13 Technological Functions Configuration Steps: Leading Axis Module Virtual Position Counter JetWeb The following steps have to be carried out for referencing the leading axis position by means of the leading axis module Virtual Position Counter. Step 1 Action Setting the leading axis position Action: Writing the desired referencing position to R188 "Leading Axis Position" in the leading axis. Result: Leading axis position (R188) in all external following axes shows the referencing position of the leading axis position (R188). 280 Jetter AG