Transcript
Installing Hardware Options Asynchronous Communication Options The VAX 4000 108 system supports two different asynchronous communications options. These options are as follows: • DHW42-BB -- This asynchronous option provides 16 asynchronous DEC423 dataline-only communications lines through two system ports. You can connect up to 16 peripherals using the MMJ ports on two harmonicas (H3104) that connect to the option cables (BC16C-10). Use the following cables instead of the BC16C-10 cable if you require longer cable lengths: BC16C-25, BC16C-50, BC16C-A0, or BC16C-B5. Use the following cables between the harmonica (H3104) and the DEC423 peripheral: BC16E-10, BC16E-25, or BC16E-50. • DHW42-CB -- This asynchronous option provides eight asynchronous EIA-232 modem control lines through two system ports using two breakout cables (BC29J-06). Attach one of the following cables to a connector on the breakout cable if you require longer cable lengths: BC22F-10, BC22F-25, or BC22F-50. The peripheral you are using may require a null-modem extension cable. See the peripheral documentation or contact your Digital sales representative for information on the correct null-modem cable to use. Installing the Asynchronous Communication Option The VAX 4000 108 system supports two different asynchronous communications options, DHW42-BB and DHW42-CB in the top slot of the I/O receiver. To install either of these, follow these instructions: 1. Turn off the system, unplug the power cord and remove the cover. 2. Insert the module into the top slot of the I/O receiver, pressing it firmly into place to seat the connection. VAX 4000 Model 108 User Information 3–19