Download Connect Tech CPU Technical data
Transcript
Appendix No. Name (standard in S7T Config) Name (Expert list in S7T Config) Data type min. max. Access Active D P V Description TypeOfAxis.NumberOfData Sets.numberOfDataSets DINT - 0 16 R X X X Number of data records 2001 Configuration Data record TypeOfAxis.NumberOfData changeover. Initialization data Sets.initDataSet record DINT - 0 16 R, W Restart X X X Initialization data record 2002 Configuration Data record changeover. Data record changeover mode TypeOfAxis.NumberOfData Sets.changeMode DINT Enum ChangeMode - - - R, W Restart X X X Data record changeover mode 2010 Mechanical stop limits. Follow-up error TypeOfAxis. NumberOfDataSets.DataSet_x. ClampingMonitoring. followingErrorDeviation REAL 1-16 0.0 1E+12 R, W Immediately X X Definition of the necessary dynamic follow-up error for the detection of the mechanical stop position 2011 Mechanical stop limits. Position tolerance TypeOfAxis. NumberOfDataSets.DataSet_x. ClampingMonitoring. positionTolerance REAL 1-16 0.0 1E+12 R, W Instantaneously X X Permitted setpoint/actual value offset in clamped state 2012 Mechanical stop limits. Mode of mechanical stop position detection TypeOfAxis. NumberOfDataSets.DataSet_x. ClampingMonitoring .recognitionMode DINT Enum Recognition Mode 1-16 - R, W Restart X X Torque monitoring activation method 2020 Mechanical.Load gear. Load rotations TypeOfAxis.NumberOfData Sets.DataSet_x.Gear denFactor DINT 1-16 0 2147483647 R, W Restart X X X Gear ratio nominator 2021 Mechanical.Load gear. Motor rotations TypeOfAxis.NumberOfData DINT Sets.DataSet_x.Gear. numFactor - 0 2147483647 R, W Restart X X X Gear factor denominator 2031 Position control.Static controller data.PV controller.DSC activation TypeOfAxis. NumberOfDataSets. DINT DataSet_x. ControllerStruct. EnumYesNo PV_Controller. enableDSC 1-16 - 2032 Position control.Static controller data.PV controller.Weighting factor TypeOfAxis. NumberOfDataSets. REAL DataSet_x. ControllerStruct. PV_Controller. kpc 1-16 0.0 2033 Position control.Static controller data.PV controller.kp TypeOfAxis. NumberOfDataSets. REAL DataSet_x. ControllerStruct. PV_Controller. kv 1-16 0.0 2034 Position control.Static controller data.PV controller.Activation of the precontrol TypeOfAxis. NumberOfDataSets. DINT DataSet_x. ControllerStruct. EnumYesNo PV_Controller. preCon 1-16 - 2000 Configuration Data record changeover. Number of data records CPU 317T: Technology Functions A5E00251798-03 Index - - - R, W Restart X X Enable DSC 150.0 R, W Immediately X X Precontrol weighting 1E+12 R, W Immediately X X Pcontroller gain R, W Restart X X Enable pre-control - A-39
Related documents
Caractéristiques de la CPU 315-2DP
Connect Tech CPU Technical data
SIMOTION SCOUT - Industry Support Siemens
RIDGID R3121 Technical data
USER MANUAL MC-02A4
Bien débuter son développement pour ArcGIS, Partie 2
Connect Tech CPU Technical data
PACMotion Multi-Axis Motion Controller, IC695PMM335
Anleitung Powerlink
LabVIEW Execution Trace Toolkit User Guide
Traditional NI-DAQ (Legacy) User Manual
Software Engineering – 1 (CS504)