Download RAD Data comm Optimux-34 Specifications
Transcript
Order from: Cutter Networks Chapter 4 Supervisory Port Software Configuration 4.1 Introduction The Optimux-XLT1 parameters can be configured from a supervisory terminal connected to the unit's CONTROL/MNG connector. Remote management is also possible using the Telnet communication protocol through the unit’s MNG-ETH connector. Note All the example screens shown in this chapter are for different hardware/software situations that are available. 4.2 Accessing and Exiting the Supervisory Terminal ➤ To access the supervisory terminal for configuration: 1. Connect an ASCII ANSI terminal, or a PC capable of emulating an ASCII ANSI terminal, to the 25-pin CONTROL/MNG connector on the rear panel of the Optimux-XLT1 (for the cable wiring diagram, refer to the Control Cable Wiring figure). 2. Set the terminal communication parameters to: 19,200 baud, 8 bits/character, one stop bit and no parity bit. Optimux-XLT1 automatically detects and adapts itself to terminal baud rates of 9600, 19200, 38400, 57600 and 115200 bps only. 3. Turn the unit on and immediately press <Enter> four or more times. If the correct baud rate was detected, dots will start to appear correctly on the terminal screen. 4. Press the dot <.> key once to set the parity and to complete the detection. This baud setting will be saved in non-volatile RAM. If the auto-detection fails, the baud rate of the Optimux-XLT1 management port is the last baud rate that was written in the non-volatile RAM. 5. If a PC is used, run a terminal emulation program. 6. Reset the Optimux-XLT1 or turn it ON. The Optimux-XLT1 Main Menu appears. Accessing and Exiting the Supervisory Terminal Ph:727-398-5252/Fax:727-397-9610 4-1 www.bestdatasource.com