Download Custom WaveView User Guide
Transcript
Chapter 9: Measurements Using the Measurement Tool The following parameters can be set for the Overshoot measurement: Parameter Description Percentage Locks the rise/fall margin threshold at the specified high ( H(%) ) and low ( L(%) ) percentages. In signal Y units. Signal Level Locks the rise/fall margin threshold at the specified high ( H(V) ) and low ( L(V) ) signal levels. In signal Y units. Target Signal Uses the min/max Y levels from the signal you are currently measuring. This option is only available when specifying a rise/ fall margin that is locked at a specified percentage range. All Signals Uses the min/max Y levels from all signals that are currently open. This option is only available when specifying a rise/fall margin that is locked at a specified percentage range. User Specified Uses the min/max Y values you specify in the Min and Max text fields. Absolute Specifies the result as "maximum value-high level value." Percentage Specifies the result as a percentage of "absolute value/(high level-low level)." Rise/Fall Time Calculates the risetime and falltime between specified upper and lower levels of a waveform. Note: This measurement is only supported in Analog X-Y waveview panels. The following parameters can be set for the Rise/Fall Time measurement: Parameter Description Percentage Locks the rise/fall margin threshold at the specified high ( H(%) ) and low ( L(%) ) percentages. In signal Y units. Signal Level Locks the rise/fall margin threshold at the specified high ( H(V) ) and low ( L(V) ) signal levels. In signal Y units. Custom WaveView User Guide F-2011.09-SP1 93