INTERNAL_SCLK_G = TRUE selects an internal clock source for both ADC’s.
=FALSE selects an external clock source for both ADC’s.
INTERNAL_SCLK_A = TRUE selects an internal clock source for ADC A.
= FALSE selects external clock source for ADC A.
INTERNAL_SCLK_B = TRUE selects an internal clock source for ADC B.
= FALSE selects an external clock source for ADC B.
The table below shows the options that can be selected. N.A. indicates that the state can be
either true or false without effecting the system configuration.
SLC_G_DOMAIN
INTERNAL_SCLK_G
INTERNAL_SCLK_A
INTERNAL_SCLK_B
TRUE
TRUE
N.A
N.A.
TRUE
FALSE
N.A
N.A
FALSE
N.A
FALSE
FALSE
FALSE
N.A.
FALSE
TRUE
FALSE
N.A.
TRUE
FALSE
FALSE
N.A.
TRUE
TRUE
In the case of example1 the ADCs are not used, so the setting of these parameters is not
necessary.
4. DAC Clocks
The DACs on the HERON-IO5 can have its modes of operation split into two blocks. The
first is with the internal Phase Lock Loop (PLL) not operational, this is the case when the
DAC comes out of power ON reset. The second is with the internal PLL enabled, which is
achieved by writing to registers in the AD9777 DAC over a serial interface. This serial
interface is linked to the User FPGA.
The ‘User-Apn’ entity has two clocks associated with the DAC data interface, the first is the
Source for the DAC Sample Clock (SRC_DAC_SCLK), which is an output from ‘UserApn’ driven with the appropriate frequency for your application. The second clock signal is
the DAC Sample Clock (DAC_SCLK) which is an input to the ‘User-Apn’ from the
Hardware Interface Layer (H.I.L.), this clock has the correct phase and frequency for
interfacing all the DAC logic to the HIL.
The maximum input data rate to the DAC’s is 160MHz and the maximum output data rate
is 400MHz. When the PLL is enabled interpolation can increase the input to output data
rate by up to 8 times making the maximum input data rate (400MHz / 8) = 50MHz. The
internal PLL VCO operates within a range of frequencies and this can limit the minimum
input data rates. For further information on the possible data rates refer to the AD9777
data sheet.
21
HUNT ENGINEERING HERON-IO5V USER MANUAL