Download USER MANUAL
Transcript
CA-64 SATEL 21 • The control panel may fail to arm a partition if there is a trouble with the battery or one of the modules (expanders, keypads). • Prior to arming, the control panel may inform the user about the zones violated at the moment of arming, which belong to the selected partitions, and were not preset by the installer as the „Priority” ones. The display will show the „Zones violated 1=Arm 2=Check” message. Press the key [1] to arm the partition, the key [2] to display the list of violated zones, or the [*] key to quit the function without arming. • Prior to arming, the control panel may give a warning message about the troubles occurring in the system. There are some special methods of system arming possible in a partition (available from the LCD keypad): − arm without interior zones – the control panel does not respond to violation of zones defined as internal by the installer. This possibility allows the user to stay in the object and arm. The object is protected externally in normal way, and the system performs all functions programmed. − arm without delayed zones – arming is performed in a way similar to the previous case, but additionally the delayed zones act as immediate ones. To arm the system in one of the presented modes, proceed as follows: 1. Enter ACCESS CODE and press the [*] key. 2. Call the „Arming mode” function. 3. Using the S and T keys select one of the suggested arming modes and press [#]. 4. Call the „Arm” function and select (highlight) the partition to be armed. 5. Press the [#] key. Disarming the partition will cancel the special mode of its arming. To re-arm the partition in a special mode, the procedure described above must be repeated. The procedure of arming the system from a LCD keypad in the partition where the type (10) 24H VIBRATION zone belongs and the testing function of vibration sensors is activated (service setting) is slightly different. When the arming function ([CODE][#] or quick arming [0][#]) is called, the following message appears on the LCD display: „Vibr. zone test xx s (1=arm)” where the xx field indicates the number of seconds before the end of test. During the test, the control panel is waiting for the violation of vibration zones in a given partition. If all the vibration zones of the given zone are violated, the alarm control panel switches over to counting the exit delay time and arming the system. In case some of the vibration zones are not violated during this time, the control panel will display a list of faulty zones (number and name of zone) and will not arm the system. Pressing the digit 1 key during the process of countdown will interrupt the test and arm the system in normal mode, while pressing the [*] key will make it possible to cancel the arming. Arming the system from the partition keypad will bypass the testing of vibration sensors in the particular partition. Also, special control ways of partition status are possible: • partition arming and disarming by means of timers. Timer is an internal control panel logic unit, which measures time. Timer operation is programmed by the service. • partition arming and disarming by means of a “partition user timer”. This timer may be programmed by the user, without necessity of asking the installer (or the service) for