of Test Time
C
or
Off:
When the function is on, and the timer is up, test will stop automatically.
——————————————
38
——————————————
TLP-3C User Manual
ns
4.3.5 Auto Repeat
Move the cursor to Auto Repeat, you can select the item below
Turn off the function of Auto Repeat.
On:
Turn on the function of Auto Repeat.
lu
So
4.4 PrintSet
is off, shown as Figure 4.11.
or
al
-i
means that the function is on, while icon
C
Icon
tio
Off:
——————————————
39
——————————————
lu
tio
ns
TLP-3C User Manual
So
Figure 4.11 PrintSet
4.4.1 Sound Alarm
4.4.2 Print Start
al
Tester beeps when Alarm is detected.
or
Alarm:
-i
ErrCode: Tester beeps when Error Code is detected.
Event:
C
Functions work when test is started.
Print start when error code or alarm event is detected.
——————————————
40
——————————————
TLP-3C User Manual
EndTest: Print start when test end.
ns
Interval:Print start when time interval arrive.
tio
4.4.3 Print Content
Print content include Settings.
ErrCode:
Print content include Error Code results.
Alarm:
Print content include Alarm results.
LineAnal:
Print content include Line Analysis results.
So
lu
Settings:
al
-i
ErrCodeAnal: Print content include all analysis results.
or
5. Professional Setting
C
At Tx/Rx1/DATACOM interface, set InfcMode as 2Mbit/s, set Signal Form of Tx not as Unframed,
——————————————
41
——————————————
TLP-3C User Manual
you can enter this ProSet.
ns
At Settings interface, press ‘ProSet’,enter the professional setting interface.
tio
5.1 Frame Information
lu
Move the cursor to the bit you want to set, press F1 to set it as 1, F2 as 0, shown as Figure
C
or
al
-i
So
5.1.
Figure 5.1 Frame Info
——————————————
42
——————————————
TLP-3C User Manual
Bits that can be set in the Frame Information list below:
ns
Sync Frame Si: Default as 1
Async Frame Si:Default as 1
tio
Async Frame A: Default as 0
Multi Frame Sync Frame y: Default as 0
lu
★ Note: Incorrect setting will make error code or alarm, use default setting to test at
al
-i
5.2 Sync Information
So
normal time.
Move the cursor to the bit you want to modify, press F1 to set it as 1, F2 as 0, F3 set all
C
or
bits in the byte as 1.
——————————————
43
——————————————
So
lu
tio
ns
TLP-3C User Manual
al
5.3 ABCD Setting
-i
Figure 5.2 Sync Info
or
5.3 ABCD SettingMove the cursor to the bit you want to modify, press F1 to set it as 1, F2
C
as 0, F3 set all bits in the byte as 1
——————————————
44
——————————————
lu
tio
ns
TLP-3C User Manual
So
Figure 5.3 ABCD Setting
C
or
al
-i
Note: every ABCD value can not be set as all 0.
——————————————
45
——————————————
TLP-3C User Manual
ns
6. Results
tio
6.1 Normal Test Result
lu
Set the Work Mode in Tx/Rx1/DATA interface as Normal Test or Through Test, the result is
So
Normal Test Result.
6.1.1 Error Code Test Result
al
-i
Error Code Test Result is shown as Figure 6.1.
①Test result info, test time
③Test paramenter
or
②spend time,remained time
C
④Test result content
——————————————
46
——————————————
TLP-3C User Manual
Code Error
%Code ERR:
Pecent of Code Error
FAS ERR:
FAS Error
%FAS ERR:
Pecent of FAS Error
CRC ERR:
CRC-4 Error
%CRC ERR:
Pecent of CRC-4 Error
Ebit ERR:
Ebit Error
%Ebit ERR:
Pecent of Ebit Error
PAT Slip:
Pattern Slip
tio
Code ERR:
lu
Pecent of Bit Error
So
Bit Error
%Bit ERR:
Figure 6.1 Error Code Test Result
C
or
al
-i
Bit ERR:
ns
Test result content:
Set the Interface Mode in Tx/Rx1/DATA interface as Datacom, the result is shown as Figure 6.2.
——————————————
47
——————————————
TLP-3C User Manual
Bit Error
%Bit ERR:
Pecent of Bit Error
PAT Loss:
Pattern Loss
PAT Slip:
Pattern Slip
SIG Loss:
Signal Loss
Freq max:
Frequency Max
Freq min:
Frequency Min
So
lu
tio
Bit ERR:
ns
Results content:
Figure 6.2 Datacom Test Result
or
6.1.2 Alarm Test Result
al
-i
Control Signal
C
Alarm Test Result is shown as Figure 6.3:
——————————————
48
——————————————
TLP-3C User Manual
Signal Loss
AIS:
Alarm Indication Signal
FAS Loss:
FAS Loss
PAT Loss:
Pattern Loss
PWR Loss:
Power Loss
RA:
Remote Alarm
MRA:
Multiple Remote Alarm
Figure 6.3 Alarm Test Result
al
-i
So
lu
tio
SIG Loss:
ns
Result content:
6.1.3 Line Analysis
C
or
The Line Analysis Results are shown as Figure 6.4.
——————————————
49
——————————————
TLP-3C User Manual
Result content:
ns
Clock +Slip: Clock Slip positive
Clock +Cpp:
Clock Slip positive count
Clock -Cpp:
Clock Slip negative count
tio
Clock -Slip: Clock Slip negative
Level -V(V): Line signal pulse negative level
Line signal pulse peak-peak level
So
Level Vp-p(V):
lu
Level +V(V): Line signal pulse positive level
Rx Freq RCV(Hz): Line signal pulse receive frequency
Rx Freq RCV(ppm): Line signal pulse receive frequency ppm
Figure 6.4 Line Analysis
-i
Rx Freq max(Hz): Line signal pulse receive max frequency
al
Rx Freq max(ppm): Line signal pulse receive max frequency ppm
Rx Freq min(Hz): Line signal pulse receive min frequency
C
or
Rx Freq min(ppm): Line signal pulse receive min frequency ppm
——————————————
50
——————————————
TLP-3C User Manual
6.1.4 Results Analysis
ns
Results Analysis include G.821 Analysis, M.2100T Analysis, M.2100K Analysis. G.821 Analysis
tio
is shown as Figure 6.5
Errored Second
%ES(s):
Pecent of Errored Second
SES(s):
Severe Errored Second
%SES(s):
Pecent of Severe Errored Second
AS(s):
Available Second
%AS(s):
Pecent of Available Second
UAS(s):
Unavailable Second
%UAS(s):
Pecent of Unavailable Second
-i
al
G.821 Analysis
or
Figure 6.5
C
G.826 Analysis:
ES(s):
So
ES(s):
lu
G.821 Analysis:
Errored Second
——————————————
51
——————————————
Severe Errored Second
%SES(s):
Pecent of Severe Errored Second
AS(s):
Available Second
%AS(s):
Pecent of Available Second
UAS(s):
Unavailable Second
%UAS(s):
Pecent of Unavailable Second
BBE:
Background Block Error
%BBE:
Pecent of Background Block Error
-i
M.2100T Analysis:
tio
SES(s):
lu
Pecent of Errored Second
So
%ES(s):
ns
TLP-3C User Manual
Errored Second
%ES(s):
Pecent of Errored Second
SES(s):
Severe Errored Second
%SES(s):
Pecent of Severe Errored Second
AS(s):
Available Second
C
or
al
ES(s):
——————————————
52
——————————————
Pecent of Available Second
UAS(s):
Unavailable Second
%UAS(s):
Pecent of Unavailable Second
tio
%AS(s):
ns
TLP-3C User Manual
Errored Second
%ES(s):
Pecent of Errored Second
SES(s):
Severe Errored Second
%SES(s):
Pecent of Severe Errored Second
AS(s):
Available Second
%AS(s):
Pecent of Available Second
UAS(s):
Unavailable Second
%UAS(s):
Pecent of Unavailable Second
C
or
al
-i
So
ES(s):
lu
M.2100K Analysis:
——————————————
53
——————————————
TLP-3C User Manual
ns
6.2 Histogram
tio
Set the Work Mode in Tx/Rx1/DATA interface as Normal Test or Through Test, the result can be
lu
illustated in Histogram.
In Normal Test Results interface, press Histogram
So
Function Key to enter the interface, shown as Figure
C
or
al
-i
6.6.
——————————————
Figure 6.6
54
Histogram
——————————————
TLP-3C User Manual
ns
In Histogram, the horizontal axis is test time, and the vertical axis is the value of
selected event.
tio
Error Code or Alarm type: press F1 or F2 to selct the type of Error Code or Alarm you want to
analyze.
to increase resolution
Press
to decrease resolution
▲: Cursor
Press
-i
to move the cursor to left side by one step
al
Press
So
Press
lu
Resolution:Minimum unit at the horizon time axis in the histogram.
to move the cursor to right side by one step
or
Press F3 to display the previous page content.
C
Press F4 to display the next page content.
Cursor information - time: the time of cursor position, or the begin time of cursor position.
——————————————
55
——————————————
TLP-3C User Manual
ns
Cursor information - result: the error code or alarm of cursor position.
tio
6.3 Audio Test Result
Set the Work Mode in Tx/Rx1/DATACOM interface as Audio Test, and the result will be Audio
Figure 6.6 Audio Test Result
C
Configurable items:
or
al
-i
So
lu
Test result,shown as Figure 6.6.
——————————————
56
——————————————
TLP-3C User Manual
Tx TS: Set the TS that used for testing Audio channel, refer to “Select TS”.
ns
Work Mode: You can select Audio or Listen. When item Listen is selected, no audio signal is
sent out.
tio
Tx Frequency: Set the frequency of selected timeslot signal.
Tx Level: Set the level of selected timeslot signal.
So
Volume control: Adjust the volume of speaker.
lu
Rx TS: Set the TS that used for testing Audio channel, only one can be selected to test.
Test Results:
-i
Rx Frequency:Display frequency result of the selected timeslot.
C
or
al
Rx Level:Display level result of the selected timeslot.
——————————————
57
——————————————
TLP-3C User Manual
ns
6.4 Audio Listen Result
tio
Set the Work Mode in Tx/Rx1/DATACOM interface as Audio Test, and the result will be Audio
Test result,set Work Mode in this result interface as Listen,then the result is Audio Listen
C
or
al
-i
So
lu
Result.shown as Figure 6.7.
Figure 6.7 Audio Listen Result
——————————————
58
——————————————
TLP-3C User Manual
Configurable items:
ns
Rx TS: Set the TS that used for testing Audio channel, only one can be selected to test.
tio
Volume control: Adjust the volume of speaker.
Test Results:
lu
Rx Frequency:Display frequency result of the selected timeslot.
al
6.5 Delay Test Result
-i
So
Rx Level:Display level result of the selected timeslot.
or
Set the Work Mode in Tx/Rx1/DATACOM interface as Delay Test, and the result will be Delay
C
Test result,shown as Figure 6.8.
——————————————
59
——————————————
So
lu
tio
ns
TLP-3C User Manual
al
-i
Figure 6.8 Delay Test Result
Press F1 ‘Start Test’to run testing. If the result is ‘SignalBad’,it means that the
C
‘timeout’.
or
performance of the test line is bad. If Delay time is more than 2.5 second, the result is
——————————————
60
——————————————
TLP-3C User Manual
ns
6.6 APS Test Result
tio
Set the Work Mode in Tx/Rx1/DATACOM interface as APS Test, and the result will be APS Test
Figure 6.9 APS Result
C
or
al
-i
So
lu
result,shown as Figure 6.9.
——————————————
61
——————————————
TLP-3C User Manual
Press F1 ‘Start Test’to run testing,when APS occur,test APS time and display the result.if
tio
ns
APS is more than 2.5 second, the result is ‘timeout’.press F1 again to stop the APS test.
So
lu
6.7 Timeslot Analysis
Set the Work Mode in Tx/Rx1/DATA interface as Normal Test or Through Test, and the Signal
-i
Form of Rx is not unframed, you can view Timeslot Analysis in Results.
al
In the Main Interface, move the cursor to Results position, press TS Analysis functional key
or
to enter this interface. Timeslot Analysis will not affect other ongoing test.
C
Timeslot Analysis results include TS Analysis, Frame Information, Sync Information, ABCD
——————————————
62
——————————————
TLP-3C User Manual
ns
Information, shown as Figure 6.10、Figure 6.11、Figure 6.12 and Figure 6.13.
Timeslot Analysis:
tio
TS : Timeslot No.
BIN : Binary Timeslot value
-i
So
lu
HEX : Hex Timeslot value
al
or
Frame Information:
Figure 6.10 TS Analysis
C
Sync Frame: c0011011, Binary format value of Sync Frame.
Async Frame:i1asssss,Binary format value of Async Frame.
——————————————
63
——————————————
TLP-3C User Manual
-i
So
lu
tio
ns
Multiple Sync Frame: 0000xyxx,Binary format value of Multiple Sync Frame.
Figure 6.12 Sync Information
C
or
al
Figure 6.11 Frame Information
——————————————
64
——————————————
So
lu
tio
ns
TLP-3C User Manual
C
or
al
-i
Figur 6.13 ABCD Information
——————————————
65
——————————————
TLP-3C User Manual
can
see
G.703
displayed
in
the
menu,
tio
In the Main Interface, move the cursor to Reults, you
ns
6.8 G.703 Pulse Mask
press
lu
corresponding F key to enter G.703 interface, shown as
So
Figure 6.14.
Press F1 to start test, press F2 to test overshoot, F3
Figure 6.14 G.703 Pulse Mask
or
Results:
al
-i
to undershoot.
Scope(V) : The peak level of pulse
C
Scope Offset:Offset between peak level of pulse and standard value
——————————————
66
——————————————
TLP-3C User Manual
Width(ns): Time of pulse’s width
ns
Width Offset:Offset between pulse’s width and standard value.
lu
tio
Judgement: Judge the pulse is passed or fail.
So
7. FileManager
-i
7.1 SetManager
al
In the interface of SetManger, Current Setting can be saved to flash, and the saved record
or
can be loaded at any time. Saved records are displayed with parameter as SaveNo.,test tiem
C
and interface mode in the table.
——————————————
67
——————————————
So
lu
tio
ns
TLP-3C User Manual
7.1.1 Default Setting
SetMngr
-i
Figure 7.1
7.1.2 Save Current Setting
al
Move the cursor to CurSet, press F3, will load default setting.
C
7.1.3 Load Setting
or
Move the cursor to CurSet, press F2, will save the current setting to flash
Move the cursor to the record, press F1 to view details, the icon
——————————————
68
is displayed at the
——————————————
TLP-3C User Manual
F2 to load the setting, the current setting is replaced.
7.1.4 Delete record
ns
Status Display area under the condition. And it won’t change the current settings. If press
tio
Move the cursor to the record No. you want to delete, press F3 to delete the record,press F4
lu
to clear all records.
So
7.2 ResultManager
-i
In the interface of ResultManger, Current Result can be saved to flash, and the saved record
al
can be viewed at any time. Saved records are displayed with parameter as SaveNo.,Test Tiem
C
or
and Interface Mode in the table.
——————————————
69
——————————————
So
lu
tio
ns
TLP-3C User Manual
7.2.1 Save Current Result
RsltMngr
-i
Figure 7.2
al
Move the cursor to current result, press F3 to save,and the current result is saved to flash
7.2.2 View Result
or
Move the cursor to the result No. you want to view, press F1 to view setting details, press
C
F2 to view result details,
7.2.3 Delete record
——————————————
70
——————————————
TLP-3C User Manual
Move the cursor to the record No. you want to delete, press F3 to delete the record,press F4
ns
to clear all records.
tio
★ Note: Delete the records you don’t need any more, keep more space if possible to test
So
lu
much more time.
-i
8. Meter Config
al
At Main Interface, move the cursor to MeterCfg, press the corresponding Functional Key to
C
or
enter this interface, shown as Figure 8.1
——————————————
71
——————————————
So
lu
tio
ns
TLP-3C User Manual
Meter Config
al
-i
Figure 8.1
or
8.1 Display Config
C
Contrast:Move the cursor to constrast position, press Functional Key to adjust the constrast.
——————————————
72
——————————————
TLP-3C User Manual
Backlight : Move the cursor to backlight position, press Functional Key to adjust the
ns
backlight.
EverOn: The backlight is always on.
tio
EverOff:The backlight is always off.
Timer:The backlight is lighting on lasting for the time set by timer, until time is up, press
So
lu
any key the backlight light on again.
-i
8.2 Print Config
al
Interface Port Mode: Series Port to connect with printer
Baudrate: set the baudrate that communicate between tester and printer
or
Verify: set the communication verify mode
C
Test Print: test the printer to see if the printer is ready
——————————————
73
——————————————
ns
TLP-3C User Manual
tio
8.3 Daytime Config
C
or
al
-i
So
lu
Config the real time clock of the tester.
——————————————
74
——————————————
ns
TLP-3C User Manual
tio
9. Technique Specification
C
or
al
-i
So
lu
TX:
● Output interface:
75 Ohm balanced, 120 Ohm balanced, conforming to G.703 requirements
● Signal structure:
Unframed
Frame (PCM30, PCM31, PCM30CRC, PCM31CRC), conforming to G.704 n×64 Kbit/s
structure
● Line code:
HDB3 or AMI
● Signal rate:
——————————————
75
——————————————
TLP-3C User Manual
C
or
al
-i
So
lu
tio
ns
2048 kbit/s
● Internal clock accuracy:
≤±10ppm
● Clocking:
Internal, external and distill
● Output intrinsic twittering:
<0.05UI(20Hz-100kHz)
● Test pattern:
False random sequence 2E6-1,2E9-1,2E11-1,2E15-1, 2E20-1, 2E23-1, conforming to
ITU-T0.151, man code 8 bit
● Free TS pattern:
8bit man mode
● Code error insertion:
FAS ERR:once, continuous twice, continuous 3 times, continuous 4 Times
BIT ERR: single 1E-2~1E-7
● Pattern slip:
——————————————
76
——————————————
TLP-3C User Manual
ns
PAT slip
C
or
al
-i
So
lu
tio
RX:
● Signal input impedance:
terminal: 75 Ohm unbalanced, 120 Ohm balanced, Tx loss conforms to G.703
bridge: >750 Ohm unbalanced, >1200 Ohm balanced
monitor:20 dB for input sensibility
● Signal input equalizing feature:
0—9 dB
● Signal input twittering capacity:
conforms to G.823
● Input anti-interference:
conforms to G.703
● Signal structure:
Unframed
——————————————
77
——————————————
TLP-3C User Manual
C
or
al
-i
So
lu
tio
ns
Frame (PCM30, PCM31, PCM30CRC, PCM31CRC), frame signal conforms to G.704 n×64
kbit/s structure
● Line code:
HDB, or AMI
● Signal rate:
2048 kbit ±50ppm
● Test pattern:
False random sequence 2E6-1,2E9-1,2E11-1,2E15-1, 2E20-1, 2E23-1, conforming to
ITU-T0.151, man code 8 bit
● Frequency test:
For line signal and voice channel signal
● Level test:
For line signal and voice channel signal
● Bit error monitoring:
FAS ERR, BIT ERR, CRC-4 code error performance test, CODE ERR
● Alarm monitoring:
——————————————
78
——————————————
TLP-3C User Manual
C
or
al
-i
So
lu
tio
ns
AIS, SIG LOSS, RA, MAR, FAS LOSS, CRC LOSS, PAT LOSS, PAT SLIP
● Slip monitoring:
PAT SLIP, CLK SLIP
● Time delay test:
Test time delay performance
● Bit error analysis:
G.821, G.826, M2100
● External clock input impedance:
Terminal:75 Ohm unbalanced, 120 Ohm balanced, Tx loss conforming to G.703
Bridge:>750 Ohm unbalanced, >1200 Ohm balanced
● External clock input signal:
HDB3/AMI conforming to G.703, pulse signal,>2.5Vp-p
——————————————
79
——————————————
Technique support
lu
Shanghai Grandway Telecom Tech. Co., Ltd
tio
ns
TLP-3C User Manual
C
or
al
-i
So
Address:6F, Xin'an Building, NO.99, Tianzhou Rd,Shanghai, P.R.China.
Tel:+86 21 54451260
Fax::+86 21 54451266
http://www.grandway.com.cn
E-mail:[email protected]
——————————————
80
——————————————