Download PDF - QuickSilver Controls, Inc.

Transcript
Data Register Commands
Write Register, Program Mode (WRP)
Description:
The Write Register command writes the included data into the selected 32-bit Data Register.
This command is similar to Write Register, Immediate Mode except it is designed to be
embedded in a program and cannot be use through the serial interface while a command or
program is being executed.
Command Info:
Command Name
Command
Type/Num
Parameters
Param Type
Parameter Range
Write Register,
Program Mode
(WRP)
Program
Class D
Data Register
U16
Standard Register
Range
154 (0x9A)
4 words
Data
Example:
S32/U32
0 to 4,294,967,295
or
-2,147,483,648 to
+2,147,483,647
QuickControl Example:
Write the number “1” to data
register #10.
@16 154 10 1 (CR)
SilverMax Response:
ACK only
SilverMax Command Reference
166
Revision 4.01