TRIGger:A:BUS:B1:MIL1553B:TIMe:MORELimit 80.0000e-6 would set
either the remote terminal response time (RT) or the inter-message gap (IMG) to
be used in the trigger to 80.0 μS.
TRIGger:A:BUS:B1:MIL1553B:TIMe:MORELimit? might return
100.0000e-6, indicating that the RT or IMG has been set to 100.00 μS.
TRIGger:A:BUS:B<x>:MIL1553B:TIMe:QUALifier
When the MIL-STD-1553 bus trigger condition is set to TIMe, this command
specifies the trigger data time qualifier. (This includes a smaller set of arguments
than other qualifier commands.)B<x> is the bus number, which is 1 or 2.
Conditions
This command requires a DPO3AERO application module.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:MIL1553B:TIMe:QUALifier
{LESSthan|MOREthan|INrange|OUTrange}
TRIGger:A:BUS:B<x>:MIL1553B:TIMe:QUALifier?
Related Commands
TRIGger:A:BUS:B<x>:MIL1553B:CONDition
TRIGger:A:BUS:B<x>:MIL1553B:TIMe:LESSLimit
TRIGger:A:BUS:B<x>:MIL1553B:TIMe:MORELimit
Arguments
LESSthan sets the Time qualifier to less than minimum.
MOREthan sets the Time qualifier to greater than maximum
INrange sets the Time qualifier to inside range.
OUTrange sets the Time qualifier to out of range.
Examples
TRIGger:A:BUS:B1:MIL1553B:TIMe:QUALifier LESSthan sets the Time
qualifier to less than minimum.
TRIGger:A:BUS:B1:MIL1553B:TIMe:QUALifier? might return
OUTRANGE.
2-520
MSO3000 and DPO3000 Series Programmer Manual