Parameters for all channels
Parameter values
0 to 3
Sensor type
0000: Pt100 (IEC 751)
0001: Pt200 (IEC 751)
0010: Pt400 (IEC 751)
0011: Pt1000 (IEC 751)
0100: Pt100 (JIS)
0101: Pt1000 (JIS)
0110: Pt100 (SAM
0111: Pt1000 (SAM
1000: Ni100
1011: Cu100
1101: 0…30 Ω (mΩ)
1110: 0…300 Ω (10mΩ)
1111: 0…3 kΩ (100 mΩ)
4/5
Filter (PT1)
00:off
01:0.1 s
10:2.6 s
11:29.2 s
6/7
Connection
00:2-wire/ 0 Ω basis
01:2-wire/ 8 Ω basis
01:3-wire
11:4-wire