Storage Problems Mass storage device problems at startup are usually indicated by read fail messages or by the omission of storage devices from the show config display. Table 8-7 and Table 8-8 list suggestions for troubleshooting storage problems. Table 8-7 Troubleshooting Fixed-Media Problems Symptom Problem Action Fault indicator light for drive is on (amber). Drive has failed. Replace drive. Drives are missing from the show config display. Duplicate SCSI IDs (when removable-media bus is extended to StorageWorks shelf). Correct removable-media SCSI device IDs. May need to reconfigure internal StorageWorks backplane. Drives appear intermittently in SCSI bus length limit exceeded. Check cabling. show config display. Valid drives are missing from the show config display. One drive may appear seven times on the configuration screen display. SCSI ID is set to 7 (reserved for Correct SCSI IDs. host ID). Duplicate host IDS on a shared bus. Change host ID through the pk*0_host_id environment variable (set pk*0_host_id). For systems using Windows NT, choose "Set default configuration" from the Setup menu to select the host ID. You cannot access the software The SCSI ID of the drive is not or data on the drive. unique or the SCSI drive cables are connected incorrectly. The SCSI drive is faulty. See Chapter 6, "Configuring" for information SCSI device configuration display. If the device is not listed in the display, check the SCSI cabling and the drive's SCSI ID. Contact your service representative. Activity indicators do not come Missing or loose cables. on. Remove device and inspect cable connections. Drive is missing from the show config display. Reseat drive on StorageWorks shelf. 8-12 • Troubleshooting Drive is not properly seated on StorageWorks shelf. AlphaServer 1000A Owner's Guide