Data Integrity 12.2 Detecting Failed Drives 12.2.1 Auto Rebuild on Drive Swap Check Time Go to: View and Edit Configuration Parameters > Drive-Side Parameters > Auto Rebuild on Drive Swap NOTE When this option is enabled, it consumes a little portion of system resource by constantly checking drive buses. The "Auto Rebuild on Drive Swap” timeout is enabled by choosing a time value. The RAID controller will poll all connected drives through the controller’s drive channels at the assigned interval. Drive removal will be detected even if a host does not attempt to access data on that specific drive. If the "Auto Rebuild on Drive Swap" timeout is set to "Disabled" (the default setting is "Disabled"), the controller will not be able to detect any drive removal that occurs after the controller initialization process. The controller will only be able to detect drive removal when host access is directed to the drive side. The “Auto Rebuild on Drive Swap” check time is the interval at which the controller checks to see if a failed drive has been swapped. When a member of a logical drive fails, the controller will continuously scan the drive bus (at the selected time interval). Once the failed drive has been swapped with a drive that has the adequate capacity to rebuild the logical drive, the rebuild will begin automatically. The default setting is “15 seconds,” meaning that the controller will automatically scan the drive busses if a failed drive has been replaced. select a time interval. 225 To change the timeout,