Download HUNT ENGINEERING HERON
Transcript
INTERNAL_SCLK_G = TRUE selects an internal clock source for both ADC’s. =FALSE selects an external clock source for both ADC’s. INTERNAL_SCLK_A = TRUE selects an internal clock source for ADC A. = FALSE selects external clock source for ADC A. INTERNAL_SCLK_B = TRUE selects an internal clock source for ADC B. = FALSE selects an external clock source for ADC B. The table below shows the options that can be selected. N.A. indicates that the state can be either true or false without effecting the system configuration. SLC_G_DOMAIN INTERNAL_SCLK_G INTERNAL_SCLK_A INTERNAL_SCLK_B TRUE TRUE N.A N.A. TRUE FALSE N.A N.A FALSE N.A FALSE FALSE FALSE N.A. FALSE TRUE FALSE N.A. TRUE FALSE FALSE N.A. TRUE TRUE In the case of example1 the ADCs are not used, so the setting of these parameters is not necessary. 4. DAC Clocks The DACs on the HERON-IO5 can have its modes of operation split into two blocks. The first is with the internal Phase Lock Loop (PLL) not operational, this is the case when the DAC comes out of power ON reset. The second is with the internal PLL enabled, which is achieved by writing to registers in the AD9777 DAC over a serial interface. This serial interface is linked to the User FPGA. The ‘User-Apn’ entity has two clocks associated with the DAC data interface, the first is the Source for the DAC Sample Clock (SRC_DAC_SCLK), which is an output from ‘UserApn’ driven with the appropriate frequency for your application. The second clock signal is the DAC Sample Clock (DAC_SCLK) which is an input to the ‘User-Apn’ from the Hardware Interface Layer (H.I.L.), this clock has the correct phase and frequency for interfacing all the DAC logic to the HIL. The maximum input data rate to the DAC’s is 160MHz and the maximum output data rate is 400MHz. When the PLL is enabled interpolation can increase the input to output data rate by up to 8 times making the maximum input data rate (400MHz / 8) = 50MHz. The internal PLL VCO operates within a range of frequencies and this can limit the minimum input data rates. For further information on the possible data rates refer to the AD9777 data sheet. 21 HUNT ENGINEERING HERON-IO5V USER MANUAL